SRDB ID   Synopsis   Date
48028   Sun StorEdge [TM] D1000 disk drive led's flashing amber / green continuously   18 Oct 2002

Status Issued

Description

All the disk drives in a D1000 disk array have their led's flashing amber and green continuously.

No other disk problems or errors are evident.

SOLUTION SUMMARY:

If SunVTS [TM] is run against a machine or domain with a D-1000 disk array attached, the D-1000 array may be left in such a state that the disk led's flash amber and green continuously.

There are no other adverse effects, but the D-1000 array must be power cycled to clear this condition.

This is due to the SES driver being left in an unknown state by SunVTS after the diagnostic tests are aborted..

Note: If the D1000 is configured in a split bus configuration and connected to two different hosts, only the disks attached to the host that ran SunVTS will have flashing amber / green leds.

INTERNAL SUMMARY:

michael.buckley@sun.com

SUBMITTER: Michael Buckley APPLIES TO: Hardware/Disk Storage Subsystem/StorEdge Disk Array/StorEdge D1000, AFO Vertical Team Docs/Hardware ATTACHMENTS: