Document fcos/A0164-1


FCO #: A0164-1

SYNOPSIS: Systems with FC100/P cards (QL2100 PCI FC-AL HBA) having Molex
          optical transceivers, may cause increasing numbers of loop errors,
          excessive LIPs, and SCSI parity errors as they age

DATE: May/12/00

KEYWORDS: Systems with FC100/P cards (QL2100 PCI FC-AL HBA) having Molex
          optical transceivers, may cause increasing numbers of loop errors,
          excessive LIPs, and SCSI parity errors as they age


---------------------------------------------------------------------
- Sun Proprietary/Confidential: Internal Use Only -
---------------------------------------------------------------------  
                               FIELD CHANGE ORDER
                  (For Authorized Distribution by SunService)

 
SYNPOSIS: Systems with FC100/P cards (QL2100 PCI FC-AL HBA) having Molex
          optical transceivers, may cause increasing numbers of loop
          errors, excessive LIPs, and SCSI parity errors as they age.

TOP FIN/FCO REPORT: Yes

PRODUCT_REFERENCE: PCI FC-AL optical transceiver loop errors

PRODUCT CATEGORY: Storage / A5000 ; Server / Other ; Storage / A3500

PRODUCTS AFFECTED:

Mkt_ID   Platform   Model   Description   Serial Number
------   --------   -----   -----------   -------------

Systems Affected
------- ---------

  -       A20        ALL    Ultra 450            -
  -       A23        ALL    Ultra 60             -
  -       A25        ALL    Enterprise 450     	 -
  -       A26        ALL    Enterprise 250       -
  -       A27        ALL    Ultra 80             -
  -       A33        ALL    Enterprise 420R      -
  -       A34        ALL    Enterprise 220R      -

X-options Affected    
--------- --------
X6729A	   -          -     PCI FC-AL single-loop host adapter   -

  -      A5000        -     Enterprise Network StorEdge A5000 FC-AL  -
  -      A5100        -     Enterprise Network StorEdge A5100 FC-AL  -
  -      A5200        -     Enterprise Network StorEdge A5200 FC-AL  -
  -      A3500FC      -     Enterprise Network StorEdge A3500 FC-AL  -


PART NUMBERS AFFECTED:

Part Number              Description      Model
-----------              -----------      -------
375-0040-02 (or below)   FC-AL PCI Card     -

(SCSI Devices)
Type    Vendor    Model     SerialNumber(Min)    SerialNumber(Max)    Firmware
----    ------    -------   ------------------   ------------------   --------
N/A

REFERENCES:
   ECO: WO_16166
   LEAP: 1074A
   DPCO: 182
   BugId: 4302402, 4188166, 4298786
   Esc: 524139, 524001, 523908, 523904, 524144, 524610

PROBLEM DESCRIPTION:     

A host system using the 375-0040-01 or -02 FC-AL PCI card to attach to FC-AL
storage, may experience loop errors which affect data access to that storage.
In extreme cases, this can result in the host losing its connection to the
storage completely.  However, it is more common for the loop errors to be
intermittent initially, perhaps becoming more frequent over a period of days
or a few weeks.  The failures are sometimes sensitive to the data pattern on
the FC-AL loop, so they are not always reproducible with current diagnostic
software.

Below are examples of error messages;

 unix: ifp0:   Loop down
 unix: ifp0:   Loop is down: finishing off loop reconfig
 unix: ifp0:   Loop reconfigure done, LIP
 unix: WARNING: /pci@1f,2000/SUNW,ifp@1/ssd@w21000020370d323b,0 (ssd58):
 unix: requeue of command fails (fffffffe)

- or -

 unix: WARNING: /pci@1f,2000/SUNW,ifp@1/ssd@w21000020371430cd,0(ssd2):
 unix: Error for Command: write(10)  Error  Level: Retryable
 unix: Requested Block: 4241   Error  Block: 4241
 unix: Vendor: SEAGATE    Serial Number: 9833X17325  
 unix: Sense Key: Aborted Command
 unix: ASC: 0x47 (scsi parity error), ASCQ: 0x0, FRU: 0x3

Root Cause has determined that the Molex optical transceivers on FC100/P cards
(Sun p/n 375-0040-01 and -02) may experience premature failure.  To improve
overall product reliability Siemens optical transceiver modules are now used
on the 375-0040-03.

Corrective action was taken in Sun Manufacturing on  November 3, 1999 by
releasing the 375-0040-03 via ECO# WO_16166.

Corrective action was initially taken in Enterprise Services on December 20th,
1999 via LEAP_1074 which called for the rework upon failure of the 375-0040-02
FC100/P cards to -03 .  Follow up corrective action was taken in Enterprise
Services on March 20th, 2000 via LEAP_1074A and DPCO_182 which called for the
purge and rework of all 375-0040-01 and -02 FC100/P cards to -03. 

Identifying Affected FC-AL PCI Cards
------------------------------------

 Online method of identifying 375-0040-01 FC-AL PCI Cards;

   prtconf -pv
       ...
       compatible: 'pci1077,2100'
       manufacturer:  'QLGC'
       device_type:  'fcal'
       name:  'SUNW,ifp'
       ...
       revision-id:  00000003   [ISP2100 chip rev 3 and lower denote -01 card]
       device-id:  00002100 ^
       vendor-id:  00001077

   dmesg
   
       pci1077,21000 is /pci@1f,4000/SUNW,ifp@4
       ifp0:   Chip 2100 Rev 3; Firmware Version: 1.17.30
                             ^
       [ISP2100 chip rev 3 and lower denote -01 card]
       
   If rev 4 is reported card maybe either a -02 or -03.
       
 Visual methods of identifying revision level of FC-AL PCI Cards;

   Molex transceiver (defective) has BLACK tabs inside the black SC
   connector housing.  This transceiver may be found on either the
   -01 or -02 boards.
  
   Siemens transceiver (good) has WHITE tabs inside the black SC
   connector housing.  This transceiver started shipping on the
   -03 boards, and will be found on boards reworked to -03.

   The optical cable must be pulled out from the FC-AL PCI Card
   to order to check tab color.
  
IMPLEMENTATION:

         ---
  	|   |  	MANDATORY (Fully Pro-Active)
	 ---    

         ---
        | X |   CONTROLLED PRO-ACTIVE (per Sun Geo Plan) 
	 ---   
			
         ---
  	|   | 	UPON FAILURE
	 ---
	

REPLACEMENT TIME ESTIMATE:   30 mins

SPECIAL CONSIDERATIONS:

CORRECTIVE ACTION:
  
Upon failure or upon request replace 375-0040-02 (or below) with 375-0040-03.


BILLING TYPE:

 Warranty: Sun will provide parts at no charge under Warranty 
           Service. On-Site Labor Rates are based on how the
           system was initially installed.

 Contract: Sun will provide parts at no charge. On-Site Labor Rates
           are based on the type of service contract.

 Non Contract: Sun will provide parts at no charge. Installation by
               Sun is available based on the On-Site Labor Rates 
               defined in the Price List.

--------------------------------------------------------------------------
Implementation Footnote:
________________________

i)   In case of Mandatory FCOs, Enterprise Services will attempt to contact
      all known customers to recommend the part upgrade.

ii)  For controlled proactive swap FCOs, Enterprise Services mission critical
     support teams will initiate proactive swap efforts for their respective 
     accounts, as required.

iii) For Replace upon Failure FCOs, Enterprise Services partners will implement

     the necessary corrective actions as and when they are required.

--------------------------------------------------------------------------
 
All released FINs and FCOs can be accessed using your favorite network 
browser as follows:
 
SunWeb Access: 
______________
 
* Access the top level URL of http://sdpsweb.EBay/FIN_FCO/

* From there, select the appropriate link to query or browse the FIN and
  FCO Homepage collections.
 
SunSolve Online Access:
_______________________
 
* Access the SunSolve Online URL at http://sunsolve.Central/

* From there, select the appropriate link to browse the FIN or FCO index.

Supporting Documents:
____________________
 
Supporting documents for FIN/FCOs can be found on Edist.  Edist can be 
accessed internally at the following URL: http://edist.Central/.
  
* From there, follow the hyperlink path of "SunService Documentation"
and 
  click on "FIN & FCO attachments", then choose the appropriate
folder,  
  FIN or FCO.  This will display supporting directories/files for FINs or
  FCOs.
   
Internet Access:
_______________
 
* Access the top level URL of https://infoserver.Sun.COM


--------------------------------------------------------------------------
General:
________

Send questions or comments to finfco-manager@Sun.COM

---------------------------------------------------------------------------


Copyright (c) 1997-2003 Sun Microsystems, Inc.