Document fcos/A0156-1


FCO #: A0156-1

SYNOPSIS: StorEdge A5200 with -03 backplane may fail the LBF test in Stortools
          after adding or replacing 9GB or 18GB 10K RPM disk drives

DATE: Dec/17/99

KEYWORDS: StorEdge A5200 with -03 backplane may fail the LBF test in Stortools
          after adding or replacing 9GB or 18GB 10K RPM disk drives


---------------------------------------------------------------------
- Sun Proprietary/Confidential: Internal Use Only -
---------------------------------------------------------------------  
                               FIELD CHANGE ORDER
                  (For Authorized Distribution by SunService)

 
SYNOPSIS: StorEdge A5200 with -03 backplane may fail the LBF test in Stortools
          after adding or replacing 9GB or 18GB 10K RPM disk drives.

TOP FIN/FCO REPORT: Yes

PRODUCT_REFERENCE: A5000 Backplane

PRODUCT CATEGORY: Storage / A5000

PRODUCTS AFFECTED:

Systems Affected:

Mkt_ID    Platform   Model   Description           Serial Number
------    --------   -----   -----------           -------------
   -        A14        -     Ultra Enterprise 2          -
   -        E450       -     Ultra Enterprise 450        -
   -        E3000      -     Ultra Enterprise 3000       -
   -        E3500      -     Ultra Enterprise 3500       -
   -        E4000      -     Ultra Enterprise 4000       -
   -        E4500      -     Ultra Enterprise 4500       -
   -        E5000      -     Ultra Enterprise 5000       -
   -        E5500      -     Ultra Enterprise 5500       -
   -        E6000      -     Ultra Enterprise 6000       -
   -        E6500      -     Ultra Enterprise 6500       -
   -        E10000     -     Ultra Enterprise 10000      -
   
X-options Affected:

Mkt_ID    Platform   Model   Description                        Serial Number
------    --------   -----   -----------                        -------------
SG-ISV520A-63G     A5200  -  StorEdge A5200 7x9GB drv Min             -
SG-XARY520A-63G    A5200  -  StorEdge A5200 7x9GB drv Min             -
SG-ARY523A-400G    A5200  -  StorEdge A5200 Rack w/2 22x9GB drv Min   -
SG-XARY523A-400G   A5200  -  StorEdge A5200 Rack w/2 22x9GB drv Min   -

SG-ARY523A-800G    A5200  -  StorEdge A5200 Rack w/2 22x9GB drv Mid   -
SG-XARY523A-800G   A5200  -  StorEdge A5200 Rack w/2 22x9GB drv Mid   -

SG-ARY520A-200G    A5200  -  StorEdge A5200 22x9GB drv Max            -
SG-ARY521A-200GR5  A5200  -  StorEdge A5200 22x9GB drv Max            -
SG-ARY522A-200GR4  A5200  -  StorEdge A5200 22x9GB drv Max            -
SG-ARY523A-200G	   A5200  -  StorEdge A5200 22x9GB drv Max            -
SG-XARY520A-200G   A5200  -  StorEdge A5200 22x9GB drv Max            -
SG-XARY521A-200G   A5200  -  StorEdge A5200 22x9GB drv Max            -
SG-XARY522A-200G   A5200  -  StorEdge A5200 22x9GB drv Max            -

SG-ARY523A-1200G   A5200  -  StorEdge A5200 Rack w/4 22x9GB drv Max   -
SG-XARY523A-1200G  A5200   - StorEdge A5200 Rack w/4 22x9GB drv Max   -


PART NUMBERS AFFECTED:

Part Number   Description                     Model
-----------   -----------                     -------
501-4158-03   ASSY,HDA 11SLT BACKPLNE,PHOTON    -


(SCSI Devices)
Type    Vendor    Model     SerialNumber(Min)    SerialNumber(Max)    Firmware
----    ------    -------   ------------------   ------------------   --------
N/A

REFERENCES:
   ECO: WO_14866, WO_14814
   LEAP: 1013
   BugId: 4245760

kn1ght

PROBLEM DESCRIPTION:     

StorEdge A5200 with 11 slot HDA (501-4158-03) may fail LBF test in Stortools,
and experience various SCSI Errors that are captured in the syslog file
(/var/adm/messages).  Examples of errors that might be seen are;

  SCSI Parity, 
  CRC, 
  SCSI Transport, or 
  SCSI Transport Reject errors

During qualification of the next generation 9GB (540-3869-xx) Seagate and
18GB (540-4191-xx) Seagate drives in the StorEdge A5200, it was found that
the original HDA 11 Slot Backplane (501-4158-03) was failing the LBF test
in Stortools and showing CRC and SCSI parity errors.

