FCO #: A0124-1

SYNOPSIS: Early life failures on the E10000 System Board could cause system to
          crash

DATE: May/19/98

KEYWORDS: Early life failures on the E10000 System Board could cause system to
          crash


---------------------------------------------------------------------
        - Sun Proprietary/Confidential: Internal Use Only -
---------------------------------------------------------------------  
                        FIELD CHANGE ORDER
                  (For Authorized Distribution by SunService)


SYNOPSIS: Early life failures on the E10000 System Board could cause system
          to crash.

TOP FIN/FCO REPORT: Yes

PRODUCT_REFERENCE: E10000 System Board

PRODUCT CATEGORY: Server/ System CPU

PRODUCTS AFFECTED:

Mkt_ID     Platform   Model   Description                      Serial Number
------     --------   -----   -----------                      -------------
E10000     E10000     ALL     Ultra Enterprise E10000 Server      *See Note
HPC10000   E10000     ALL     Sun HPC 10000 Server                *See Note

*Note: Only shipments made before August 15, 1997 are affected.

PART NUMBERS AFFECTED:

Part Number             Description
-----------             -----------
501-4786-01	        ECB ASSY,SYSTEM BOARD(w/PowerPuck serialnos<607303500P)
501-4347-09(or below)   ECB ASSY,SYSTEM BOARD(w/PowerPuck
serialnos<607303500P)

(SCSI Devices)
Type    Vendor    Model     SerialNumber(Min)    SerialNumber(Max)    Firmware
----    ------    -------   ------------------   ------------------   --------
N/A

REFERENCES:

  ECO: WO_11720
  LEAP: 809

PROBLEM DESCRIPTION:     

On early shipments of E10000 systems (ONLY those shipped prior to August
15, 1997), some System Boards may experience early life failures causing 
domain crashes.

Systems with multiple board domains will reboot with the failing board
removed from the configuration.

Repair analysis has attributed these failures to a DC-DC converter (power 
puck) component that is mounted on the system board.  Vendor analysis has 
determined that failures are because of early life defects (cracked input
capacitors).  

Manufacturing corrective actions were cut-in on August 15, 1997 to screen 
out the affected power puck component.  Consequently E10000 shipments 
after that date will not experience this failure mode.  SunService 
Logistics stock of suspect system boards is being purged to ensure that 
system boards supplied from spares inventory are free of the suspect 
puck component.

Due to the early life nature of this failure mode most of the boards that 
would fail already have.  Of the remaining suspect system boards 1.2% may 
still be subject to failure.  All other power pucks will follow a normal 
1,000,000 hour MTBF curve.

It is specifically recommended that this FCO be an "Upon Failure" FCO 
for the following reasons:

i) There is a greater risk of creating system down time while trying to 
   proactively swap multiple system boards.

ii) For systems shipped before Aug/15/97, most of the boards that would
    fail already have.

IMPLEMENTATION:

         ---
        |   |   MANDATORY (Fully Pro-Active)
         ---    

         ---
        |   |   CONTROLLED PRO-ACTIVE (per Sun Geo Plan) 
         ---   

         ---
        | X |   UPON FAILURE
         ---


REPLACEMENT TIME ESTIMATE:   30 minutes

SPECIAL CONSIDERATIONS:

CORRECTIVE ACTION:     

Upon failure replace

	a) 501-4347-08 or 501-4347-09 with 501-4347-10
or	b) 501-4786-01 with 501-4786-02

BILLING TYPE:

 Warranty: Sun will provide parts at no charge under Warranty 
           Service. On-Site Labor Rates are based on how the
           system was initially installed.

 Contract: Sun will provide parts at no charge. On-Site Labor Rates
           are based on the type of service contract.

 Non Contract: Sun will provide parts at no charge. Installation by
               Sun is available based on the On-Site Labor Rates 
               defined in the Price List.

--------------------------------------------------------------------------
Implementation Footnote:
________________________

i)   In case of Mandatory FCOs, SunService will attempt to contact all known
     customers to recommend the part upgrade.

ii)  For controlled proactive swap FCOs, SunService mission critical support
     teams will initiate proactive swap efforts for their respective accounts,
     as required.

iii) For Replace upon Failure FCOs, SunService partners will implement the
     necessary corrective actions as and when they are required.

--------------------------------------------------------------------------

All released FINs and FCOs can be accessed using your favorite network 
browser as follows:

SunWeb Access: 
______________

* Access the top level URL of http://cte.corp/FIN_FCO/

* From there, select the appropriate link to query or browse the FIN and
  FCO Homepage collections.

Supporting documents for FIN/FCOs can be found on Edist.  Edist can be 
accessed internally at the following URL: http://edist.corp/.
 
* From there, follow the hyperlink path of "SunService Documentation"
and 
  click on "FIN & FCO attachments", then choose the appropriate
folder, FIN or 
  FCO.  This will display supporting directories/files for FINs or FCOs.
  