Document fcos/A0097-1


FCO #: A0097-1

SYNOPSIS: Ultra2 200MHz UltraSPARC CPU Modules fail with SRAM and Writeback
          Data Parity Errors

DATE: May/22/98

KEYWORDS: Ultra2 200MHz UltraSPARC CPU Modules fail with SRAM and Writeback
          Data Parity Errors


---------------------------------------------------------------------
        - Sun Proprietary/Confidential: Internal Use Only -
---------------------------------------------------------------------  
                        FIELD CHANGE ORDER
                  (For Authorized Distribution by SunService)

 
SYNOPSIS: Ultra2 200MHz UltraSPARC CPU Modules fail with SRAM and Writeback
          Data Parity Errors.

TOP FIN/FCO REPORT: Yes

PRODUCT_REFERENCE: Ultra2 200MHz UltraSPARC CPU Modules

PRODUCT CATEGORY: Desktop / System CPU Module  

PRODUCTS AFFECTED:

Mkt_ID   Platform   Model   Description                Serial Number
------   --------   -----   -----------                -------------
A14        A14      1200    Ultra Enterprise 2               -
A14        A14      2200    Ultra Enterprise 2               -
X1188A      -         -     Option, 200MHz/1MB module        -
                         
PART NUMBERS AFFECTED:

Part Number              Description
-----------              ----------- 
501-3041-05 (or below)   200MHz Module, 1MB, 5NS, Ultra 2
501-4791-02 (or below)   200MHz Module, 1MB, 5NS, Ultra 2

(SCSI Devices)
Type    Vendor    Model     SerialNumber(Min)    SerialNumber(Max)    Firmware
----    ------    -------   ------------------   ------------------   --------
N/A

REFERENCES:

ECO: WO_12745
LEAP: 870
ECO: WO_12260
ECO: WO_11647
LEAP: 821
LEAP: 824
Purge: WW001#03367
Purge: WW001#03495
Esc: 507884
BugID: 4012566
DPCO: 113

PROBLEM DESCRIPTION:     

Ultra2 systems having 200MHz UltraSPARC CPU Modules may fail with;

   panic[cpu0]/thread=0x507a3da0: CPU0 Ecache SRAM Data Parity Error: 
      AFSR 0x00000000 00408000 AFAR 0x000001ff 30000000

              - or -

   panic[cpu0]/thread=0x507a3da0: CPU0 Ecache SRAM Data Parity Error:
      AFSR 0x00000000 0040C000 AFAR 0x000001ff 30000000
  
              - or -

   panic[cpu0]/thread=0x50965260: CPU0 Writeback Data Parity Error: 
      AFSR 0x00000000 00804000 AFAR 0x000001ff 30000000

Root Cause has been attributed to CPU and SRAM components on the 200MHz Module.

The most recent fix was implemented within manufacturing via ECO# WO_12745
which was approved on March 23, 1998.

IMPLEMENTATION:

         ---
  	|   |  	MANDATORY (Fully Pro-Active)
	 ---    

         ---
  	|   | 	CONTROLLED PRO-ACTIVE (per Sun Geo Plan) 
	 ---   

         ---
        | X |   UPON FAILURE or UPON CUSTOMER REQUEST
         ---	

REPLACEMENT TIME ESTIMATE:   30 minutes

SPECIAL CONSIDERATIONS:

CORRECTIVE ACTION:
  
Upon failure or upon customer request replace 501-3041-05 (and below) or 
501-4791-02 (and below) with 501-4791-03.

COMMENTS:

Compatibility testing has been performed in Ultra 2 systems with mixed 
modules (501-3041-0X cpu0 and 501-4791-03 cpu1 and 501-4791-03 cpu0 and 
501-3041-0X cpu1) with no problems or errors encountered.


BILLING TYPE:

 Warranty: Sun will provide parts at no charge under Warranty 
           Service. On-Site Labor Rates are based on how the
           system was initially installed.

 Contract: Sun will provide parts at no charge. On-Site Labor Rates
           are based on the type of service contract.

 Non Contract: Sun will provide parts at no charge. Installation by
               Sun is available based on the On-Site Labor Rates 
               defined in the Price List.

--------------------------------------------------------------------------
Implementation Footnote:
________________________

i)   In case of Mandatory FCOs, SunService will attempt to contact all known
     customers to recommend the part upgrade.

ii)  For controlled proactive swap FCOs, SunService mission critical support
     teams will initiate proactive swap efforts for their respective accounts,
     as required.

iii) For Replace upon Failure FCOs, SunService partners will implement the
     necessary corrective actions as and when they are required.

--------------------------------------------------------------------------

All released FINs and FCOs can be accessed using your favorite network 
browser as follows:

SunWeb Access: 
______________

* Access the top level URL of http://cte.corp/FIN_FCO/

* From there, select the appropriate link to query or browse the FIN and
  FCO Homepage collections.

Supporting documents for FIN/FCOs can be found on Edist.  Edist can be 
accessed internally at the following URL: http://edist.corp/.
 
* From there, follow the hyperlink path of "SunService Documentation"
and 
  click on "FIN & FCO attachments", then choose the appropriate
folder, FIN or 
  FCO.  This will display supporting directories/files for FINs or FCOs.
  
Internet Access:
_______________

* Access the top level URL of https://infoserver.Sun.COM

--------------------------------------------------------------------------
General:
________

Send questions or comments to finfco-manager@cte.Corp

---------------------------------------------------------------------------


Copyright (c) 1997-2003 Sun Microsystems, Inc.