All StorEdge A5200 systems shipped prior to March 28, 1999 could be affected
when xoption 6720A (18GB 10K FCAL Drive) or xoption 6710A (9GB 10K FCAL Drive)
are installed.

Corrective action was made available on March 18, 1999 via ECO# WO_14814 by
adding capacitors and dash rolling the 501-4158-03 to -04.  The 501-4158-04
was released into the A5200 chassis in Sun Manufacturing on March 28, 1999
via ECO# WO_14866.

IMPLEMENTATION:

         ---
  	|   |  	MANDATORY (Fully Pro-Active)
	 ---    

         ---
        | X |   CONTROLLED PRO-ACTIVE (per Sun Geo Plan) 
	 ---   
			
         ---
  	|   | 	UPON FAILURE
	 ---
	

REPLACEMENT TIME ESTIMATE:   45 minutes

SPECIAL CONSIDERATIONS:

Because the error showed in Stortools as LBF fail or Loop Integrity Soft Error,
and appeared to have a higher failure frequency than the current 9GB 10K drive,
Engineering decided to recommend that customers with MIN trays shipped prior to
March 28, 1999, and looking to add 11 or more xoptions of the new drives should

schedule a time to upgrade the 501-4158-03 backplane to 501-4158-04 prior to
installation of their xoptions.

Secondary exposure would be customers requiring drive FRUs for those A5200 22
drive max chassis shipped prior to March 28, 1999.  Because the failures are
believed to be related to the drives increased capacity and modified timing,
the failure frequency is tied to the number of new drives in the chassis.  In
other words, replacing one or two of the old drives with new drive FRUs will
not result in increased failures.  Updating the backplane to dash -04 at the
next scheduled maintenance appointment is sufficient to cover this low
exposure.

CORRECTIVE ACTION:
  
Upon failure or at next service call replace any 501-4158-03
(HDA 11 Slot Backplane) with 501-4158-04 or above.

Determine the dash level of the 11-slot backplane in the A5200 by using
`luxadm display [array name]', or by selecting the Backplane Icon on the FPM:
        
  Backplane revision 02 on FPM (or in luxadm output) = 501-4158-03 backplane
  Backplane revision 03 on FPM (or in luxadm output) = 501-4158-04 backplane
  
BILLING TYPE:

 Warranty: Sun will provide parts at no charge under Warranty 
           Service. On-Site Labor Rates are based on how the
           system was initially installed.

 Contract: Sun will provide parts at no charge. On-Site Labor Rates
           are based on the type of service contract.

 Non Contract: Sun will provide parts at no charge. Installation by
               Sun is available based on the On-Site Labor Rates 
               defined in the Price List.

--------------------------------------------------------------------------
Implementation Footnote:
________________________

i)   In case of Mandatory FCOs, Enterprise Services will attempt to contact
      all known customers to recommend the part upgrade.

ii)  For controlled proactive swap FCOs, Enterprise Services mission critical
     support teams will initiate proactive swap efforts for their respective 
     accounts, as required.

iii) For Replace upon Failure FCOs, Enterprise Services partners will implement

     the necessary corrective actions as and when they are required.

--------------------------------------------------------------------------
 
All released FINs and FCOs can be accessed using your favorite network 
browser as follows:
 
SunWeb Access: 
______________
 
* Access the top level URL of http://sdpsweb.EBay/FIN_FCO/

* From there, select the appropriate link to query or browse the FIN and
  FCO Homepage collections.
 
SunSolve Online Access:
_______________________
 
* Access the SunSolve Online URL at http://sunsolve.Central/

* From there, select the appropriate link to browse the FIN or FCO index.

Supporting Documents:
____________________
 
Supporting documents for FIN/FCOs can be found on Edist.  Edist can be 
accessed internally at the following URL: http://edist.Central/.
  
* From there, follow the hyperlink path of "SunService Documentation"
and 
  click on "FIN & FCO attachments", then choose the appropriate
folder,  
  FIN or FCO.  This will display supporting directories/files for FINs or
  FCOs.
   
Internet Access:
_______________
 
* Access the top level URL of https://infoserver.Sun.COM


--------------------------------------------------------------------------
General:
________

Send questions or comments to finfco-manager@Sun.COM

---------------------------------------------------------------------------


Copyright (c) 1997-2003 Sun Microsystems, Inc.