InfoDoc ID   Synopsis   Date
25442   Recovering from a lost password on the T3   30 Jan 2001

Status Issued

Description

The following procedure shows how to identify a T3's existing password if a customer forgets the password.

1. Stop all I/O going to the T3(s).

2. Connect a console cable from the master unit to a video terminal and power off all units (both trays in a partner group).

3. Power up the master unit (leave alternate master off) and interrupt the boot process by hitting RETURN when you see the following message:

"hit the RETURN key within X seconds to cancel..."

NOTE: If you leave the alternate master on, the T3 Operating System (OS) will continue to boot. Eventually, the OS will assume there is a problem with the master (that we interrupted), disable it, and make itself the master.

4. At the "T300-EP" prompt, use the 'set passwd' command to view (and memorize...) the password.

5. Type 'reset' to reboot, and immediately power on the alternate master (if present).

6. If you choose, you can change the password after it boots with the 'passwd' command.

INTERNAL SUMMARY:

Source material provided by jason.jasner@west.sun.com

http://hes.west/nws/products/T3/faq.html

SUBMITTER: George Bolduc APPLIES TO: AFO Vertical Team Docs/Storage, Hardware/Disk Storage Subsystem/StorEdge Disk Array/StorEdge T3 ATTACHMENTS: