InfoDoc ID   Synopsis   Date
21180   Decode of T3 / Purple Loop (Firmware Status) Codes.   31 May 2000

Status Issued

Description
This chart provides the decode of the numbers that are displayed at 
the end of the "firmware status =" message. This code is output from 
the Qlogic ISP 2100 controllers. These messges can be observed on the 
T3 / Purple RS232 admin (COM) port during a T3 / Purple boot up.

eg.

Initializing loop 1 ISP2100 ... firmware status = 3
Detected 19 FC-AL ports on loop 1
Initializing loop 2 ISP2100 ... firmware status = 3
etc

The decode of the firmware status code numbers is as follows ...

----------------------------------------------------------------------------
| Loop Status (FW Status)|    Description				   |
----------------------------------------------------------------------------
|           0            |  Not initialized				   |
----------------------------------------------------------------------------
|           1            |  Loop initialization in progress		   |
----------------------------------------------------------------------------
|           2            |  Port/process login in progress		   |
----------------------------------------------------------------------------
|           3            |  Operational					   |
----------------------------------------------------------------------------
|           4            |  Loss of sync detected, attempting to resync	   |		
----------------------------------------------------------------------------
|           5            |  Unrecoverable error				   |
----------------------------------------------------------------------------
|           6            |  Re-initialization in progress		   |
----------------------------------------------------------------------------
|           7            |  AL-PA not acquired on last loop initialization |
----------------------------------------------------------------------------      
INTERNAL SUMMARY:
This firmware status information may help in with front and back end 
Purple FC-AL diagnosis      
SUBMITTER: Ross Keeley APPLIES TO: AFO Vertical Team Docs/Storage, Hardware/Disk Storage Subsystem/StorEdge Disk Array/StorEdge T3 ATTACHMENTS:


Copyright (c) 1997-2003 Sun Microsystems, Inc.