Document fins/I0596-1


FIN #: I0596-1

SYNOPSIS: New NVRAM may be incompatible with Ultra 5/10 motherboards and some
          Ultra 5/10 motherboards may be incorrectly labeled.

DATE: Jun/28/00

KEYWORDS: New NVRAM may be incompatible with Ultra 5/10 motherboards and some
          Ultra 5/10 motherboards may be incorrectly labeled.


---------------------------------------------------------------------
- Sun Proprietary/Confidential: Internal Use Only -
---------------------------------------------------------------------  
                            FIELD INFORMATION NOTICE
                  (For Authorized Distribution by SunService)



SYNOPSIS:  New NVRAM may be incompatible with Ultra 5/10 motherboards 
           and some Ultra 5/10 motherboards may be incorrectly labeled. 
              

TOP FIN/FCO REPORT: No 
 
PRODUCT_REFERENCE:  Ultra 5/10 NVRAM and Motherboard labeling   
 
PRODUCT CATEGORY:   Desktop / System Board 

PRODUCTS AFFECTED:  
  
Mkt_ID   Platform   Model   Description   Serial Number
------   --------   -----   -----------   -------------
Systems Affected
----------------
  -        A21       ALL     Ultra 5            -
  -        A22       ALL     Ultra 10           -

X-Options Affected
------------------
  -         -         -          -              -

PART NUMBERS AFFECTED: 

Part Number    Description                       Model
-----------    -----------                       -----
375-0079-XX    ASSY,OEM,BOARD                      -
375-0115-XX    ASSY,OEM,BOARD                      -
525-1817-XX    PGRM,TOD,48T59Y-70PC1SM,70NS,W      -


REFERENCES:
 
ECO:  WO_17476 

    
PROBLEM DESCRIPTION: 

This FIN is intended to inform about incompatibility problems with
using new NVRAM on the current Ultra 5/10 motherboard.  Distributing
this information will help support engineers to plan ahead and avoid
the incompatibility problem.

PROBLEM 1

The new NVRAM part number 525-1817-0X cannot be used on the
current Ultra 5/10 motherboard part number 375-0079-04.  Due to this
incompatibility, a new part number 375-0115-0X has been created for the
new Ultra 5/10 motherboard containing the new NVRAM prom assembly.

PROBLEM 2

Mislabeling issue; Approximately 1,200 (375-0115-0X) motherboards were
manufactured with new NVRAM part number 525-1817-0X .  These
motherboards were incorrectly labeled as 375-0079-0X.  The mislabeled
boards are NOT electrically or functionally defective.
 
Above problem has been risen because the Sun manufacturing vendor, 
Mitac had to switch from AMP socket to Chupond socket for housing the
NVRAM as a result of material supply problem.  Consequently a small
number of systems shipped without appropriate Corrective Action
procedures instituted as mentioned above.

The Corrective Action was taken at Sun manufacturing vide the 
ECO WO_17476, which released a Ultra 5/10 new motherboard part
number 375-0115-0X having the new NVRAM part number 525-1817-0X.

Due to the physical characteristics of the new NVRAM , the new NVRAM is
NOT compatible with the old motherboard.  Systems manufactured with the
new OEM motherboard and NVRAM will be identified as such with the
letter "B" following the serial number on the EZ label which is located
on the side of front Bezel. 

 Refer to the following compatibility matrix shown below;
 
 Mother Board  |  NVRAM  |  socket type  |  Old NVRAM  |  New NVRAM
 ------------------------------------------------------------------
 375-0079-XX   |  (old)  |  Amp 	 |  Good       |  Not Good
 375-0079-XX   |  (new)  |  Chupond 	 |  Good       |  Good
 375-0115-XX   |  (new)  |  Chupond      |  Good       |  Good


IMPLEMENTATION: 
 
         ---
        |   |   MANDATORY (Fully Pro-Active)
         ---    
         
  
         ---
        |   |   CONTROLLED PRO-ACTIVE (per Sun Geo Plan) 
         --- 
         
                                
         ---
        | X |   REACTIVE (As Required)
         ---
         

CORRECTIVE ACTION: 

The following recommendation is provided as a guideline for authorized
Enterprise Services Field Representatives and Warranty Customers that
may be encountering the above mentioned problem;

In the event of a service issue requiring Ultra 5/10 motherboard or
NVRAM replacement, Ultra U5/U10 motherboards and NVRAMs should be
replaced as shown on part replacement matrix below.
 
Part Replacement Matrix:

Installed    | Socket Type | Installed NVRAM    |  Replacement   | Remarks
Motherboard  |             |                    |  Motherboard   | 
============ | =========== | ================== |  ============  | =======
F375-0079-0X | Amp         | Old (F525-1430-01) |  F375-0079-0X/ |
             |             |                    |  F375-0115-0X  |    
F375-0079-0X | Chupond     | New (F525-1817-01) |  F375-0115-0X  | Just the
1200
             |             |                    |                | motherboards
F375-0115-0X | Chupond     | New (F525-1817-01) |  F375-0115-0X  |
        

COMMENTS:

--------------------------------------------------------------------------
Implementation Footnote:

iii) For REACTIVE FINs, Enterprise Services will implement the FIN as the   
     need arises.
     
--------------------------------------------------------------------------
All released FINs and FCOs can be accessed using your favorite network 
browser as follows:
 
SunWeb Access:
-------------- 
* Access the top level URL of http://sdpsweb.ebay/FIN_FCO/

* From there, select the appropriate link to query or browse the FIN and
  FCO Homepage collections.
 
SunSolve Online Access:
-----------------------
* Access the SunSolve Online URL at http://sunsolve.Corp/

* From there, select the appropriate link to browse the FIN or FCO index.

Supporting Documents:
---------------------
* Supporting documents for FIN/FCOs can be found on Edist.  Edist can be 
  accessed internally at the following URL: http://edist.corp/.
  
* From there, follow the hyperlink path of "Enterprise Services Documenta- 
  tion" and click on "FIN & FCO attachments", then choose the
appropriate   
  folder, FIN or FCO.  This will display supporting directories/files for 
  FINs or FCOs.
   
Internet Access:
----------------
* Access the top level URL of https://infoserver.Sun.COM
--------------------------------------------------------------------------
General:
--------
* Send questions or comments to finfco-manager@Sun.COM
---------------------------------------------------------------------------
                                                        