SRDB ID | Synopsis | Date | ||
24408 | Boot cdrom on an Enterprise 450 with 480 MHz CPU Module fails with panic or Fast Data Access MMU Miss | 14 Nov 2000 |
Status | Issued |
Description |
Booting a Solaris 2.5.1 11/97 CDROM on an Enterprise 450 with 480 MHz CPU Module fails with error:
Fast Data Access MMU Miss
Booting a Solaris 2.6 FCS through 2.6 HW 5/98 CDROM on an Enterprise 450 with 480 MHz CPU Module fails with error:
SOLUTION SUMMARY:
panic[cpu]/thread=0x10404040: mutex_enter: bad mutex
The Enterprise 450 with the 480MHz cpu module are not supported under any version of 2.5.1.
The minimum supported Solaris 2.6 version is HW 5/98. It will install with 02/00 Operating Environment CD because it incorporates kernel patch 105181-19 but will not install with previous OECD versions.
The minimum supported Solaris 7 version is HW 11/99.