InfoDoc ID | Synopsis | Date | ||
23936 | How to install Sunray server in Sunray 1.1 | 18 Sep 2001 |
Status | Issued |
Description |
1. cd /cdrom/cdrom0
2. ./utinstall
This will check the OS version, apply the proper patches, and load the software.
3. /opt/SUNWut/sbin/utadm -a <interface>
This will configure the interconnect, and ask a few questions. For example:
/opt/SUNWut/sbin/utadm -a gem0 Configuring the Sun Ray Interconnect Fabric ### Configuring /etc/nsswitch.conf ### Disabling Routing ### configuring gem0 interface at subnet 128 Selected values for interface "gem0" host address: 192.168.128.1 net mask: 255.255.255.0 net address: 192.168.128.0 host name: sunray-128 net name: SunRay-128 first unit address: 192.168.128.3 last unit address: 192.168.128.254 firmware server: 192.168.128.1 Accept as is? ([Y]/N): y ### successfully setup "/etc/hostname.gem0" file ### successfully setup "/etc/inet/hosts" file ### successfully setup "/etc/netmasks" file ### successfully setup "/etc/inet/networks" file ### finished install of "gem0" interface ### Building network tables - this will take a few minutes ### Configuring DHCP Service for Sun Ray
If the default values are unacceptable, respond and enter new values. A dialog similar to the following will be displayed. In the dialog below, the network is changed from 192.168.128 to 192.168.129 and configured for a maximum of 14 sessions.
Configuring the Sun Ray Interconnect Fabric :
### configuring /etc/nsswitch.conf ### Disabling Routing ### configuring gem0 interface at subnet 128 Selected values for interface "gem0" host address: 192.168.128.1 net mask: 255.255.255.0 net address: 192.168.128.0 host name: sunray1-128 net name: SunRay-128 first unit address: 192.168.128.3 last unit address: 192.168.128.254 firmware server: 192.168.128.1 Accept as is? ([Y]/N): n new host address: [192.168.128.1] 192.168.129.1 new netmask: [255.255.255.0] new first Sun Ray address: [192.168.129.3] new last Sun Ray address: [192.168.129.254] 192.168.129.16 Selected values for interface "gem0" host address: 192.168.129.1 net mask: 255.255.255.0 net address: 192.168.129.0 host name: sunray1-129 net name: SunRay-129 first unit address: 192.168.129.3 last unit address: 192.168.129.16 firmware server: 192.168.129.1 Accept as is? ([Y]/N): y ### successfully setup "/etc/hostname.gem0" file hostname "sunray1-129" appears in "/etc/inet/hosts" file with another I
4. Reboot the server and power cycle the appliances.
5. Configure SunDS and Sun Web Server :
/opt/SUNWut/sbin/utconfig
6. Setting System Parameters
Because there are many sessions on one server, the maximum number of processes per user (maxuprc) and number of terminals (pt_cnt) need to be increased from the default Solaris levels. Set the pt_cnt value to the maximum number of users multiplied by the average number of terminal windows per user (for example, software developers use 8-10 terminal windows). When you run the utadm command to configure the interconnect fabric, a message tells you to increase these numbers if they are low.
To Set System Parameters :
1. In /etc/system, as root, use a text editor to set these parameters. For example:
set maxuprc=50 set pt_cnt=99
2. Reboot the system
ok boot -r
INTERNAL SUMMARY:
SUBMITTER: Shirin Kasad APPLIES TO: AFO Vertical Team Docs/NetAdmin ATTACHMENTS: