Document fcos/A0147-1


FCO #: A0147-1

SYNOPSIS: Rare but recoverable "write faults" may occur when adding or
          upgrading 18.2GB 7200 RPM FC-AL drives into the Sun StorEdge A5000

DATE: FCO #: A0147-1                				Aug/12/99

KEYWORDS: Rare but recoverable "write faults" may occur when adding or
          upgrading 18.2GB 7200 RPM FC-AL drives into the Sun StorEdge A5000


---------------------------------------------------------------------
- Sun Proprietary/Confidential: Internal Use Only -
---------------------------------------------------------------------  
                        FIELD CHANGE ORDER
                  (For Authorized Distribution by SunService)

 
SYNOPSIS: Rare but recoverable "write faults" may occur when adding or
          upgrading 18.2GB 7200 RPM FC-AL drives into the Sun StorEdge A5000.

TOP FIN/FCO REPORT: Yes

PRODUCT_REFERENCE: A5000 drive guide

PRODUCT CATEGORY: Storage / A5000

PRODUCTS AFFECTED:

Systems Affected:

Mkt_ID           Platform   Model   Description           Serial Number
------           --------   -----   -----------           -------------
   -               A14        -     Ultra Enterprise 2          -
   -               E450       -     Ultra Enterprise 450        -
   -               E3000      -     Ultra Enterprise 3000       -
   -               E3500      -     Ultra Enterprise 3500       -
   -               E4000      -     Ultra Enterprise 4000       -
   -               E4500      -     Ultra Enterprise 4500       -
   -               E5000      -     Ultra Enterprise 5000       -
   -               E5500      -     Ultra Enterprise 5500       -
   -               E6000      -     Ultra Enterprise 6000       -
   -               E6500      -     Ultra Enterprise 6500       -
   -               E10000     -     Ultra Enterprise 10000      -
   
X-options Affected:

Mkt_ID           Platform   Model   Description           Serial Number
------           --------   -----   -----------           -------------
SG-XARY510A-45G    A5000      -     45GB Table Top, Sun StorEdge A5000
SG-XARY010A-45G    A5000      -     45GB Table Top, Sun StorEdge A5000
SG-XARY510A-127G   A5000      -     127GB Table Top, Sun StorEdge A5000
SG-XARY010A-127G   A5000      -     127GB Table Top, Sun StorEdge A5000

PART NUMBERS AFFECTED:

Part Number   Description   Model
-----------   -----------   -----
N/A

(SCSI Devices)
Type    Vendor    Model     SerialNumber(Min)    SerialNumber(Max)    Firmware
----    ------    -------   ------------------   ------------------   --------
N/A

REFERENCES:
   ECO: WO_14564, WO_14180
   BugId: 4177817
   LEAP: 1037

PROBLEM DESCRIPTION:     

Ongoing reliability testing in Sun's test labs have revealed that when
adding/upgrading 18.2GB 7200 RPM FC-AL drives into the Sun StorEdge A5000,
customers could experience recoverable "write faults".  This will only
happen a small percentage of the time and will not happen in every case.
This problem will not occur when running typical read/write operations, but
could occur when running random seeks for read/writes across the entire disk,
such as one might see in a Rotational Vibration (RV) test, performance
tests and/or when Random Write Intensive disk operations are performed.

To Sun customers, this may show up as a performance drop in through-put.  
No data is lost or corrupted.  Customers that do not run Performance Tests 
on their Arrays, or use applications that DO NOT simulate the highly 
intensive Random Write stress of the RV test, are highly unlikely to see 
these errors.  To the best of our knowledge, this failure mode has not
been seen or reported from customers using the 18GB drives in the older
A5000 enclosures. 
           
 This problem will ONLY AFFECT;

   * Sun StorEdge A5000 Arrays that are adding/upgrading 18GB 7200RPM drives 
   * Sun StorEdge A5000 Arrays that were manufactured before January 1, 1999.

 This Problem will NOT AFFECT;

   * Sun StorEdge A5100 Arrays (which contain 18GB, 7200RPM drives)
   * Sun StorEdge A5200 Arrays (which contain 9GB, 10000RPM drives)
   * Sun StorEdge A5000 Arrays Manufactured after January 1, 1999
    (Note: The above StorEdge Arrays all contain revised Drive Guides)

Typical error symptoms are;
 
	write fault error
	track following error
	seek error
	
An example of a related write fault;

  WARNING: /sbus@1f,0/QLGC,isp@0,10000/sd@3,0 (sd123):
 	Error for Command: write                   Error Level: Recovered
 	Requested Block: 75712                     Error Block: 75712
 	Vendor: SEAGATE                            Serial Number:     009236  
 	Sense Key: Soft Error
 	ASC: 0x3 (peripheral device write fault), ASCQ: 0x0, FRU: 0x10
 
Root cause is that the higher capacity disk drives are more sensitive to
rotational vibration (RV), and under certain applications can cause a high
number of write re-tries.  The fix, a new ribbed drive guide, was implemented
in Sun Manufacturing via ECO WO_14180 in late December 1998.  Therefore, all
A5000s shipped on or after that date will have the new ribbed drive guide
and are not affected.

