InfoDoc ID |
|
Synopsis |
|
Date |
21180 |
|
Decode of T3 / Purple Loop (Firmware Status) Codes. |
|
31 May 2000 |
This chart provides the decode of the numbers that are displayed at
the end of the "firmware status =" message. This code is output from
the Qlogic ISP 2100 controllers. These messges can be observed on the
T3 / Purple RS232 admin (COM) port during a T3 / Purple boot up.
eg.
Initializing loop 1 ISP2100 ... firmware status = 3
Detected 19 FC-AL ports on loop 1
Initializing loop 2 ISP2100 ... firmware status = 3
etc
The decode of the firmware status code numbers is as follows ...
----------------------------------------------------------------------------
| Loop Status (FW Status)| Description |
----------------------------------------------------------------------------
| 0 | Not initialized |
----------------------------------------------------------------------------
| 1 | Loop initialization in progress |
----------------------------------------------------------------------------
| 2 | Port/process login in progress |
----------------------------------------------------------------------------
| 3 | Operational |
----------------------------------------------------------------------------
| 4 | Loss of sync detected, attempting to resync |
----------------------------------------------------------------------------
| 5 | Unrecoverable error |
----------------------------------------------------------------------------
| 6 | Re-initialization in progress |
----------------------------------------------------------------------------
| 7 | AL-PA not acquired on last loop initialization |
----------------------------------------------------------------------------
INTERNAL SUMMARY:
This firmware status information may help in with front and back end
Purple FC-AL diagnosis
SUBMITTER: Ross Keeley
APPLIES TO: AFO Vertical Team Docs/Storage, Hardware/Disk Storage Subsystem/StorEdge Disk Array/StorEdge T3
ATTACHMENTS:
Copyright (c) 1997-2003 Sun Microsystems, Inc.