Document fins/I0418-1


FIN #: I0418-1

SYNOPSIS: Sun Enterprise Volume Manager vxinstall script fails to detect an
          A5000 and create license.

DATE: Sep/09/98

KEYWORDS: Sun Enterprise Volume Manager vxinstall script fails to detect an
          A5000 and create license.


---------------------------------------------------------------------
        - Sun Proprietary/Confidential: Internal Use Only -
---------------------------------------------------------------------  
                        FIELD INFORMATION NOTICE
                  (For Authorized Distribution by SunService)



SYNOPSIS:    Sun Enterprise Volume Manager vxinstall script fails to  
             detect an A5000 and create license.


TOP FIN/FCO REPORT:  No


PRODUCT_REFERENCE:   Volume Manager vxinstall script


PRODUCT CATEGORY:    Storage / Software / Unbundled 

  
PRODUCTS AFFECTED:

       
          System
Mkt_ID    Platform   Model    Description           Serial Number
------    --------   -----    -----------           -------------

Systems Affected
------- ---------

  -       A14          -       Ultra Enterprise 2        -
  -       E450         -       Ultra Enterprise 450      -
  -       E3000        -       Ultra Enterprise 3000     -
  -       E3500        -       Ultra Enterprise 3500     -
  -       E4000        -       Ultra Enterprise 4000     -
  -       E4500        -       Ultra Enterprise 4500     -
  -       E5000        -       Ultra Enterprise 5000     -
  -       E5500        -       Ultra Enterprise 5500     -
  -       E6000        -       Ultra Enterprise 6000     -
  -       E6500        -       Ultra Enterprise 6500     -
  -       E10000       -       Ultra Enterprise 10000    -            
 
X-Options Affected
------------------
SG-XARY010A-45G   -   -       45.5GB Sun Enterprise Network Array  -
SG-XARY010A-127G  -   -      127.4GB Sun Enterprise Network Array  -
SG-XARY010A-254G  -   -      254.8GB Sun Enterprise Network Array  -
SG-XARY010A-509G  -   -      509.6GB Sun Enterprise Network Array  -
SG-XARY011A-127G  -   -      127.4GB Sun Enterprise Network Array  -    
SG-XARY012A-254G  -   -      254.8GB Sun Enterprise Network Array  -    
SG-XARY012A-509G  -   -      509.6GB Sun Enterprise Network Array  -    
SG-XARY512A-127G  -   -      127.4GB Sun Enterprise Network Array  -           

SG-XARY513A-254G  -   -      254.8GB Sun Enterprise Network Array  -    



PART NUMBERS AFFECTED:

Part Number    Description                                            Model
-----------    -----------                                            -----

EVM-2.5-B      Sun Enterprise Vol. Manager 2.5 Base Pack                 -    
EVM-2.5-DS-L   Sun Enterprise Vol. Manager 2.5 for Departmental Servers  -
EVM-2.5-ES-L   Sun Enterprise Vol. Manager 2.5 for Enterprise Servers    -
EVM-2.5-E10-L  Sun Enterprise Vol. Manager 2.5 for E10000 Servers        -
EVM-2.5-WG-L   Sun Enterprise Vol. Manager 2.5 for Workgroup Servers     -

EVM-2.6-B      Sun Enterprise Vol. Manager 2.6 Base Pack                 -
EVM-2.6-DS-L   Sun Enterprise Vol. Manager 2.6 for Departmental Servers  -
EVM-2.6-ES-L   Sun Enterprise Vol. Manager 2.6 for Enterprise Servers    -
EVM-2.6-E10-L  Sun Enterprise Vol. Manager 2.6 for E10000 Servers        -
EVM-2.6-WG-L   Sun Enterprise Vol. Manager 2.6 for Workgroup Servers     -


REFERENCES:

BugId: 4149377


PROBLEM DESCRIPTION:

The Sun Enterprise Volume Manager (SEVM) vxinstall script may fail   
to detect a StorEdge A5000(s) attached to a system and prompts for 
a license number to be entered.  This should not be the case since  
an automatic license should be generated for StorEdge A5000(s).
   
This problem is not reproducible at will although, it has been  
experienced at several customer sites and in engineering test labs.


CORRECTIVE ACTION:


In order to avoid the above stated problem with the SEVM vxinstall 
script and StorEdge A5000 detection, the following workaround has
been provided: 


 
1.  Run the following commands BEFORE running vxinstall.

    # vxconfigd -d
    # vxdctl license init



COMMENTS:



--------------------------------------------------------------------------
SunWeb Access: 
______________

All released FINs and FCOs can be accessed internally on the SunWeb using
your favorite network browser as follows:

* Access the top level URL of http://cte.corp/FIN_FCO/

* From there, select the appropriate link to query or browse the FIN and
  FCO Homepage collections.

Supporting documents for FIN/FCOs can be found on Edist.  Edist can be 
accessed internally at the following URL: http://edist.corp/.
 
* From there, follow the hyperlink path of "SunService Documentation"
and 
  click on "FIN & FCO attachments", then choose the appropriate
folder, FIN
  or FCO.  This will display supporting directories/files for FINs or FCOs.

--------------------------------------------------------------------------
General:
________

Send questions or comments to finfco-manager@cte.Corp

---------------------------------------------------------------------------



Copyright (c) 1997-2003 Sun Microsystems, Inc.