Document fins/I0668-1


FIN #: I0668-1

SYNOPSIS: LOM problem on Netra X1 systems

DATE: Apr/27/01

KEYWORDS: LOM problem on Netra X1 systems


---------------------------------------------------------------------
- Sun Proprietary/Confidential: Internal Use Only -
---------------------------------------------------------------------  
                            FIELD INFORMATION NOTICE
                  (For Authorized Distribution by SunService)



SYNOPSIS: If Lights Out Management (LOM) firmware V3.8 or lower is installed, 
          it may cause fan speed problem on early Netra X1 systems.
 

TOP FIN/FCO REPORT: No 
 
PRODUCT_REFERENCE:  Netra X1 with LOM Firmware V3.8 or lower  
 
PRODUCT CATEGORY:   Server / Service


PRODUCTS AFFECTED:  
 
Mkt_ID        Platform   Model   Description              Serial Number
------        --------   -----   -----------              -------------
Systems Affected
----------------
  -             N19       ALL    Netra X1 400Mhz Server         -
 
X-Options Affected
------------------
  -               -        -           -                        -


PART NUMBERS AFFECTED: 

Part Number        Description                       Model
-----------        -----------                       -----
375-0132-02        ASSY,OEM,MOTHERBOARD,W/CPU,FJ2      -
375-3015-03        ASSY,OEM,MOTHERBOARD,W/CPU,FJL      -


REFERENCES:

BugId:    4410715 - Fan speed not based at 50% for temperatures lower 
                    than 15degC.

PatchId:  110208: Netra Lights Out Management 2.0 patch.

ECO:      WO_20362
          WO_20446 

      
PROBLEM DESCRIPTION: 
 
On early Netra X1 units with Lights Out Management (LOM) Firmware
version V3.8 or lower, the  system may occasionally report that the fan
is running too slowly when the system is powered up for the first
time.  If this happens, the LOM system will turn the server's 'Fault'
LED on, blinking.  However, the impact to the customer is minimal and
can be rectified from console.  See instructions in Corrective action.

The problem is related to the environmental as it can be seen in units
that are being powered up at low temperature ~ 2 degrees C or have been
shipped via air freight and powered up for the first time from the
manufacturer's factory.  Failure has not been observed at ambient room
temp or on systems allowed to acclimate to room temp over a period of
time.

Failing configuration is any Netra X1 that is being powered up for the
first time from shipping or storage with LOM Firmware version V3.8 or
lower.  Symptom Identification is that the LOM system will turn the 
server's 'Fault' LED on, blinking upon initial power up.

Typical error message: 

   LOM event: +0h2m44s Fan 1 FATAL FAULT: failed 44%
 
The minimum allowable speed of the fan is determined by it's minimum
operating voltage.  This translates to a minimum drive waveform
mark-space ratio of 0.3.  The LOM is letting this drop to 0.21 as it
ramps the fan speed down at lower temperatures, thus the fan is
significantly under driven at cold temperature and the LOM reports the
error.

The LOM code driving the fan needs to be reprogrammed.  This is a long
term fix and will be available in the respun LOM patch 110208.

Three steps are being taken.

1. A one page warning document is being shipped along with new systems at
   Sun Manufacturing.  WO_20362 will release this. Text is detailed in the
   corrective action.  This FIN will serve the same purpose.
 
2. The LOM FW is being re written to incorporate the fix.  This will be 
   released to Sun Manufacturing for cut-in ASAP as V3.10 in the 375-0132-03
   or 375-3015-04 part via ECO WO_20446. 

3. The LOM patch 110208 has been respun and now available on Sunsolve       
   since April 12 2001. 


IMPLEMENTATION:  
 
         ---
        |   |   MANDATORY (Fully Pro-Active)
         ---    
         
  
         ---
        |   |   CONTROLLED PRO-ACTIVE (per Sun Geo Plan) 
         --- 
         
                                
         ---
        | X |   REACTIVE (As Required)
         ---
         

CORRECTIVE ACTION: 

The following recommendation is provided as a guideline for authorized
Enterprise Services Field Representatives who may be encountering the
above mentioned problem.

1) Check which LOM version is installed from the LOM prompt.

     lom> version

   Then the screen will display with the following.

     LOM version:     v3.x 

 OR

   Check which LOM version is installed from the Solaris # prompt. 

     # lom -c | grep version

   Then the screen will display with the following.
 
     firmware version=3.x

2) If the version is 3.8 or lower, install PatchId #110208-09.  
 
         
COMMENTS:  

--------------------------------------------------------------------------

Implementation Footnote:

i)   In case of MANDATORY FINs, Enterprise Services will attempt to    
     contact all affected customers to recommend implementation of 
     the FIN. 
   
ii)  For CONTROLLED PROACTIVE FINs, Enterprise Services mission critical    
     support teams will recommend implementation of the FIN  (to their  
     respective accounts), at the convenience of the customer. 

iii) For REACTIVE FINs, Enterprise Services will implement the FIN as the   
     need arises.
---------------------------------------------------------------------------
-
All released FINs and FCOs can be accessed using your favorite network 
browser as follows:
 
SunWeb Access:
-------------- 
* Access the top level URL of http://sdpsweb.ebay/FIN_FCO/

* From there, select the appropriate link to query or browse the FIN and
  FCO Homepage collections.
 
SunSolve Online Access:
-----------------------
* Access the SunSolve Online URL at http://sunsolve.Corp/

* From there, select the appropriate link to browse the FIN or FCO index.

Supporting Documents:
---------------------
* Supporting documents for FIN/FCOs can be found on Edist.  Edist can be 
  accessed internally at the following URL: http://edist.corp/.
  
* From there, follow the hyperlink path of "Enterprise Services Documenta- 
  tion" and click on "FIN & FCO attachments", then choose the
appropriate   
  folder, FIN or FCO.  This will display supporting directories/files for 
  FINs or FCOs.
   
Internet Access:
----------------