InfoDoc ID | Synopsis | Date | ||
22747 | probe-scsi-all output for an A1000 | 21 Jun 2000 |
Status | Issued |
Description |
A1000 Hardware RAID box as seen by the system at the PROM level.
Execute the following after the scsi controller is installed, and the A1000 box is powered on....
ok setenv auto-boot? false
ok reset-all
Note: When the machine returns from the reset-all command, it will stop at the "ok" prompt.
ok probe-scsi-all ( The following output is from an E4000 )
/sbus@b,0/QLGC,isp@0,10000
Target 4
Unit 0 Disk Symbios StorEDGE A1000 02053Q38Q'
Unit 1 Device type 20 Symbios StorEDGE A1000 0205 X%p3\w
Unit 2 Device type 20 Symbios StorEDGE A1000 0205 0zo3\w
Unit 3 Device type 20 Symbios StorEDGE A1000 0205 Oo3\w
Unit 4 Device type 20 Symbios StorEDGE A1000 0205 Qp3\w
Unit 5 Device type 20 Symbios StorEDGE A1000 0205 X%p3\w
Unit 6 Device type 20 Symbios StorEDGE A1000 0205 0zo3\w
Unit 7 Device type 20 Symbios StorEDGE A1000 0205 Oo3\w
Note: "Unit 0 Disk Symbios StorEdge A1000" indicates a LUN (logical unit number).
By default the box is shipped with 1 LUN. The other unit numbers indicate possible LUN's.
During boot of the system you see the following message which is normal:
-> WARNING: /sbus@b,0/QLGC,isp@0,10000/sd@4,0 (sd4):
-> corrupt label - wrong magic number
The above warning is normal because we have not yet created and labled the LUN's yet.
Once the RM6 packages and patches are installed, you can then create/label the LUN's and
you should not see the "Warning" message.
The following output shows an A1000 with 3 LUN's constructed....
/sbus@b,0/QLGC,isp@0,10000
Target 4
Unit 0 Disk Symbios StorEDGE A1000 02053Q38Q' <- Default LUN (LUN 0)
Unit 1 Disk Symbios StorEDGE A1000 02053Q48U <- Newly created LUN (LUN 1)
Unit 2 Disk Symbios StorEDGE A1000 02053Q58]c <- Newly created LUN (LUN 2)
Unit 3 Device type 20 Symbios StorEDGE A1000 0205
Unit 4 Device type 20 Symbios StorEDGE A1000 0205
Unit 5 Device type 20 Symbios StorEDGE A1000 0205
Unit 6 Device type 20 Symbios StorEDGE A1000 0205
Unit 7 Device type 20 Symbios StorEDGE A1000 0205
Notice how the "Unit description" changes when new LUN's are created.
INTERNAL SUMMARY:
rene.vega@East.Sun.COM
SUBMITTER: Rene Vega APPLIES TO: Hardware, Hardware/Disk Storage Subsystem/StorEdge Disk Array/StorEdge A1000, AFO Vertical Team Docs, AFO Vertical Team Docs/Hardware ATTACHMENTS: