Document fins/I0476-1


FIN #: I0476-1

SYNOPSIS:  Seating problems may be encountered when adding Ultra Enterprise 450
           internal disk drives.

DATE: Mar/30/99 

KEYWORDS:  Seating problems may be encountered when adding Ultra Enterprise 450
           internal disk drives.


---------------------------------------------------------------------
        - Sun Proprietary/Confidential: Internal Use Only -
---------------------------------------------------------------------  
                        FIELD INFORMATION NOTICE
                  (For Authorized Distribution by SunService)



SYNOPSIS:  Seating problems may be encountered when adding Ultra
           Enterprise 450 internal disk drives.
 		

TOP FIN/FCO REPORT: No
 
PRODUCT_REFERENCE:  E450 Internal disk seating  
                                                                               
  
PRODUCT CATEGORY:   Server / Disk

PRODUCTS AFFECTED:  	
 
Mkt_ID   Platform   Model   Description     Serial Number
------   --------   -----   -----------     -------------
Systems Affected
----------------

   -     E450       ALL     Ultra Enterprise 450           -
   -     E450       ALL     Ultra 450                      -

X-Options Affected
------------------

X5229A    -          -      OPT INT DISK 9.1GB/7200 USCSI  -
X5214A    -          -      OPT INT DISK 4.2GB/7200 USCSI  -


PART NUMBERS AFFECTED: 

Part Number   Description                     Model
-----------   -----------                     -----
540-3704-01   9GB 7200RPM 1" DRV W/SPUD BRKT    -
540-2938-02   ASSY,4GB USCSI W/SPUD 7200RPM     -
F540-3704-01  FRU,9GB 7200RPM 1"DR              -
F540-2938-02  FRU,4GB USCSI W/SPUD              -


REFERENCES: 

MANUAL: 805-0429-10  Ultra Enterprise 450 Server Owner's Guide
MANUAL: 805-0430-10  Sun Ultra 450 Workstation Owner's Guide

	
PROBLEM DESCRIPTION: 

Customers and Field Service Representatives that install X-option
add-on disk drives or who are replacing an existing internal Ultra
Enterprise 450 drive FRU, (described above) may experience a problem
with the seating of the newly installed disk drive(s).

Reports of this problem are very sparse, however, if the seating
problem is encountered, the following symptom will be apparent after
the internal disk drive(s) has been installed:

1. The "probe SCSI" command will NOT reveal the target ID of the newly
   installed disk drive.

2. The green LED that corresponds to the installed disk drive will NOT
   be illuminated.

Currently this problem appears to be related to a backplane flexing 
problem which results in the disk backplane flexing away from the drive
connector upon insertion, thus causing the disk drive(s) not to be seen
with the probe-scsi-all command.	


IMPLEMENTATION: 
 
         ---
    	|   |  	MANDATORY (Fully Pro-Active)
  	 ---    
  	 
  
         ---
    	|   | 	CONTROLLED PRO-ACTIVE (per Sun Geo Plan) 
  	 --- 
  	 
  	   			
         ---
    	| X | 	REACTIVE (As Required)
  	 ---


	
CORRECTIVE ACTION: 
		

Customers and Field Service Representatives that install X-option
add-on disk drives or who are replacing an existing internal Ultra
Enterprise 450 drive FRU can avoid the above mentioned internal disk
drive seating problem by following the drive installation recommend-
ation shown below:

1. Open the bottom door.

   This door covers the lower part of the system's front panel and is
   hinged on the left side.  Unlock the door, if necessary, pull firmly
   on the right side of this door and swing it out and to the left.

2. Align the drive with its drive bay opening.

   If you are installing the drive as a new option, install it in the
   lowest available slot number.  Verify that a disk backplane is
   installed behind the selected  drive bay.

   Orient the drive so that the handle's hinge is on the left and the
   handle is open (extended).  Slide the handle latch to the right to
   open the handle.

3. Fit the drive into the guide rails on each side of the drive bay.

4. Slide the disk drive into the drive bay until the handle contacts
   the disk cage.

5. Swing the drive handle closed until it latches.

  NOTE. After the drive handle is closed and latched, give the drive
        and extra push to ensure that full contact of the connectors is
        achieved.

Closing the handle engages the drive with it's backplane connectors.
If the system power is on, the green LED beside the disk slot will
light to indicate that the drive is properly inserted.

Repeat steps 2 through 5 for any other drives that need to be
replaced.
           
  
COMMENTS: 

For additional information on the installation of internal drives
on the E450 please reference the Ultra 450 Workstation Owner's
Guide.

--------------------------------------------------------------------------

Implementation Footnote:
________________________

i)   In case of MANDATORY FINs, Enterprise Services will attempt to contact   
     all affected customers to recommend implementation of the FIN. 
        

ii)  For CONTROLLED PROACTIVE FINs, Enterprise Services mission critical sup-  

     port teams will recommend implementation of the FIN (to their respective 
     accounts), at the convenience of the customer. 


iii) For REACTIVE FINs, Enterprise Services will implement the FIN as the need 

     arises.

-----------------------------------------------------------------------
 
All released FINs and FCOs can be accessed using your favorite network 
browser as follows:
 
SunWeb Access: 
______________
 
* Access the top level URL of http://cte.corp/FIN_FCO/

* From there, select the appropriate link to query or browse the FIN and
  FCO Homepage collections.
 
SunSolve Online Access:
_______________________
 
* Access the SunSolve Online URL at http://sunsolve.Corp/

* From there, select the appropriate link to browse the FIN or FCO index.

Supporting Documents:
____________________
 
Supporting documents for FIN/FCOs can be found on Edist.  Edist can be 
accessed internally at the following URL: http://edist.corp/.
  
* From there, follow the hyperlink path of "SunService Documentation"
and 
  click on "FIN & FCO attachments", then choose the appropriate
folder,  
  FIN or FCO.  This will display supporting directories/files for FINs or
  FCOs.
   
Internet Access:
_______________
 
* Access the top level URL of https://infoserver.Sun.COM
 
--------------------------------------------------------------------------
    
General:
________

Send questions or comments to finfco-manager@cte.Corp

---------------------------------------------------------------------------



Copyright (c) 1997-2003 Sun Microsystems, Inc.