Document fins/I0447-1


FIN #: I0447-1

SYNOPSIS: SEVM2.5 patch 105463 may cause storage devices to disappear from
          system.

DATE: Nov/12/98 

KEYWORDS: SEVM2.5 patch 105463 may cause storage devices to disappear from
          system.


---------------------------------------------------------------------
        - Sun Proprietary/Confidential: Internal Use Only -
---------------------------------------------------------------------  
                        FIELD INFORMATION NOTICE
                  (For Authorized Distribution by SunService)



SYNOPSIS:   SEVM2.5 patch 105463 may cause storage devices to 
	    disappear from system.


TOP FIN/FCO REPORT:  Yes 
 
PRODUCT_REFERENCE:   vxdmp driver
                                                                               
  
PRODUCT CATEGORY:    Storage / Software / Unbundled   

PRODUCTS AFFECTED:  
 
Systems Affected
----------------
                 System
Mkt_ID           Platform   Model     Description       Serial Number
------           --------   -----     -----------       -------------

  -              A14          -       Ultra Enterprise 2        -
  -              E450         -       Ultra Enterprise 450      -
  -              E3000        -       Ultra Enterprise 3000     -
  -              E3500        -       Ultra Enterprise 3500     -
  -              E4000        -       Ultra Enterprise 4000     -
  -              E4500        -       Ultra Enterprise 4500     -
  -              E5000        -       Ultra Enterprise 5000     -
  -              E5500        -       Ultra Enterprise 5500     -
  -              E6000        -       Ultra Enterprise 6000     -
  -              E6500        -       Ultra Enterprise 6500     -
  -              E10000               Ultra Enterprise 10000    -

X-Options Affected
------------------

EVM-2.5-B    -            -     ENTERPRISE VOLUME MGR. 2.5, CD DOC  -
  -     SPARCstorage RSM  All   SPARCstorage Array RSM    -
  -          SSA          All   SPARCstorage Array        -
  -          RSM 2000     All   RSM Array 2000            -
  -          A3000        All   StorEdge A3000            -
  -          A5000        All   StorEdge A5000            -
  -          A1000        All   StorEdge A1000            -
  -          D1000        All   StorEdge D1000            -   


PART NUMBERS AFFECTED: 

Part Number   Description   Model
-----------   -----------   -----
    -              -          -

REFERENCES: 

BugId: 4158166
PatchId: 105463 
ESC: 515798, 516731 
	
PROBLEM DESCRIPTION:
  
When patch 105463 (SEVM2.5 patch) is applied on an operational system, 
and the system is rebooted, some storage devices may appear to be missing
or longer listed.

This symptom may also be experienced when installing EVM2.6, upon execution 
of vxinstall, not all of the storage devices on the system will be available 
for EVM to use.

This may happen on systems that have a mixture of storage devices, although
there have been reports of systems with a single SPARCstorage Array attached,
experiencing loss of access to some of the disks after application of this 
patch.  

The device loss is due to a modification that had been made to the DMP driver 
binary file in this release of the patch.

Systems that have disabled DMP operation will not experience this problem.


IMPLEMENTATION:
 
         ---
    	|   |  	MANDATORY (Fully Pro-Active)
  	 ---    
  	 
  
         ---
    	| X | 	CONTROLLED PRO-ACTIVE (per Sun Geo Plan) 
  	 --- 
  	 
  	   			
         ---
    	|   | 	REACTIVE (As Required)
  	 ---


	
CORRECTIVE ACTION:   
  
There are two recommended methods to resolve the problem with missing 
storage devices after the SEVM patch (105463-05) has been applied.
     
  1.  Backout the 105463 patch.
  
  2.  Disable DMP operations.  
  
PROACTIVE approach for those sites wishing to apply this patch, use 
of the following procedure will allow full functionality without the
system exhibiting device loss.
  
  1) Copy the /kernel/drv/vxdmp binary to another location on the system
  	# cp /kernel/drv/vxdmp /var/tmp/vxdmp
  
  2) Apply patch 105463.
  	# installpatch....
  	
  3) Move the binary copy back into place in the kernel/drv directory
  	# mv /var/tmp/vxdmp /kernel/drv/vxdmp
  	
  4) Shut down the system and reboot.

       
COMMENTS: 

  Veritas has provided a binary fix which will become patch 105463.
  This patch is scheduled for release in December 1998. 

--------------------------------------------------------------------------

Implementation Footnote:
________________________

i)   In case of MANDATORY FINs, Enterprise Services will attempt to contact   
     all affected customers to recommend implementation of the FIN. 
        

ii)  For CONTROLLED PROACTIVE FINs, Enterprise Services mission critical sup-  

     port teams will recommend implementation of the FIN (to their respective 
     accounts), at the convenience of the customer. 


iii) For REACTIVE FINs, Enterprise Services will implement the FIN as the need 

     arises.

-----------------------------------------------------------------------
 
All released FINs and FCOs can be accessed using your favorite network 
browser as follows:
 
SunWeb Access: 
______________
 
* Access the top level URL of http://cte.corp/FIN_FCO/

* From there, select the appropriate link to query or browse the FIN and
  FCO Homepage collections.
 
SunSolve Online Access:
_______________________
 
* Access the SunSolve Online URL at http://sunsolve.Corp/

* From there, select the appropriate link to browse the FIN or FCO index.

Supporting Documents:
____________________
 
Supporting documents for FIN/FCOs can be found on Edist.  Edist can be 
accessed internally at the following URL: http://edist.corp/.
  
* From there, follow the hyperlink path of "SunService Documentation"
and 
  click on "FIN & FCO attachments", then choose the appropriate
folder,  
  FIN or FCO.  This will display supporting directories/files for FINs or
  FCOs.
   
Internet Access:
_______________
 
* Access the top level URL of https://infoserver.Sun.COM
 
--------------------------------------------------------------------------
    
General:
________

Send questions or comments to finfco-manager@cte.Corp

---------------------------------------------------------------------------




Copyright (c) 1997-2003 Sun Microsystems, Inc.