A new ribbed drive guide kit part number (565-1600-01) was released via
ECO# WO_14564 on February 24, 1999 and is available as a FRU for Enterprise
Services.

IMPLEMENTATION:

         ---
  	|   |  	MANDATORY (Fully Pro-Active)
	 ---    

         ---
  	|   | 	CONTROLLED PRO-ACTIVE (per Sun Geo Plan) 
	 ---   
			
         ---
  	| X | 	UPON FAILURE
	 ---
	

REPLACEMENT TIME ESTIMATE:   30 minutes

SPECIAL CONSIDERATIONS:

The exposure is only to the original Sun StorEdge A5000 Arrays that contain
9GB, 7200RPM drives.  The Ribbed Drive Guide Kit "IS NOT" intended as
an 
upgrade for every A5000 in the field.

This problem will ONLY AFFECT;

* Sun StorEdge A5000 TableTop Arrays manufactured before January 1, 1999

This Problem will NOT AFFECT;

 * Sun StorEdge A5100 Arrays (which contain 18GB, 7200RPM drives)
 * Sun StorEdge A5200 Arrays (which contain 9GB, 10000RPM drives)
 * Sun StorEdge A5000 Arrays Manufactured after January 1, 1999
 * Customers that do not run Performance Tests on their Arrays, or use 
   applications that DO NOT simulate the highly intensive Random Write 
   stress of the RV tests

CORRECTIVE ACTION:
  
Upon failure install Drive Guide Kit, Sun p/n 565-1600-01, in affected
StorEdge Arrays that have encountered the Rotational Vibration errors
after an upgrade of 18.2GB 7200RPM FC-AL drives.

COMMENTS:

The removal/installation of the drive guides is covered in the A5000
Installation and Service Manual (802-7573-15), section 7.2.10.  This covers 
removal/installation of the lower guides.  The upper guides are removed in 
a similar manner with the following difference.  After gently lifting the 
locking tab with a screw driver, push the guides toward the center of 
the A5000 and the guides will then drop down to be removed.

An online version of this manual can be found on EDIST at;

  http://edist.Central.Sun.COM/smcc/doc/802/802-7573-15/ps/

Section 7.2.10 is in the service document titled  015.service.ps

To identify if an A5000 already has the improved drive guides with
"ribs",
remove a drive from any slot.  The improved drive guides have a narrow rib 
running from front to back (in each slot).  The older drive guide does not
have the rib.  Each Drive Guide Kit is designed to address one A5000.
New Drive Guides were added to all A5x00 arrays after January 1st, 1999.

BILLING TYPE:

 Warranty: Sun will provide parts at no charge under Warranty 
           Service. On-Site Labor Rates are based on how the
           system was initially installed.

 Contract: Sun will provide parts at no charge. On-Site Labor Rates
           are based on the type of service contract.

 Non Contract: Sun will provide parts at no charge. Installation by
               Sun is available based on the On-Site Labor Rates 
               defined in the Price List.

--------------------------------------------------------------------------
Implementation Footnote:
________________________

i)   In case of Mandatory FCOs, Enterprise Services will attempt to contact
      all known customers to recommend the part upgrade.

ii)  For controlled proactive swap FCOs, Enterprise Services mission critical
     support teams will initiate proactive swap efforts for their respective 
     accounts, as required.

iii) For Replace upon Failure FCOs, Enterprise Services partners will implement

     the necessary corrective actions as and when they are required.

--------------------------------------------------------------------------
 
All released FINs and FCOs can be accessed using your favorite network 
browser as follows:
 
SunWeb Access: 
______________
 
* Access the top level URL of http://sdpsweb.EBay/FIN_FCO/

* From there, select the appropriate link to query or browse the FIN and
  FCO Homepage collections.
 
SunSolve Online Access:
_______________________
 
* Access the SunSolve Online URL at http://sunsolve.Central/

* From there, select the appropriate link to browse the FIN or FCO index.

Supporting Documents:
____________________
 
Supporting documents for FIN/FCOs can be found on Edist.  Edist can be 
accessed internally at the following URL: http://edist.Central/.
  
* From there, follow the hyperlink path of "SunService Documentation"
and 
  click on "FIN & FCO attachments", then choose the appropriate
folder,  
  FIN or FCO.  This will display supporting directories/files for FINs or
  FCOs.
   
Internet Access:
_______________
 
* Access the top level URL of https://infoserver.Sun.COM


--------------------------------------------------------------------------
General:
________

Send questions or comments to finfco-manager@sdpsweb.EBay

---------------------------------------------------------------------------



Copyright (c) 1997-2003 Sun Microsystems, Inc.