InfoDoc ID | Synopsis | Date | ||
24715 | T3-Setting the Date, Time and Time Zone | 21 Aug 2001 |
Status | Issued |
Description |
The time zone and date accuracy is essential for proper T3 administration. The date and time zone will affect the scheduling daemon, and since data logging on the unit is done at local time, an incorrect date/time will confuse any effort to time-line a problem.
From the T3 master, run the tzset command to set the time zone
T300-Master:/:<1> tzset GMT-0700
From the T3 master, run the date command to set up the current date.
usage: date [yyyymmddhhmm[.ss]]
T300-Master:/:<2> date 200011151143
(GMT-0700 is MST. The tzset time zone should always match the time zone on the management host)
Run the date command to verify that the date and time are current and correct.
T300-Master:/:<3> date
Sun Nov 15:11:43 2000
INTERNAL SUMMARY:
mike.monahan@central
SUBMITTER: Mike Monahan APPLIES TO: AFO Vertical Team Docs/Storage, Hardware/Disk Storage Subsystem/StorEdge Disk Array/StorEdge T3 ATTACHMENTS: