Sun Microsystems, Inc.
spacer spacer
spacer   Sun System Handbook Home | Systems | Components | General Info | Search | Feedback 
spacer
black dot
 
black fade
 

Sun Enterprise[tm] 220R Server: Hardware Specifications

Processor
Number Up to two
Architecture 360- or 450-MHz UltraSPARC[tm]-II
Memory management MMU with 64 I-TLB entries and 64 D-TLB entries, 8192 hardware-supported contexts
Cache memory

16-KB data and 16-KB instruction on chip per processor

4-MB external per processor

UPA Speed 112.5 MHz
Main Memory
Capacities

16 DIMM module slots

Install SIMMs in sets of four. 64-, and 128-MB DIMM expansion

128 MB to 2 GB total memory capacity (with 128-MB DIMMs, in pairs)

Memory type 60-ns memory modules
Datapath 576 bits wide
Standard
Ethernet One ethernet/fast ethernet (10BASE-T/100BASE-T) twisted-pair standard connector (RJ-45) or one MII for external transceiver connection
Keyboard and mouse One standard keyboard/mouse port (mini DIN-8)
Parallel One Centronics compatible parallel port (DB25); ECP mode capable
PCI

Four full-size slots compliant with PCI specification version 2.1:

  • One slot operating at 33- or 66-MHz, 32- or 64-bit data bus width, 3.3 volt
  • Three slots operating at 33 MHz, 32- or 64-bit data bus width, 5 volt
SCSI One 40MB/sec, 68-pin ,Ultra SCSI (SCSI-3), 2 channels (synchronous)
Serial Two RS-232C/RS423 serial ports (DB25)
Internal Mass Storage
Disks Up to two 3.5-x 1-in or x 1.6-in. hot-pluggable disks; 9.1-GB, 18.2-GB, or 36.4-GB
CD-ROM/DVD-ROM

32x 644-MB SCSI CD-ROM

10X DVD-ROM

Tape Optional 12-to 24-GB DDS-3 4mm; 20-to 40-GB 8-mm
Environment
AC input 100 - 240 VAC, 47 - 63 Hz, 6.3 A(max)
Input power 610 W
Heat output 2080 BTU/hr
Temperature1 Operating: 5° C to 35deg; C (41deg; F to 95deg; F)
Nonoperating: -20deg; C to 60deg; C (-4deg; F to 140deg; F)
Humidity Operating: 20% to 80% relative humidity, noncondensing
Nonoperating: 5% to 93% relative humidity, noncondensing
Altitude Operating: 3000 m (10,000 ft.)
Nonoperating: 12,000 m (40,000 ft.)
Vibration Operating: 0.2G peak, 5 - 500 Hz (swept sine)
0.0002 G2/Hz, 5 - 500 Hz (random)
vertical axis only (castered configuration), vertical and horizontal axes (foot glide configuration)
Nonoperating: 1G peak, 5 - 500 Hz (swept sine)
0.002 G2/Hz, 5 - 500 Hz (random)
3 perpendicular axes
Shock Operating: 4G peak, 11 milliseconds half-sine pulse
Nonoperating: 15G peak, 11 milliseconds half-sine pulse
Number of Cords 1 per power supply; 2 (max)
Plug Type - U.S. NEMA 5-15P
Plug Type - International IEC 320, 10 A, 250 VAC
1 The front and rear doors of the cabinet must be 63% open for adequate air flow.
Regulations
Meets or exceeds the following requirements:
Safety UL 1950, UL Canada C22.2 No. 950, TUV EN 60950, UL CB Scheme to IEC 950 with full deviations
RFI/EMI FCC Class A, DOC Class B, VCCI Class A, EN 55022 Class B
Immunity EN 50082-1
X-ray DHHS 21 Subchapter J; PTB German X-ray Decree
Dimensions and Weights
Height 17.8 cm (7.0 in.)
43.8 cm (17.25 in.) shipping
Width 43.8 cm (17.25 in.)
60.02 cm (23.63 in.) shipping
Depth 69.2 cm (27.25 in.)
93.98 cm (37.0 in.) shipping
Weight 29.5 kg (65 lb.)
38.6 kg (85 lb.) shipping
Power cord 1.99 m (6.56 ft.)
Clearance and Service Access
Front1 91.4 cm (36 in.)
Rear1 91.4 cm (36 in.)
Right1 91.4 cm (36 in.)
Left1 91.4 cm (36 in.)
Top1 91.4 cm (36 in.)
Airflow
1These specifications refer to a sytem that is fully extended from the rack for service. When in normal operation, there are no side clearance requirements for the server as the air flow is from the front to rear. However, make sure that any front or back cabinet doors are 63% open to allow adequate airflow. This can be accomplished by removing the doors, or ensuring that the doors have a perforated pattern that provides a 63% open area. See 816-1613 for more details.
Rack Mounting
Fits into a standard commercial 19-inch wide, 36-inch deep rack

WebToneWebToneWebToneWebTone
 Copyright 1994-2003 Sun Microsystems, Inc.,  901 San Antonio Road, Palo Alto, CA 94303 USA.  All rights reserved.
 Legal Terms Privacy Policy Feedback