Front LEDs
-
System Power LED: lights green when the system is powered on
-
Each disk drive slot has a two color LED above the disk drive. The LED:
-
Remains unlit when no drive is in the slot.
-
Lights green when the drive is present but not active.
-
Flashes green when the drive in the slot is active
Rear LEDs
-
Power Supply Status, one two color LED on each power module:
-
Lights green when the power supply is operating properly.
-
Lights amber when the power supply has failed but the other power supply is operating normally, or when the power cord is unplugged.
-
Off if both power supplies are not plugged in or have failed.
-
Cooling Status, 2 two color LEDs on each cooling canister (one for each blower):
-
Lights green when the individual blower is operating properly.
-
Lights amber when the individual blower has failed.
-
Off when the cooling canister is not inserted.
-
Controller Interface Board, 2 single color LEDs:
-
Temperature Fault LED:
-
Lights amber when the board has detected a thermal fault.
-
Off when the temperature is normal.
-
Power LED:
-
Lights green when the controller interface board is powered on.
-
Off when the controller interface board is receiving no power.
Additional Keywords: blinking blink blinks yellow flash flashing
INTERNAL SUMMARY:
For a visual aid to understanding D1000 LEDs , go to the Sun System Handbook
SUBMITTER: Bill Shearer
APPLIES TO: Hardware, Hardware/Disk Storage Subsystem, Hardware/Disk Storage Subsystem/StorEdge Disk Array, Hardware/Disk Storage Subsystem/StorEdge Disk Array/StorEdge D1000
ATTACHMENTS:
Copyright (c) 1997-2003 Sun Microsystems, Inc.