InfoDoc ID   Synopsis   Date
21216   Device Paths of Ultra [TM] 5, 10, 30, 60, Ultra Enterprise (UE) 250 and UE450, Sun Blade [TM] 1000   27 Nov 2002

Status Issued

Description
The device paths shown for each system type below are how Solaris
recognizes the device.  At the Open Boot PROM (OBP), the device name
may be slightly different.  Typically, the OBP uses `disk' and 
`cdrom' aliases for the boot disk and cdrom drive, where Solaris may 
use a different name/alias for the same device.  The overall device
path is the same for both OBP and Solaris, the difference is 
seen at the device position at the end of the path.

Ultra 5 Device Paths
    PCI Slot #1                 /pci@1f,0/pci@1/pci@1/<device>@1,* 
    PCI Slot #2                	/pci@1f,0/pci@1/pci@2/<device>@2,* 
    PCI Slot #3                	/pci@1f,0/pci@1/pci@3/<device>@3,* 
    Internal Disk            	/pci@1f,0/pci@1,1/ide@3/dad@0,0 
    Internal CDROM        	/pci@1f,0/pci@1,1/ide@3/sd@2,0

Ultra 10 Device Paths
    PCI Slot #1                 /pci@1f,0/pci@1/pci@1/<device>@1,* 
    PCI Slot #2                	/pci@1f,0/pci@1/pci@2/<device>@2,* 
    PCI Slot #3                	/pci@1f,0/pci@1/pci@3/<device>@3,* 
    PCI Slot #4                	/pci@1f,0/pci@1/pci@4/<device>@4,*
    Internal Disk 0             /pci@1f,0/pci@1,1/ide@3/dad@0,0 
    Internal Disk 1		/pci@1f,0/pci@1,1/ide@3/dad@1,0
    Internal CDROM         	/pci@1f,0/pci@1,1/ide@3/sd@2,0                                                                                     

Ultra 30, NETRA t 1100 Device Paths
    PCI Slot #1              	/pci@1f,2000/<device>@1,* 
    PCI Slot #2               	/pci@1f,4000/<device>@2,* 
    PCI Slot #3               	/pci@1f,4000/<device>@4,* 
    PCI Slot #4               	/pci@1f,4000/<device>@5,* 
    Internal Disk            	/pci@1f,4000/scsi@3/sd@0,0 
    Internal CDROM        	/pci@1f,4000/scsi@3/sd@6,0 
    External SCSI Port     	/pci@1f,4000/scsi@3,1/<device> 

Ultra 60, 220R, NETRA t 1120/1125 Device Paths
    PCI Slot #1               	/pci@1f,2000/<device>@1,* 
    PCI Slot #2               	/pci@1f,4000/<device>@2,* 
    PCI Slot #3               	/pci@1f,4000/<device>@4,* 
    PCI Slot #4               	/pci@1f,4000/<device>@5,* 
    Internal Disk            	/pci@1f,4000/scsi@3/sd@0,0 
    Internal CDROM        	/pci@1f,4000/scsi@3/sd@6,0 
    External SCSI Port     	/pci@1f,4000/scsi@3,1/<device> 

Ultra 80, 420R, NETRA t 1400/1405 Device Paths
    PCI Slot #1               	/pci@1f,2000/<device>@1,* 
    PCI Slot #2               	/pci@1f,4000/<device>@4,* 
    PCI Slot #3               	/pci@1f,4000/<device>@2,* 
    PCI Slot #4               	/pci@1f,4000/<device>@5,* 
    Internal Disk            	/pci@1f,4000/scsi@3/sd@0,0 
    Internal CDROM        	/pci@1f,4000/scsi@3/sd@6,0 
    External SCSI Port     	/pci@1f,4000/scsi@3,1/<device> 
   
Ultra Enterprise 250 Device Paths
    PCI Slot #0              	/pci@1f,4000/<device>@5,* 
    PCI Slot #1              	/pci@1f,4000/<device>@4,*
    PCI Slot #2              	/pci@1f,4000/<device>@2,* 
    PCI Slot #3               	/pci@1f,2000/<device>@1,* 
    Internal Disk Slot #0 	/pci@1f,4000/scsi@3/sd@0 
    Internal Disk Slot #1 	/pci@1f,4000/scsi@3/sd@8 
    Internal Disk Slot #2 	/pci@1f,4000/scsi@3/sd@9 
    Internal Disk Slot #3 	/pci@1f,4000/scsi@3/sd@a 
    Internal Disk Slot #4 	/pci@1f,4000/scsi@3/sd@b 
    Internal Disk Slot #5 	/pci@1f,4000/scsi@3/sd@c 
    Internal CDROM        	/pci@1f,4000/scsi@3/sd@6,0 
    External SCSI Port    	/pci@1f,4000/scsi@3,1/<device> 

Ultra Enterprise 450 Device Paths
    PCI Slot #1              	/pci@6,4000/<device>@4,* 
    PCI Slot #2              	/pci@6,4000/<device>@3,* 
    PCI Slot #3              	/pci@6,4000/<device>@2,* 
    PCI Slot #4              	/pci@6,2000/<device>@1,* 
    PCI Slot #5              	/pci@1f,2000/<device>@1,* 
    PCI Slot #6              	/pci@4,2000/<device>@1,* 
    PCI Slot #7              	/pci@4,4000/<device>@4,* 
    PCI Slot #8              	/pci@4,4000/<device>@3,* 
    PCI Slot #9              	/pci@4,4000/<device>@2,* 
    PCI Slot #10             	/pci@1f,4000/<device>@4,* 
    Internal CDROM        	/pci@1f,4000/scsi@2/sd@6,0 
    External SCSI Port     	/pci@1f,4000/scsi@2/<device> 
    Internal 4 disk backplane	/pc1@1f,4000/scsi@3

Note:  see Infodoc# 16735 for useful information about setting
the OBP parameter disk-led-assoc variable to easily translate
device paths to internal disk slot numbers in a UE450.                                    

Sun Blade 100
    PCI Slot #1                 /pci@1f,0/pci@5/<device>@2,*
    PCI slot #2                 /pci@1f,0/pci@5/<device>@1,*
    PCI Solt #3                 /pci@1f,0/pci@5/<device>@0,*
    primary ide master          /pci@1f,0/ide@d/dad@0,0       (default boot)
    primary ide slave           /pci@1f,0/ide@d/<device>@1,0  (default cdrom)
    secondary ide master        /pci@1f,0/ide@d/sd@2,0       
    secondary ide slave         /pci@1f,0/ide@d/<device>@3,0
    environmental monitor &
       card reader              /pci@1f,0/pmu@3/<path>
    proms                       /pci@1f,0/ebus@c,3/<usb device>
    internal graphics           /pci@1f,0/SUNW,m64B@13
    USB ports                   /pci@1f,0/usb@c,3/<usb device>

Sun Blade 150
    PCI Slot #1                 /pci@1f,0/<device>@2,*
    PCI slot #2                 /pci@1f,0/<device>@1,*
    PCI Solt #3                 /pci@1f,0/<device>@3,*
    primary ide master          /pci@1f,0/ide@d/dad@0,0      (default boot)
    primary ide slave           /pci@1f,0/ide@d/<dev>@1,0    (default cdrom)
    secondary ide master        /pci@1f,0/ide@d/sd@2,0       
    secondary ide slave         /pci@1f,0/ide@d/<dev>@3,0
    environmental monitor &
       card reader              /pci@1f,0//pmu@3/<path>
    proms                       /pci@1f,0/ebus@c,3/<usb device>
    internal graphics           /pci@1f,0/SUNW,m64B@13
    USB ports                   /pci@1f,0/usb@c,3/<usb device>
                                                                                      
Sun Blade 1000/2000, Sun Fire 280R, Netra 20 Device Paths
    PCI Slot #1			/pci@8,600000/pci@1,*
    PCI Slot #2			/pci@8,700000/pci@3,* 
    PCI Slot #3			/pci@8,700000/pci@2,*
    PCI Slot #4			/pci@8,700000/pci@1,*
    Internal Hard Drives        /pci@8,600000/SUNW,glc@4/fp@0,0/ssd@<WWN>
    Internal SCSI bus           /pci@8,700000/scsi@6/<device>
      DVD/CDROM                 /pci@8,700000/scsi@6/sd@6,0
      Tape Drive                /pci@8,700000/scsi@6/st@4,0
    External FCAL               /pci@8,600000/SUNW,glc@4/fp@0,8/<device>
    External SCSI Port		/pci@8,700000/scsi@6,1/<device>
    External USB                /pci@8,700000/usb@5,3/<device> 

Sun Fire v100
    Int CDROM                   /pci@1f,0/ide@d/sd@3,0
    primary ide master          /pci@1f,0/ide@d/<device@0,0
    primary ide slave           /pci@1f,0/ide@d/<device>@1,0
    secondary ide master        /pci@1f,0/ide@d/dad@2,0        (default boot)
    secondary ide slave         /pci@1f,0/ide@d/sd@3,0         (default CD)
    Network                     /pci@1f,0/pci@1,1/<network>@c,1
                                /pci@1f,0/pci@1,1/<network>@5,1

Sun Fire v120 / Netra 120
    PCI slot #0                 /pci@1f,0/pci@1,1/<device>@1,*
    Int CDROM                   /pci@1f,0/pci@1,1/ide@d/sd@0,0
    Int HDDs                    /pci@1f,0/pci@1,1/scsi@8,1/sd@0,0
                                /pci@1f,0/pci@1,1/scsi@8,1/sd@1,0
    Network #1                  /pci@1f,0/pci@1,1/<network>@c,1
    Network #2                  /pci@1f,0/pci@1,1/<network>@5,1

Sun Fire v480
    PCI Slot #0                 /pci@8,600000/<device>@1,*
    PCI Slot #1                 /pci@8,600000/<device>@2,*
    PCI Slot #2                 /pci@8,700000/<device>@2,*
    PCI Slot #3                 /pci@8,700000/<device>@3,*
    PCI Slot #4                 /pci@8,700000/<device>@4,*
    PCI Slot #5                 /pci@8,700000/<device>@5,*
    DVD/CDROM                   /pci@8,700000/ide@6
    Internal Hard Drives        /pci@8,600000/SUNW,qlc@2/fp@0,0
                                /pci@8,600000/SUNW,qlc@2/fp@1,0
    Network #1                  /pci@9,600000/network@1
    Network #2                  /pci@9,700000/network@2 
    EBUS                        /pci@9,700000/ebus@1
    USB                         /pci@9,700000/usb@1,3

Sun Fire V880
    Gigabit                     /pci@8,600000/network@1
    Onboard FCAL  loopA         /pci@8,600000/SUNW,qlc@2/fp@0,0/ssd@<WWN>,0
                  loopB         /pci@9,600000/pci@1/SUNW,qlc@4/fp@0,0/ssd@<WWN>,0
    Onboard SCSI                /pci@8,700000/scsi@1
    PCI Slot #0                 /pci@8,700000/<device>@5,*
    PCI Slot #1                 /pci@8,700000/<device>@4,*
    PCI Slot #2                 /pci@8,700000/<device>@3,*
    PCI Slot #3                 /pci@8,700000/<device>@2,*
    PCI Slot #4                 /pci@9,700000/<device>@4,*
    PCI Slot #5                 /pci@9,700000/<device>@3,*
    PCI Slot #6                 /pci@9,700000/<device>@2,*
    PCI Slot #7                 /pci@9,600000/<device>@2,*
    PCI Slot #8                 /pci@9,600000/<device>@1,*
    EBUS                        /pci@9,700000/ebus@1/<device>
    Network                     /pci@9,700000/network@1,1/<device>
    USB                         /pci@9,700000/usb@1,3/<device>

Sun Fire 1280

    CDROM                       /ssm@0,0/pci@18,700000/ide@3
    Tape Drive                  /ssm@0,0/pci@18,600000/scsi@2/st@5,0
    Internal Drives             /ssm@0,0/pci@18,600000/scsi@2/sd@0,0
                                /ssm@0,0/pci@18,600000/scsi@2/sd@1,0
    PCI Slot #0                 /ssm@0,0/pci@18,700000/<device>@1,*
    PCI Slot #1                 /ssm@0,0/pci@18,700000/<device>@2,*
    PCI Slot #2                 /ssm@0,0/pci@19,700000/<device>@1,*
    PCI Slot #3                 /ssm@0,0/pci@19,700000/<device>@2,*
    PCI Slot #4                 /ssm@0,0/pci@19,700000/<device>@3,*
    PCI Slot #5                 /ssm@0,0/pci@18,600000/<device>@1,*
    Network #1                  /ssm@0,0/pci@19,600000/network@1
    Network #2                  /ssm@0,0/pci@19,600000/network@2 


This infodoc was recreated and updated by  Anthony Di Torrice and Doug Munson.
updated on 11/22/02.                                                                                                                                                                           
SUBMITTER: Bill Shearer APPLIES TO: Hardware, Hardware/Ultra Enterprise/Servers/Enterprise 450, Hardware/Ultra Enterprise/Servers/Enterprise 250, Hardware/Ultra Enterprise/Servers/Enterprise 10S, Hardware/Ultra Enterprise/Servers/Enterprise 5S, Hardware/Ultra Workstations/Ultra 80, Hardware/Ultra Workstations/Ultra 60, Hardware/Ultra Workstations/Ultra 30, Hardware/Ultra Workstations/Ultra 10, Hardware/Ultra Workstations/Ultra 5, Operating Systems/Solaris/Solaris 2.x, AFO Vertical Team Docs, AFO Vertical Team Docs/Hardware, Hardware/Ultra Workstations/Sun Blade 1000 ATTACHMENTS:


Copyright (c) 1997-2003 Sun Microsystems, Inc.