Document fcos/A0167-1
FCO #: A0167-1
SYNOPSIS: VRM Interposer board (375-0094-01) can cause intermittent system
resets in the Enterprise 220R
DATE: Sep/12/00
KEYWORDS: VRM Interposer board (375-0094-01) can cause intermittent system
resets in the Enterprise 220R
---------------------------------------------------------------------
- Sun Proprietary/Confidential: Internal Use Only -
---------------------------------------------------------------------
FIELD CHANGE ORDER
(For Authorized Distribution by SunService)
SYNOPSIS: VRM Interposer board (375-0094-01) can cause intermittent system
resets in the Enterprise 220R.
TOP FIN/FCO REPORT: Yes
PRODUCT_REFERENCE: E220R / VRM Interposer Card
PRODUCT CATEGORY: Server / Power
PRODUCTS AFFECTED:
Mkt_ID Platform Model Description Serial Number
------ -------- ----- ----------- -------------
Systems Affected
------- --------
A34-AA E220R - Enterprise 220R -
X-options Affected
--------- --------
PART NUMBERS AFFECTED:
Part Number Description Model
----------- ----------- -----
375-0094-01 VRM Interposer (without deviation WO_17041) -
(SCSI Devices)
Type Vendor Model SerialNumber(Min) SerialNumber(Max) Firmware
---- ------ ------- ------------------ ------------------ --------
N/A
REFERENCES:
ECO: WO_17257
LEAP: 1097
WW StopShip: WS001#03634
Deviation: WO_17041
PROBLEM DESCRIPTION:
The VRM Interposer board (Sun p/n 375-0094-01) can cause intermittent system
resets in the Enterprise 220R (Razor) under high-load conditions. A high-load
condition is defined as anytime the CPU modules are drawing higher than normal
power. This is primarily dependent on the system configuration (two processors
versus one) as well as what software is running at the time. No system errors
are reported.
Root Cause has determined the circuit that generates core power for the CPU
modules has an insufficient voltage margin, and under high-load conditions
may prematurely signal an overvoltage condition which causes the system to
reset. The fix modifies the VRM Interposer board (375-0094-01) to better
use the margin that the VRM overvoltage detector provides thereby avoiding
a premature overvoltage condition.
Corrective action was implemented in Manufacturing on February 19th, 2000
via Deviation ECO# WO_17041.
Corrective action was made available to Enterprise Services on May 8th, 2000
by the availability of the 375-0094-02 via ECO# WO_17257.
IMPLEMENTATION:
---
| | MANDATORY (Fully Pro-Active)
---
---
| X | CONTROLLED PRO-ACTIVE (per Sun Geo Plan)
---
---
| | UPON FAILURE
---
REPLACEMENT TIME ESTIMATE: 0.5 hours
SPECIAL CONSIDERATIONS:
Enterprise 220R systems started shipping with fixed VRM Interposer Boards
(375-0094-01 w/Deviation label DEV# WO_17041) as of February 19, 2000.
Enterprise 220R systems started shipping with fixed VRM Interposer Boards
(375-0094-02) as of May 8th, 2000.
CORRECTIVE ACTION:
Upon failure or request replace 375-0094-01 with 375-0094-02 or 375-0094-01
with Deviation Label "DEV# WO_17041".
BILLING TYPE:
Warranty: Sun will provide parts at no charge under Warranty
Service. On-Site Labor Rates are based on how the
system was initially installed.
Contract: Sun will provide parts at no charge. On-Site Labor Rates
are based on the type of service contract.
Non Contract: Sun will provide parts at no charge. Installation by
Sun is available based on the On-Site Labor Rates
defined in the Price List.
--------------------------------------------------------------------------
Implementation Footnote:
________________________
i) In case of Mandatory FCOs, Enterprise Services will attempt to contact
all known customers to recommend the part upgrade.
ii) For controlled proactive swap FCOs, Enterprise Services mission critical
support teams will initiate proactive swap efforts for their respective
accounts, as required.
iii) For Replace upon Failure FCOs, Enterprise Services partners will implement
the necessary corrective actions as and when they are required.
--------------------------------------------------------------------------
All released FINs and FCOs can be accessed using your favorite network
browser as follows:
SunWeb Access:
______________
* Access the top level URL of http://sdpsweb.EBay/FIN_FCO/
* From there, select the appropriate link to query or browse the FIN and
FCO Homepage collections.
SunSolve Online Access:
_______________________
* Access the SunSolve Online URL at http://sunsolve.Central/
* From there, select the appropriate link to browse the FIN or FCO index.
Supporting Documents:
____________________
Supporting documents for FIN/FCOs can be found on Edist. Edist can be
accessed internally at the following URL: http://edist.Central/.
* From there, follow the hyperlink path of "SunService Documentation"
and
click on "FIN & FCO attachments", then choose the appropriate
folder,
FIN or FCO. This will display supporting directories/files for FINs or
FCOs.
Internet Access:
_______________
* Access the top level URL of https://infoserver.Sun.COM
--------------------------------------------------------------------------
General:
________
Send questions or comments to finfco-manager@Sun.COM
---------------------------------------------------------------------------
Copyright (c) 1997-2003 Sun Microsystems, Inc.