InfoDoc ID | Synopsis | Date | ||
26929 | Correct power down, power up order of RSM 2000's and A3X00's | 26 Jun 2001 |
Status | Issued |
Description |
The A3X00's and RSM 2000's need to be powered down and powered up in a specific order as not to cause a channel failure or loss of configuration.
It is imperative that whenever the need arises to power cycle an entire array, the following steps are followed.
If the RDAC module is powered on before the disks are spun up, you run the risk of the disks reporting themselves with a 'Replaced' status.
INTERNAL SUMMARY:SUBMITTER: David Graham APPLIES TO: Hardware/Disk Storage Subsystem/StorEdge Disk Array/StorEdge A3000, Hardware/Disk Storage Subsystem/StorEdge Disk Array/StorEdge A3500, Storage/RAID Manager ATTACHMENTS: