24408   Boot cdrom on an Enterprise 450 with 480 MHz CPU Module fails with panic or Fast Data Access MMU Miss   14 Nov 2000

Status Issued

Description

Booting a Solaris 2.5.1 11/97 CDROM on an Enterprise 450 with 480 MHz CPU Module fails with error:
 

Fast Data Access MMU Miss


Booting a Solaris 2.6 FCS through 2.6 HW 5/98 CDROM on an Enterprise 450 with 480 MHz CPU Module fails with error:

 
panic[cpu]/thread=0x10404040: mutex_enter: bad mutex
SOLUTION SUMMARY:

The Enterprise 450 with the 480MHz cpu module are not supported under any version of 2.5.1.

The minimum supported Solaris 2.6 version is HW 5/98. It will install with 02/00 Operating Environment CD because it incorporates kernel patch 105181-19 but will not install with previous OECD versions.

The minimum supported Solaris 7 version is HW 11/99.

INTERNAL SUMMARY:
SUBMITTER: Mark Bennett APPLIES TO: Hardware, Hardware/Ultra Enterprise/Servers/Enterprise 450, OS Install/Boot, OS Install/Boot/OS Install, OS Install/Boot/System Boot ATTACHMENTS: