InfoDoc ID   Synopsis   Date
26637   Dynamic Reconfiguration: Directions for the Sun Fire[TM] V880 Server   10 Jul 2002

Status Issued

Description

This document provides directions for using Dynamic Reconfiguration (DR) cfgadmin on the Sun Fire[TM] V880 Server. Directions are for the V880 server using the software command vs. using the pci DR button on the pci slots.

This example will begin by inserting a pci card in slot#6                                                            
RUN CFGADM TO VIEW THE PCI SLOTS CURRENT CONFIGURATION
------------------------------------------------------
# cfgadm
Ap_Id                          Type         Receptacle   Occupant     Condition
SBa                            cpu/mem      connected    configured   ok
SBb                            none         empty        unconfigured ok
SBc                            none         empty        unconfigured ok
SBd                            none         empty        unconfigured ok
c0                             scsi-bus     connected    configured   unknown
pcisch0:hpc1_slot0             unknown      empty        unconfigured unknown
pcisch0:hpc1_slot1             unknown      empty        unconfigured unknown
pcisch0:hpc1_slot2             unknown      empty        unconfigured unknown
pcisch0:hpc1_slot3             unknown      empty        unconfigured unknown
pcisch2:hpc2_slot4             unknown      empty        unconfigured unknown
pcisch2:hpc2_slot5             unknown      empty        unconfigured unknown
pcisch2:hpc2_slot6             unknown      disconnected unconfigured unknown
pcisch3:hpc0_slot7             unknown      empty        unconfigured unknown
pcisch3:hpc0_slot8             unknown      empty        unconfigured unknown
#


RUN THE CONNECT COMMAND TO CONNECT THE CARD
-------------------------------------------
# cfgadm -c connect pcisch2:hpc0_slot6
# 


RUN CFGADM AGAIN TO VERIFY THE CONNECTION
-----------------------------------------
# cfgadm
Ap_Id                          Type         Receptacle   Occupant     Condition
#cfgadm
SBa                            cpu/mem      connected    configured   ok
SBb                            none         empty        unconfigured ok
SBc                            none         empty        unconfigured ok
SBd                            none         empty        unconfigured ok
c0                             scsi-bus     connected    configured   unknown
pcisch0:hpc1_slot0             unknown      empty        unconfigured unknown
pcisch0:hpc1_slot1             unknown      empty        unconfigured unknown
pcisch0:hpc1_slot2             unknown      empty        unconfigured unknown
pcisch0:hpc1_slot3             unknown      empty        unconfigured unknown
pcisch2:hpc2_slot4             unknown      empty        unconfigured unknown
pcisch2:hpc2_slot5             unknown      empty        unconfigured unknown
pcisch2:hpc2_slot6             unknown      connected    unconfigured unknown
pcisch3:hpc0_slot7             unknown      empty        unconfigured unknown
pcisch3:hpc0_slot8             unknown      empty        unconfigured unknown
# 


RUN CONFIGURE COMMAND TO CONFIGURE THE CARD
-------------------------------------------
# cfgadm -c configure pcisch2:hpc2_slot6
#


RUN CFGADM AGAIN TO VERIFY THE CONFIGURATION
--------------------------------------------
# cfgadm -c configure pcisch2:hpc2_slot6
# cfgadm
Ap_Id                          Type         Receptacle   Occupant     Condition
SBa                            cpu/mem      connected    configured   ok
SBb                            none         empty        unconfigured ok
SBc                            none         empty        unconfigured ok
SBd                            none         empty        unconfigured ok
c0                             scsi-bus     connected    configured   unknown
pcisch0:hpc1_slot0             unknown      empty        unconfigured unknown
pcisch0:hpc1_slot1             unknown      empty        unconfigured unknown
pcisch0:hpc1_slot2             unknown      empty        unconfigured unknown
pcisch0:hpc1_slot3             unknown      empty        unconfigured unknown
pcisch2:hpc2_slot4             unknown      empty        unconfigured unknown
pcisch2:hpc2_slot5             unknown      empty        unconfigured unknown
pcisch2:hpc2_slot6             bridge/hp    connected    configured   ok
pcisch3:hpc0_slot7             unknown      empty        unconfigured unknown
pcisch3:hpc0_slot8             unknown      empty        unconfigured unknown
# 

Keywords: DR, V880, cfgadm                                                          
INTERNAL SUMMARY:

SUBMITTER: Dan Auga APPLIES TO: Hardware ATTACHMENTS:


Copyright (c) 1997-2003 Sun Microsystems, Inc.