InfoDoc ID | Synopsis | Date | ||
23571 | Compatibility for E10K System Board 501-5693 | 12 Sep 2000 |
Status | Issued |
Description |
Compatibility for E10K System Board 501-5693
E10000 system board 501-5693 requires SSP 3.3 and patch 108885-02.
The recent introduction of a new E10000 system board 501-5693 requires a specific level of SSP to take full advantage of a Revision 2 CIC ASIC. The Revision 2 CIC ASIC provides the capability of ECC for DTAG parity errors. This new functionality requires SSP 3.3 and patch
It is recommended to upgrade to SSP 3.3 and install patch 108885-02 as a preventative measure for the possibility of 501-5693 system board being installed at any point in the future. As always you should check for all recommended patches when updating the SSP level.
Please refer to patch
Note: This patch(
You may also find excellent Questions and Answers at the HES Engineering Web pages. URL is:
http://hes.west/dhpg/xftt/hw_cic2.html
INTERNAL SUMMARY:
SUBMITTER: Charles Price PATCH ID: 108885-02, 108885-02, 108885-02 APPLIES TO: ATTACHMENTS: