Document fins/I0681-1


FIN #: I0681-1

SYNOPSIS: Payflex smart card problem with Sun Ray server S/W 1.0 or 1.1

DATE: Jun/12/01

KEYWORDS: Payflex smart card problem with Sun Ray server S/W 1.0 or 1.1


---------------------------------------------------------------------
- Sun Proprietary/Confidential: Internal Use Only -
---------------------------------------------------------------------  
                            FIELD INFORMATION NOTICE
                  (For Authorized Distribution by SunService)


 
SYNOPSIS: If using Sun Ray server S/W 1.0 or 1.1, the hotdesking with
          Payflex smart cards will not be recognized. 
 
 
SunAlert:           No

TOP FIN/FCO REPORT: No
 
PRODUCT_REFERENCE:  Sun Ray Server Software 1.0/1.1
 
PRODUCT CATEGORY:   Server / Service

 
PRODUCTS AFFECTED:  
 
Mkt_ID   Platform   Model   Description                 Serial Number
------   --------   -----   -----------                 -------------
Systems Affected
----------------
  -      Sun Ray      -     Sun Ray 1, 100, 150               -
 
X-Options Affected
------------------
x1403A     -          -     Payflex Smart Card w/ art         -
x1404A     -          -     Payflex Smart Card Blank          -
 

PART NUMBERS AFFECTED:
 
Part Number   Description                       Model
-----------   -----------                       -----
595-5763-01   Payflex Smart Card w/ art           -
595-5764-01   Payflex Smart Card Blank            -


REFERENCES: 
 
BugId:   4355989 - Sun Ray firmware does not recognize new type MicroPayflex 
                   and Payflex cards.

PatchId: 109127 - Sun Ray Enterprise Server version 1.1 Update Patch.
         108303 - Sun Ray Enterprise Server version 1.0 Update Patch.


PROBLEM DESCRIPTION:
 
Users will not be able to utilize the Hotdesking feature of Sun Ray
systems shipped prior to October 2000 with newer type Payflex and
MicroPayflex smart cards if the systems are running Sun Ray Server
software 1.0 or 1.1.  Hotdesking is the feature that allows users to
access their desktop sessions from any Sun Ray appliance within their
workgroup.  The newer Payflex and MicroPayflex cards will not initiate
a user session, although users may still login without the smart card. 

When the user inserts one of the  new smart cards into the slot, the
"Unrecognized Card" icon will be displayed and the user will not be
able to access any Sun Ray sessions.

Newer MicroPayflex and Payflex cards identify themselves to the system 
differently than the older cards.  They utilize a new encoding format.
New code has been written into the Sun Ray Server Software to recognize 
the new cards.  The Sun Ray firmware must be updated via a patch to allow 
it to recognize the new cards.  

The version of MicroPayflex card which was originally supported was EOLed by 
the card manufacturer.  The Sun Ray engineering group has added a fix to the 
software to support the new MicroPayflex card and the Payflex card.

Sun Ray Server Software version 1.2 and any subsequent versions will contain 
the fix for this problem.  Users who wish to continue to use Sun Ray Server 
Software 1.0 or 1.1 can download patch ID  108303 or 109127.


IMPLEMENTATION: 
 
          ---
         |   |   MANDATORY (Fully Pro-Active)
          ---
 
 
          ---
         |   |   CONTROLLED PRO-ACTIVE (per Sun Geo Plan)
          ---
 

          ---
         | X |   REACTIVE (As Required)
          ---
 
 
CORRECTIVE ACTION:
 
The following recommendation is provided as a guideline for authorized
Enterprise Services Field Representatives who may encounter the above 
mentioned problem:

For customers who need the hotdesking with payflex smart card on Sun Ray
Servers, please perform the following guideline:

1) Obtain the applicable patches from the following website:

   A) For Sun Ray Server Software 1.0 users, install patchId# 108303.

  OR

   B) For Sun Ray Server Software 1.1 users, install patchId# 109127.  
 
 
COMMENTS: 

None
 
============================================================================
 
Implementation Footnote:
 
i)   In case of MANDATORY FINs, Enterprise Services will attempt to
     contact all affected customers to recommend implementation of
     the FIN.
 
ii)  For CONTROLLED PROACTIVE FINs, Enterprise Services mission critical
     support teams will recommend implementation of the FIN  (to their
     respective accounts), at the convenience of the customer.
 
iii) For REACTIVE FINs, Enterprise Services will implement the FIN as the
     need arises.
----------------------------------------------------------------------------
All released FINs and FCOs can be accessed using your favorite network
browser as follows:
 
SunWeb Access:
--------------
* Access the top level URL of http://sdpsweb.ebay/FIN_FCO/
 
* From there, select the appropriate link to query or browse the FIN and
  FCO Homepage collections.
 
SunSolve Online Access:
-----------------------
* Access the SunSolve Online URL at http://sunsolve.Corp/
 
* From there, select the appropriate link to browse the FIN or FCO index.
 
Supporting Documents:
---------------------
* Supporting documents for FIN/FCOs can be found on Edist.  Edist can be
  accessed internally at the following URL: http://edist.corp/.

* From there, follow the hyperlink path of "Enterprise Services Documenta-
  tion" and click on "FIN & FCO attachments", then choose the
appropriate
  folder, FIN or FCO.  This will display supporting directories/files for
  FINs or FCOs.
 
Internet Access:
----------------
* Access the top level URL of https://infoserver.Sun.COM
--------------------------------------------------------------------------
General:
--------
* Send questions or comments to finfco-manager@Sun.COM
---------------------------------------------------------------------------
 



------------- End Forwarded Message -------------



Copyright (c) 1997-2003 Sun Microsystems, Inc.