InfoDoc ID   Synopsis   Date
23571   Compatibility for E10K System Board 501-5693   12 Sep 2000

Status Issued

Description

Compatibility for E10K System Board 501-5693

E10000 system board 501-5693 requires SSP 3.3 and patch 108885-02.

Description

The recent introduction of a new E10000 system board 501-5693 requires a specific level of SSP to take full advantage of a Revision 2 CIC ASIC. The Revision 2 CIC ASIC provides the capability of ECC for DTAG parity errors. This new functionality requires SSP 3.3 and patch 108885-02 to be installed to fully enable the ECC capability.

It is recommended to upgrade to SSP 3.3 and install patch 108885-02 as a preventative measure for the possibility of 501-5693 system board being installed at any point in the future. As always you should check for all recommended patches when updating the SSP level.

Please refer to patch 108885-02 for Installation Issues.

Note: This patch(108885-02) requires autoconfig to be run for ECC functionality to be active. Failure to run autoconfig can cause POST to fail on the CIC2 system boards.

You may also find excellent Questions and Answers at the HES Engineering Web pages. URL is:

http://hes.west/dhpg/xftt/hw_cic2.html

INTERNAL SUMMARY:

SUBMITTER: Charles Price PATCH ID: 108885-02, 108885-02, 108885-02 APPLIES TO: ATTACHMENTS:


Copyright (c) 1997-2003 Sun Microsystems, Inc.