Document fins/I0358-1


FIN #: I0358-1

SYNOPSIS: Possibility of stripping the mounting screws of the E450 Power Supply
          due to mechanical interference on the chasis.

DATE: Nov/04/97

KEYWORDS: Possibility of stripping the mounting screws of the E450 Power Supply
          due to mechanical interference on the chasis.


---------------------------------------------------------------------
        - Sun Proprietary/Confidential: Internal Use Only -
---------------------------------------------------------------------  
                        FIELD INFORMATION NOTICE
                  (For Authorized Distribution by SunService)


SYNOPSIS: Possibility of stripping the mounting screws of the E450 Power
	  Supply due to mechanical interference on the chasis.

PRODUCT CATEGORY: System	

PRODUCTS AFFECTED: 

	A25-UXX1-9S-XXXCD	Enterprise 450 Server series
	X9682A			X-Option, 560W Power Supply for Enterprise 450


PART NUMBERS AFFECTED: 

	300-1302-02		560W Power Supply
	F300-1302-02		FRU, 560W Power Supply
	300-1359-01		560W Power Supply
	F300-1359-01		FRU, 560W Power Supply
	

REFERENCES: 

	805-0430-10 Ultra450 Workstation Owner's Guide	
	805-0429-10 E450 Server Owner's Guide	

	
PROBLEM DESCRIPTION:

There is a small exposure with the E450 power supply X-option and
FRU's. This is due to a mechanical interference between the E450
system chassis and the inner side of the power supply ejectors.

Manufacturing has been seeing 1 or 2 rejects per week for stripped
screws and this is the root cause.

The X-options and FRUs that are out in the field may exhibit this
problem and the installer could conceivably strip a screw.


CORRECTIVE ACTION: 

When removing/replacing a power-supply, DO NOT use excessive force to
tighten the mounting screws. Check for binding of the mounting screws
during tightening, If binding occurs back-out and re-tighten the screw
to alleviate the binding of the screw.

	
COMMENTS:  

The E450 chassis manufacturer will correct this interference issue in
the coming months.

--------------------------------------------------------------------------
SunWeb Access: 
______________

All released FINs and FCOs can be accessed internally on the SunWeb using
your favorite network browser as follows:
 
* Access the top level URL of http://cte.corp/FIN_FCO/
 
* From there, select the appropriate link to query or browse the FIN and
  FCO Homepage collections.
 
Supporting documents for FINs/FCOs can be found on the Edist Website. The
Edist Website can be accessed internally at the following URL:
			
			 http://edist.corp/
 
* From there, follow the hyperlink path of "SunService Documentation"
and 
  choose the appropriate folder, FIN or FCO.  This will display supporting   
  directories/files for FINs or FCOs.

--------------------------------------------------------------------------
General:
________

Send questions or comments to finfco-manager@cte.Corp

---------------------------------------------------------------------------


Copyright (c) 1997-2003 Sun Microsystems, Inc.