Document fcos/A0202-1
FCO #: A0202-1
SYNOPSIS: Mirrored 20GB disk drives on Ultra 10 and Sun Blade 100 systems may
be exposed to a drive compatibility issue when replacing a failed
drive)
DATE: Sep/27/2002
KEYWORDS: Mirrored 20GB disk drives on Ultra 10 and Sun Blade 100 systems may
be exposed to a drive compatibility issue when replacing a failed
drive)
---------------------------------------------------------------------
- Sun Proprietary/Confidential: Internal Use Only -
---------------------------------------------------------------------
FIELD CHANGE ORDER
(For Authorized Distribution by SunService)
SYNOPSIS: Mirrored 20GB disk drives on Ultra 10 and Sun Blade 100
systems may be exposed to a drive compatibility issue
when replacing a failed drive.
Sun Alert: No
TOP FIN/FCO REPORT: No
PRODUCT_REFERENCE: Workstation Harddisk
PRODUCT CATEGORY: DeskTop / System Component
PRODUCT AFFECTED:
Systems Affected:
Mkt_ID Platform Model Description Serial Number
------ -------- ----- ----------- -------------
- A22 - Ultra 10 -
- A36 - Sun Blade 100 -
X-Options Affected:
Mkt_ID Platform Model Description Serial Number
------ -------- ----- ----------- -------------
- - - - -
AFFECTED PARTS:
Part Number Description Model
----------- ----------- -----
370-4327-01 ATA Disk Drive 20.0GB ST320414A
ATA Disk Drive 20.0GB ST320011A
ATA Disk Drive 20.4GB ST320420A
REFERENCES
LEAP: 2051
BugID: 4673592
ESC: 536839
Radiance: 10169433
ECO: WO_24317
PROBLEM DESCRIPTION :
Seagate 20.0GB and 20.4GB disk drives, used on Ultra 10 and Sun Blade 100
systems, are both identified with the same SUN part number (370-4327).
A problem can arise when a replacement of one of the mirrored disk drives
is required.
If a mirrored 20GB disk drive fails on one of these platforms it is
important to ensure that the same capacity drive is used so that
the replacement drive is compatable with it's mirrored counter-part.
In some cases it may be necessary to replace both 20GB disk drives
to ensure they both are of the same capacity.
The root cause of this problem is that there are two drives with two
similar but different capacities reporting to the same part number
(F370-4327). The failing condition exist when disk mirroring is used
and the drive capacities are not similar.
The corrective action was made available via ECO WO_24317 on
August 7, 2002 releasing part number 370-5560-01, which is a 20.4GB
(only) disk drive.
When replacing a failed 20GB mirrored disk drive on a Ultra 10 or
Sun Blade 100 system please follow the instructions listed in the
Corrective Action section below.
PLANNED IMPLEMENTATION COMPLETION DATE: September 30, 2004
IMPLEMENTATION :
---
| | MANDATORY (Fully Pro-Active)
---
---
| | CONTROLLED PRO-ACTIVE (per Sun Geo Plan)
---
---
| X | UPON FAILURE
---
REPLACEMENT TIME ESTIMATE : .5 hours
SPECIAL CONSIDERATION :
CORRECTIVE ACTION :
For those customers who have experienced a failure on a mirrored
Seagate 20.0GB or 20.4GB disk drive, follow the below guidelines;
1. If the system has mirrored 20.4GB disk drives, replace the faulty
drive with part number 370-5560.
2. If the system has mirrored 20.0GB disk drives, replace both drives
with part number 370-5560, thus ensuring matching capacities.
If the service is being done for a customer NOT covered under a
product warranty or service contract, the second drive should be
provided at no cost to the customer.
COMMENTS :
For those customers who do NOT mirror their disk drives and
experience a 20GB disk failure, please continue to use Sun
part number 370-4327 as the replacement.
http://plc-ims-2.central:9090/servlet/fcopm.fco.FCO_Gliap?A0202-1
BILLING TYPE:
Warranty: Sun will provide parts at no charge under Warranty
Service. On-Site Labor Rates are based on how the
system was initially installed.
Contract: Sun will provide parts at no charge. On-Site Labor Rates
are based on the type of service contract.
Non Contract: Sun will provide parts at no charge. Installation by
Sun is available based on the On-Site Labor Rates
defined in the Price List.
--------------------------------------------------------------------------
Implementation Footnote:
________________________
i) In case of Mandatory FCOs, Sun Services will attempt to contact
all known customers to recommend the part upgrade.
ii) For controlled proactive swap FCOs, Sun Services mission critical
support teams will initiate proactive swap efforts for their respective
accounts, as required.
iii) For Replace upon Failure FCOs, Sun Services partners will implement
the necessary corrective actions as and when they are required.
--------------------------------------------------------------------------
All released FINs and FCOs can be accessed using your favorite network
browser as follows:
SunWeb Access:
______________
* Access the top level URL of http://sdpsweb.EBay/FIN_FCO/
* From there, select the appropriate link to query or browse the FIN and
FCO Homepage collections.
SunSolve Online Access:
_______________________
* Access the SunSolve Online URL at http://sunsolve.Central/
* From there, select the appropriate link to browse the FIN or FCO index.
Internet Access:
_______________
* Access the top level URL of https://infoserver.Sun.COM
--------------------------------------------------------------------------
General:
________
Send questions or comments to finfco-manager@Sun.COM
---------------------------------------------------------------------------