InfoDoc ID |
|
Synopsis |
|
Date |
26637 |
|
Dynamic Reconfiguration: Directions for the Sun Fire[TM] V880 Server |
|
10 Jul 2002 |
This document provides directions for using Dynamic Reconfiguration (DR) cfgadmin on the Sun Fire[TM] V880 Server. Directions are for the V880 server using the software command vs. using the pci DR button on the pci slots.
This example will begin by inserting a pci card in slot#6
RUN CFGADM TO VIEW THE PCI SLOTS CURRENT CONFIGURATION
------------------------------------------------------
# cfgadm
Ap_Id Type Receptacle Occupant Condition
SBa cpu/mem connected configured ok
SBb none empty unconfigured ok
SBc none empty unconfigured ok
SBd none empty unconfigured ok
c0 scsi-bus connected configured unknown
pcisch0:hpc1_slot0 unknown empty unconfigured unknown
pcisch0:hpc1_slot1 unknown empty unconfigured unknown
pcisch0:hpc1_slot2 unknown empty unconfigured unknown
pcisch0:hpc1_slot3 unknown empty unconfigured unknown
pcisch2:hpc2_slot4 unknown empty unconfigured unknown
pcisch2:hpc2_slot5 unknown empty unconfigured unknown
pcisch2:hpc2_slot6 unknown disconnected unconfigured unknown
pcisch3:hpc0_slot7 unknown empty unconfigured unknown
pcisch3:hpc0_slot8 unknown empty unconfigured unknown
#
RUN THE CONNECT COMMAND TO CONNECT THE CARD
-------------------------------------------
# cfgadm -c connect pcisch2:hpc0_slot6
#
RUN CFGADM AGAIN TO VERIFY THE CONNECTION
-----------------------------------------
# cfgadm
Ap_Id Type Receptacle Occupant Condition
#cfgadm
SBa cpu/mem connected configured ok
SBb none empty unconfigured ok
SBc none empty unconfigured ok
SBd none empty unconfigured ok
c0 scsi-bus connected configured unknown
pcisch0:hpc1_slot0 unknown empty unconfigured unknown
pcisch0:hpc1_slot1 unknown empty unconfigured unknown
pcisch0:hpc1_slot2 unknown empty unconfigured unknown
pcisch0:hpc1_slot3 unknown empty unconfigured unknown
pcisch2:hpc2_slot4 unknown empty unconfigured unknown
pcisch2:hpc2_slot5 unknown empty unconfigured unknown
pcisch2:hpc2_slot6 unknown connected unconfigured unknown
pcisch3:hpc0_slot7 unknown empty unconfigured unknown
pcisch3:hpc0_slot8 unknown empty unconfigured unknown
#
RUN CONFIGURE COMMAND TO CONFIGURE THE CARD
-------------------------------------------
# cfgadm -c configure pcisch2:hpc2_slot6
#
RUN CFGADM AGAIN TO VERIFY THE CONFIGURATION
--------------------------------------------
# cfgadm -c configure pcisch2:hpc2_slot6
# cfgadm
Ap_Id Type Receptacle Occupant Condition
SBa cpu/mem connected configured ok
SBb none empty unconfigured ok
SBc none empty unconfigured ok
SBd none empty unconfigured ok
c0 scsi-bus connected configured unknown
pcisch0:hpc1_slot0 unknown empty unconfigured unknown
pcisch0:hpc1_slot1 unknown empty unconfigured unknown
pcisch0:hpc1_slot2 unknown empty unconfigured unknown
pcisch0:hpc1_slot3 unknown empty unconfigured unknown
pcisch2:hpc2_slot4 unknown empty unconfigured unknown
pcisch2:hpc2_slot5 unknown empty unconfigured unknown
pcisch2:hpc2_slot6 bridge/hp connected configured ok
pcisch3:hpc0_slot7 unknown empty unconfigured unknown
pcisch3:hpc0_slot8 unknown empty unconfigured unknown
#
Keywords: DR, V880, cfgadm
INTERNAL SUMMARY:
SUBMITTER: Dan Auga
APPLIES TO: Hardware
ATTACHMENTS:
Copyright (c) 1997-2003 Sun Microsystems, Inc.