Document fins/I0385-1


FIN #: I0385-1

SYNOPSIS: Ultra 5 and 10 disk drive options could encounter problems with
          invalid labels

DATE: Mar/31/98		

KEYWORDS: Ultra 5 and 10 disk drive options could encounter problems with
          invalid labels


---------------------------------------------------------------------
        - Sun Proprietary/Confidential: Internal Use Only -
---------------------------------------------------------------------  
                        FIELD INFORMATION NOTICE
                  (For Authorized Distribution by SunService)




SYNOPSIS:   Ultra 5 and 10 disk drive options could encounter problems
            with invalid labels.


TOP FIN/FCO REPORT: Yes 


PRODUCT_REFERENCE:  Disk label 


PRODUCT CATEGORY:   Desktop / Ultra 5 / Ultra 10


PRODUCTS AFFECTED:

Mkt_ID                    		Description             
------                    		-----------

A21-UFE1Z9S-64AG   	Sun Enterprise Ultra 5S    
A21-UFE1Z9S-128CG   	Sun Enterprise Ultra 5S    
A21-UFE1Z9S-256CG	Sun Enterprise Ultra 5S    
A21-UFE1A9J-64AG	Sun Enterprise Ultra 5             
A21-UFE1A9J-128AG	Sun Enterprise Ultra 5             
A21-UFE1A9J-128CG	Sun Enterprise Ultra 5             
A21-UFE1A9J-256CG	Sun Enterprise Ultra 5             


A22-UEA1Z9S-64AG	Sun Enterprise Ultra 10S   
A22-UEA1Z9S-128CG	Sun Enterprise Ultra 10S
A22-UEA1Z9S-256CG 	Sun Enterprise Ultra 10S   
A22-UEA1Z9S-512CG	Sun Enterprise Ultra 10S   
A22-UEA1A9J-64AG	Sun Enterprise Ultra 10                   
A22-UEA1A9J-128CG	Sun Enterprise Ultra 10                   
A22-UEA1A9J-256CG	Sun Enterprise Ultra 10                   
A22-UEA1A9J-512CG	Sun Enterprise Ultra 10                   
A22-UEA1A9K-64AG	Sun Enterprise Ultra 10                   
A22-UEA1A9K-128C	Sun Enterprise Ultra 10                   
A22-UEA1A9K-256CG	Sun Enterprise Ultra 10                   
A22-UEA1A9K-512CG	Sun Enterprise Ultra 10                   
A22-UEA1A9L-64AG	Sun Enterprise Ultra 10                   
A22-UEA1A9L-128CG	Sun Enterprise Ultra 10                   
A22-UEA1A9L-256CG	Sun Enterprise Ultra 10                   
A22-UEA1A9L-512CG	Sun Enterprise Ultra 10                   
A22-UEA1A9Q-128CG	Sun Enterprise Ultra 10                   
A22-UEA1A9Q-256CG	Sun Enterprise Ultra 10                   
A22-UEA1A9Q-512CG	Sun Enterprise Ultra 10 
     
X5227A                                  FRU, DISK DRIVE 4.3GB EIDE
	

PART NUMBERS AFFECTED:

Part Number   Description
-----------   -----------
F370-3176-01	FRU, DISK DRIVE 4.3GB EIDE


REFERENCES:
N/A


PROBLEM DESCRIPTION:

Customers and Field Service Representatives that install X-option add-on
IDE disk drives or who are replacing an existing Ultra 5 or Ultra 10 disk
drive FRU, will encounter the following error when attempting to use the
format utility from the systems console:
	
# format

Searching for disks...WARNING: /pci@1f,0/pci@1,1/ide@3/dad@1,0 (dad1):         
        corrupt label - wrong magic number

WARNING: /pci@1f,0/pci@1,1/ide@3/dad@1,0 (dad1):
        corrupt label - wrong magic number
        

NOTE* Example screen output only. The number of messages will vary depend-
      ing upon how many devices without labels have been installed.
	 
	
Upon further investigation, it has become evident that NEW x-option and 
FRU IDE disk drives are un-labeled.  

        
CORRECTIVE ACTION:

Customers and Field Service Representatives that encounter the problem
of "corrupt label - wrong magic number" after installing add-on X-opton
IDE disk drives OR who replaces an existing IDE disk drive FRU, are 
prompted to perform the following workaround:

1.  After an IDE disk drive FRU or x-option IDE add-on drive has been
    installed in the system (Ultra 5 or Ultra 10), follow the routine
    service procedure to boot the system.

2.  Invoke the "format utility" and observe the following:

    *Example screen output for ONE IDE disk drive added to the system.
     
    # format

     Searching for disks...WARNING: /pci@1f,0/pci@1,1/ide@X/dad@X,0 (dadX):
     corrupt label - wrong magic number

     WARNING: /pci@1f,0/pci@1,1/ide@3/dad@X,0 (dadX):
     corrupt label - wrong magic number
        

    AVAILABLE DISK SELECTIONS:

       0. c0t1d0 <ST34342A cyl 8892 alt 2 hd 15 sec 63>
          /pci@1f,0/pci@1,1/ide@X/dad@X,X

      *1. c0t1d0 <ST34342A cyl 8892 alt 2 hd 15 sec 63>
          /pci@1f,0/pci@1,1/ide@3/dad@X,0

    Specify disk (enter its number): 1

	 
3.  Then select the disk number appropriately, *in this case disk 1 is the
    newly connected disk.
	

    Selecting c0t1d0
    No defect list found
    [disk formatted, no defect list found]


FORMAT MENU:
        disk       - select a disk
        type       - select (define) a disk type
        partition  - select (define) a partition table
        current    - describe the current disk
        format     - format and analyze the disk
        repair     - repair a defective sector
        show       - translate a disk address
        label      - write label to the disk
        analyze    - surface analysis
        defect     - defect list management
        backup     - search for backup labels
        verify     - read and display labels
        save       - save new disk/partition definitions
        volname    - set 8-character volume name
        !<cmd>     - execute <cmd>, then return
        quit
format> label



4.  Select the option "label" to label the selected drive.

    Ready to label disk, continue? y

5.  Confirm "y" for the above question.

    *After "y" is specified a NEW label will be written to the drive.

6.  At the "format" prompt enter quit.

    format> quit

7.  Now that the IDE disk drive has been labeled follow routine service
    procedures to partition the disk drive.

		
*The next time that the "format utility" is invoked, the "corrupt
label-
 wrong magic number" should not be evident if the IDE disk drive has been
 labeled correctly.

 
COMMENTS:

Beginning May 1, 1998, all Ultra 5 and Ultra 10 hard drive x-options
will arrive from the factory pre-formatted, pre-partitioned, and pre-
labeled, and it will no longer be necessary to follow the above
instructions for partitioning, and labeling.
   
--------------------------------------------------------------------------
SunWeb Access: 
______________

All released FINs and FCOs can be accessed internally on the SunWeb using
your favorite network browser as follows:

* Access the top level URL of http://cte.corp/FIN_FCO/

* From there, select the appropriate link to query or browse the FIN and
  FCO Homepage collections.

Supporting documents for FIN/FCOs can be found on Edist.  Edist can be 
accessed internally at the following URL: http://edist.corp/.
 
* From there, follow the hyperlink path of "SunService Documentation"
and 
  click on "FIN & FCO attachments", then choose the appropriate
folder, FIN
  or FCO.  This will display supporting directories/files for FINs or FCOs.

--------------------------------------------------------------------------
General:
________

Send questions or comments to finfco-manager@cte.Corp