Document fins/I0815-1


FIN #: I0815-1

SYNOPSIS: Sun Fire 6800/4810/4800/3800 Firmware Compatibility Matrix

DATE: Apr/30/02

KEYWORDS: Sun Fire 6800/4810/4800/3800 Firmware Compatibility Matrix


---------------------------------------------------------------------
- Sun Proprietary/Confidential: Internal Use Only -
---------------------------------------------------------------------  
                            FIELD INFORMATION NOTICE
                  (For Authorized Distribution by SunService)

                                    

SYNOPSIS: Sun Fire 6800/4810/4800/3800 Firmware Compatibility Matrix.


Sun Alert:          Yes

TOP FIN/FCO REPORT: No

PRODUCT_REFERENCE:  Serengeti F/W Matrix

PRODUCT CATEGORY:   Service / Service


PRODUCTS AFFECTED:  

Systems Affected: 
----------------
Mkt_ID   Platform   Model   Description        Serial Number
------   --------   -----   -----------        -------------
  -        S8        ALL    Sun Fire 3800            -
  -        S12       ALL    Sun Fire 4800            -
  -        S12i      ALL    Sun Fire 4810            -
  -        S24       ALL    Sun Fire 6800            -


List X-Options affected:
-----------------------
Mkt_ID      Platform   Model   Description     Serial Number
------      --------   -----   -----------     -------------
  -            -         -          -                -


Part Number     Description     Model  
-----------     -----------     -----
     -               -            - 


REFERENCES:
 
PatchId: 112127 or later - Hardware/PROM: Sun Fire 3800/4800/4810/6800
                              Systems flashprom update.
         111346 or later - Hardware/PROM: Sun Fire 3800/4800/4810/6800 
                              Systems flashprom update.
         112127 or later - Hardware/PROM: Sun Fire 3800/4800/4810/6800 
                              Systems flashprom update.
         
FIN:     I0731-1
 
SUN ALERT:  41007

MANUAL: 805-7373-13 - Sun Fire 6800/4810/4800/3800 Systems Platform 
                      Administration Manual.
        816-3885-10 - Sun Fire 6800/4810/4800/3800 System Software 
                      Release Notes.
        806-6783-10 - Sun Fire 6800, 4810, 4800, and 3800 Systems 
                      Dynamic Reconfiguration User Guide.

URL: http://cpre-amer.west/esg/msg/techinfo/platform/sun_fire/firmware-matrix/

     
PROBLEM DESCRIPTION:  

A number of significant firmware upgrades have become available on
the Sun Fire 6800/4810/4800/3800 product line.  This FIN is to
document recommended levels of the firmware and identify compatibility
between the Solaris OS releases and the Sun Fire 6800/4810/4800/3800
firmware releases.  
   
The information provided here should be very helpful to service
personnel who need a convenient and authoritative reference source for
Sun Fire 6800/4810/4800/3800 firmware releases.  This FIN also intends
to influence customer adoption of new firmware versions and minimum
firmware versions.

CPRE has provided a Firmware Compatibility Matrix at the following URL:

   http://cpre-amer.west/esg/msg/techinfo/platform/sun_fire/firmware-matrix/

This matrix documents compatibilities among the Sun Fire
6800/4810/4800/3800 system controller firmware, system board firmware,
Solaris OS releases, dynamic system reconfiguration support and
CPU/Memory boards.  In addition, lists of the bugs fixed by the
different firmware versions are provided.

The current version of the firmware matrix is shown below.  In the
future, the URL provided above should be accessed for information on
the latest firmware.

   -----------------------------------------------------------------------  
  | SC FW   |   BD FW    |                | Supports Dynamic | CPU/Memory | 
  | version |   version  |    Domain OS   | Recofiguration?  | Board      |
  |=======================================================================|
  | ** 5.11.x **                                                          |
  |-----------------------------------------------------------------------|
  | 5.11.4  |   5.11.x   |    S8U4, S8U5  |       No         | UltraSPARC |
  |         |            |    S8U6        |                  | 750        |
  |---------+------------+----------------+------------------+------------|
  | 5.11.6  |   5.11.x   |    S8U4, S8U5, |       No         | UltraSPARC |
  |         |            |    S8U6        |                  | 750        |
  |---------+------------+----------------+------------------+------------|
  | 5.11.7  |   5.11.x   |    S8U4, S8U5, |       No         | UltraSPARC |
  |         |            |    S8U6        |                  | 750        |
  |---------+------------+----------------+------------------+------------|
  | 5.11.9  |   5.11.x   |    S8U4, S8U5, |       No         | UltraSPARC |
  |         |            |    S8U6        |                  | 750        |
   -----------------------------------------------------------------------

 NOTE:  Firmware version 5.11.9 (Patch 111346) is the minimum 
        recommended firmware version of 5.11.x. 

   -----------------------------------------------------------------------  
  | SC FW   |   BD FW    |                | Supports Dynamic | CPU/Memory | 
  | version |   version  |    Domain OS   | Recofiguration?  | Board      |
  |=======================================================================|
  | ** 5.12.5 **                                                          |
  |-----------------------------------------------------------------------|
  | 5.12.5  |   5.12.x   |    S8U4, S8U5  |       No         | UltraSPARC |
  |         |            |                |                  | 750        |
  |---------+------------+----------------+------------------+------------|
  | 5.12.5  |   5.12.x   |    S8U6        |       No         | UltraSPARC |
  |         |            |                |                  | 750, 900   |
   -----------------------------------------------------------------------

 NOTE: As of the release date for 5.12.6, Patch 112127-xx been revised
       to include the features and bug fixes for firmware 5.12.6.  The
       patch for 5.12.5 is no longer being distributed.

   --------------------------------------------------------------------  
  | SC FW   |  BD FW    |              | Supports Dynamic | CPU/Memory | 
  | version |  version  |  Domain OS   | Recofiguration?  | Board      |
  |====================================================================|
  | ** 5.12.6 **                                                       |
  |--------------------------------------------------------------------|
  | 5.12.6  |  5.12.x   |  S8U4, S8U5  |      No          | UltraSPARC |
  |         |           |              |                  | 750        |
  |---------+-----------+--------------+------------------+------------|
  | 5.12.6  |  5.12.x   |  S8U6        |      No          | UltraSPARC |
  |         |           |              |                  | 750, 900   |
  |---------+-----------+--------------+------------------+------------|
  | 5.12.6  |  5.12.x   |  S8U7        |      Yes         | UltraSPARC |
  |         |           |              |                  | 750. 900   |
   ---------+-----------+--------------+------------------+------------    

 NOTE: 5.11.x means any version that starts with the numbering: 5.11.
       5.12.x means any version that starts with the numbering: 5.12.
       
It is strongly recommended that all system boards be upgraded to the
same version of firmware.  While most system boards may be used with
different versions of firmware, product quality testing is performed
with uniform versions of firmware installed on all system boards.
      
Each firmware patch (currently 112127-xx and 111346-xx) ships with an
Install.info file.  This file provides complete instructions for
determining current firmware levels and performing firmware updates.


IMPLEMENTATION: 

         ---
        |   |   MANDATORY (Fully Proactive)
         ---    
         
  
         ---
        |   |   CONTROLLED PROACTIVE (per Sun Geo Plan) 
         --- 
         
                                
         ---
        | X |   REACTIVE (As Required)
         ---
         

CORRECTIVE ACTION:

The following recommendation is provided as a guideline for authorized
Enterprise Services Field Representatives who may encounter the above
mentioned problem.

1) Access the following CPRE web site for information on the
   latest firmware levels and patch versions available for Sun Fire
   6800/4810/4800/3800 systems.
   
   http://cpre-amer.west/esg/msg/techinfo/platform/sun_fire/firmware-matrix/
   
2) Firmware versions should be checked at system installation, during
   hardware upgrades, or after FRU replacement.  It is strongly recommended 
   that all system boards contain the same version of firmware.  Service
   personnel are encouraged to install the most current firmware
   version on new installations when approved by the customer
   representatives.
 
   
3) Use the instructions provided with the Install.info file for each 
   firmware patch to verify and update firmware.     


COMMENTS:

Firmware upgrades will be scheduled as desired by customers.  Customers
are responsible for maintaining Solaris OS and system firmware on
their servers.

============================================================================

Implementation Footnote:

i)   In case of MANDATORY FINs, Enterprise Services will attempt to
     contact all affected customers to recommend implementation of
     the FIN.

ii)  For CONTROLLED PROACTIVE FINs, Enterprise Services mission critical

     support teams will recommend implementation of the FIN  (to their
     respective accounts), at the convenience of the customer.

iii) For REACTIVE FINs, Enterprise Services will implement the FIN as
the
     need arises.
----------------------------------------------------------------------------

All released FINs and FCOs can be accessed using your favorite network
browser as follows:

SunWeb Access:
--------------
* Access the top level URL of http://sdpsweb.ebay/FIN_FCO/

* From there, select the appropriate link to query or browse the FIN and

  FCO Homepage collections.

SunSolve Online Access:
-----------------------
* Access the SunSolve Online URL at http://sunsolve.Corp/

* From there, select the appropriate link to browse the FIN or FCO
index.

Internet Access:
----------------
* Access the top level URL of https://infoserver.Sun.COM
--------------------------------------------------------------------------

General:
--------
* Send questions or comments to finfco-manager@sdpsweb.EBay
--------------------------------------------------------------------------


Copyright (c) 1997-2003 Sun Microsystems, Inc.