Processor
|
Number |
Up to two |
Architecture |
360- or 450-MHz UltraSPARC[tm]-II |
Memory management |
MMU with 64 I-TLB entries and 64 D-TLB entries, 8192
hardware-supported contexts |
Cache memory |
16-KB data and 16-KB instruction on chip per processor
4-MB external per processor
|
UPA Speed |
112.5 MHz |
Main Memory
|
Capacities |
16 DIMM module slots
Install SIMMs in sets of four. 64-, and 128-MB DIMM expansion
128 MB to 2 GB total memory capacity (with 128-MB DIMMs, in pairs)
|
Memory type |
60-ns memory modules |
Datapath |
576 bits wide |
Standard
|
Ethernet |
One ethernet/fast ethernet (10BASE-T/100BASE-T) twisted-pair standard
connector (RJ-45) or
one MII for external
transceiver connection |
Keyboard and mouse |
One standard keyboard/mouse port (mini
DIN-8) |
Parallel |
One Centronics compatible parallel port (DB25);
ECP mode capable |
PCI |
Four full-size slots compliant with PCI specification version 2.1:
- One slot operating at 33- or 66-MHz, 32- or 64-bit data bus width,
3.3 volt
- Three slots operating at 33 MHz, 32- or 64-bit data bus width, 5 volt
|
SCSI |
One 40MB/sec, 68-pin
,Ultra SCSI (SCSI-3), 2 channels (synchronous) |
Serial |
Two RS-232C/RS423 serial ports (DB25) |
Internal Mass Storage
|
Disks |
Up to two 3.5-x 1-in or x 1.6-in. hot-pluggable disks;
9.1-GB, 18.2-GB, or 36.4-GB |
CD-ROM/DVD-ROM |
32x 644-MB SCSI CD-ROM
10X DVD-ROM
|
Tape |
Optional 12-to 24-GB DDS-3 4mm; 20-to 40-GB 8-mm |
Environment
|
AC input |
100 - 240 VAC, 47 - 63 Hz, 6.3 A(max) |
Input power |
610 W |
Heat output |
2080 BTU/hr |
Temperature1 |
Operating: 5° C to 35deg; C (41deg; F to 95deg; F)
Nonoperating: -20deg; C to 60deg; C (-4deg; F to 140deg; F) |
Humidity |
Operating: 20% to 80% relative humidity, noncondensing
Nonoperating: 5% to 93% relative humidity, noncondensing |
Altitude |
Operating: 3000 m (10,000 ft.)
Nonoperating: 12,000 m (40,000 ft.) |
Vibration |
Operating: 0.2G peak, 5 - 500 Hz (swept sine)
0.0002 G2/Hz, 5 - 500 Hz (random)
vertical axis only (castered configuration), vertical and horizontal axes
(foot glide configuration)
Nonoperating: 1G peak, 5 - 500 Hz (swept sine)
0.002 G2/Hz, 5 - 500 Hz (random)
3 perpendicular axes |
Shock |
Operating: 4G peak, 11 milliseconds half-sine pulse
Nonoperating: 15G peak, 11 milliseconds half-sine pulse |
Number of Cords |
1 per power supply; 2 (max) |
Plug Type - U.S. |
NEMA 5-15P |
Plug Type - International |
IEC 320, 10 A, 250 VAC |
1 The front and
rear doors of the cabinet must be 63% open for adequate air flow. |
Regulations
Meets or exceeds the following requirements:
|
Safety |
UL 1950, UL Canada C22.2 No. 950, TUV EN 60950, UL CB Scheme to IEC 950
with full deviations |
RFI/EMI |
FCC Class A, DOC Class B, VCCI Class A, EN 55022 Class B |
Immunity |
EN 50082-1 |
X-ray |
DHHS 21 Subchapter J; PTB German X-ray Decree |
Dimensions and Weights
|
Height |
17.8 cm (7.0 in.)
43.8 cm (17.25 in.) shipping |
Width |
43.8 cm (17.25 in.)
60.02 cm (23.63 in.) shipping |
Depth |
69.2 cm (27.25 in.)
93.98 cm (37.0 in.) shipping |
Weight |
29.5 kg (65 lb.)
38.6 kg (85 lb.) shipping |
Power cord |
1.99 m (6.56 ft.) |
Clearance
and Service Access |
Front1 |
91.4 cm (36 in.) |
Rear1 |
91.4 cm (36 in.) |
Right1 |
91.4 cm (36 in.) |
Left1 |
91.4 cm (36 in.) |
Top1 |
91.4 cm (36 in.) |
Airflow |
|
1These
specifications refer to a sytem that is fully extended from the rack for
service. When in normal operation, there are no side clearance requirements
for the server as the air flow is from the front to rear. However, make
sure that any front or back cabinet doors are 63% open to allow adequate
airflow. This can be accomplished by removing the doors, or ensuring that
the doors have a perforated pattern that provides a 63% open area. See 816-1613
for more details. |
Rack
Mounting |
Fits into a standard commercial 19-inch wide, 36-inch deep
rack |