InfoDoc ID |
|
Synopsis |
|
Date |
27428 |
|
Sun Fire (3800-6800) System Controller Application (ScApp) How To's |
|
14 Aug 2001 |
Commands used from the System Controller Application (ScApp) and their outputs
=============================================================================
- How to access to the ScApp shell ?
- How to access to a Domain Console ?
- How to get and quit the 'expert' mode ?
- How to quit the 'expert' mode ?
- How to use commands ?
- How to get help ?
- How to get the SCapp version and SC uptime ?
- How to get Processor Module info ?
- How to get firmware version info ?
- How to get the MAC address of the platform ?
- How to get the image of all boards installed on your platform ?
- How to get the image of all domains configured on your platform ?
- How to get the partition configuration ?
- How to get the memory configuration on all domains configured ?
- How to get info of your boards environment (temperature, voltage, current) ?
- How to list the connections on the SC ?
- How to access to the ScApp shell via telnet ?
-----------------------------------------------
Once the SC is booted, telnet to the SC.
s12sca is the hostname of the System Controller on a Sun Fire 4800 server
tempete:lboschet> telnet s12sca
Trying 129.157.218.173...
Connected to s12sca.
Escape character is '^]'.
System Controller 's12sca':
Type 0 for Platform Shell
Type 1 for domain A console
Type 2 for domain B console
Type 3 for domain C console
Type 4 for domain D console
Input: 0
Platform Shell
s12sca:SC>
- How to access to a Domain Console ?
-------------------------------------
console domain_name
s12sca:SC> console a
Connected to Domain A
s12d1 console login:
disconnect from the domain console:
s12d1 console login: <=== CTRL + ] if connected by network
telnet> send brk or ~. if connected by serial line.
Domain Shell for Domain A - s12d1
s12sca:A> disconnect
Connection closed.
s12sca:SC>
- How to get to the 'expert' mode ?
--------------------------------
You must contact CTE for instructions to enter expert mode.
- How to use commands ?
-----------------------
All commands can be abbreviated if there are not ambiguous with another one.
Example:
s12sca:SC> showboards -- Command
s12sca:SC> showb -- Abbreviated command
If command is ambiguous you'll get the following message:
s12sca:SC> show
show: Command is ambiguous, type "help" for a list of commands.
s12sca:SC>
Some of the commands can be used only in expert mode, example below:
s12sca:SC> i2c
i2c: Command not found, type "help" for a list of commands.
s12sca:SC>
- How to get help ?
-------------------
s12sca:SC> help -- Display the commands
s12sca:SC> ? -- Display the commands
s12sca:SC> help [command] -- Displays the help of a specific command
- How to get the SCapp version and SC uptime ?
----------------------------------------------
showsc
s12sca:SC> showsc
SC: SSC0
SC date: Fri Mar 23 17:29:28 GMT+01:00 2001
SC uptime: 1 hour 45 minutes 40 seconds
ScApp version: 5.11.4
RTOS version: 17
s12sca:SC>
- How to get Processor Module info ?
------------------------------------
showboards
s12sca:SC> showboards -p cpu
CPUs
----
/partition0/domain0/SB0/bbcGroup1/cpuCD/cpusafariagent0:
part_no=0x919c version=5 manufacturer=0x07d
devid=0x1040ffe1848 (lot=0x040ffe bin=1 wafer=6 col=2 row=8)
speed=750
e$ (8MB):
J6400: 4MB, part# 370-4125-01-35, serial# 0911U7
J6300: 4MB, part# 370-4125-01-35, serial# 0911VB
DRAM DIMM Group 0 (1024MB):
J15300: 256MB, part# 501-5401-06-01, serial# 402382
J15400: 256MB, part# 501-5401-06-01, serial# 402381
J15500: 256MB, part# 501-5401-06-01, serial# 402380
J15600: 256MB, part# 501-5401-06-01, serial# 402379
DRAM DIMM Group 1 (Empty):
/partition0/domain0/SB0/bbcGroup1/cpuCD/cpusafariagent1:
part_no=0x919c version=5 manufacturer=0x07d
devid=0x103ed26350a (lot=0x03ed26 bin=1 wafer=13 col=8 row=10)
speed=750
e$ (8MB):
J7400: 4MB, part# 370-4125-01-35, serial# 09124X
J7300: 4MB, part# 370-4125-01-35, serial# 0911ZW
DRAM DIMM Group 0 (1024MB):
J16300: 256MB, part# 501-5401-06-01, serial# 402378
J16400: 256MB, part# 501-5401-06-01, serial# 402377
J16500: 256MB, part# 501-5401-06-01, serial# 402376
J16600: 256MB, part# 501-5401-06-01, serial# 402375
DRAM DIMM Group 1 (Empty):
/partition0/domain0/SB2/bbcGroup1/cpuCD/cpusafariagent0:
part_no=0x919c version=5 manufacturer=0x07d
devid=0x103ed260869 (lot=0x03ed26 bin=1 wafer=2 col=3 row=9)
speed=750
e$ (8MB):
J6400: 4MB, part# 370-4125-01-35, serial# 0911HV
J6300: 4MB, part# 370-4125-01-35, serial# 0911DY
DRAM DIMM Group 0 (1024MB):
J15300: 256MB, part# 501-5401-06-01, serial# 402101
J15400: 256MB, part# 501-5401-06-01, serial# 402107
J15500: 256MB, part# 501-5401-06-01, serial# 402106
J15600: 256MB, part# 501-5401-06-01, serial# 402105
DRAM DIMM Group 1 (Empty):
/partition0/domain0/SB2/bbcGroup1/cpuCD/cpusafariagent1:
part_no=0x919c version=5 manufacturer=0x07d
devid=0x103ed261863 (lot=0x03ed26 bin=1 wafer=6 col=3 row=3)
speed=750
e$ (8MB):
J7400: 4MB, part# 370-4125-01-35, serial# 0911NK
J7300: 4MB, part# 370-4125-01-35, serial# 0911M8
DRAM DIMM Group 0 (1024MB):
J16300: 256MB, part# 501-5401-06-01, serial# 402104
J16400: 256MB, part# 501-5401-06-01, serial# 402103
J16500: 256MB, part# 501-5401-06-01, serial# 402102
J16600: 256MB, part# 501-5401-06-01, serial# 402047
DRAM DIMM Group 1 (Empty):
s12sca:SC>
- How to get firmware version info ?
------------------------------------
showboards
s12sca:SC> showboards -p proms
Proms
-----
/SSC0/javaosflash:
ScApp 5.11.4 03/13/2001 16:54
Info 5.11.4 03/13/2001 16:54
/IB8/bbcGroup0/sysbdflash:
iPOST 5.11.4 03/13/2001 16:49
Info 5.11.4 03/13/2001 16:50
/partition0/domain0/IB6/bbcGroup0/sysbdflash:
iPOST 5.11.4 03/13/2001 16:49
Info 5.11.4 03/13/2001 16:50
/partition0/domain0/SB0/bbcGroup0/sysbdflash:
POST 5.11.4 03/13/2001 16:49
OBP 5.11.4 03/13/2001 16:49
Info 5.11.4 03/13/2001 16:49
/partition0/domain0/SB0/bbcGroup1/sysbdflash:
POST 5.11.4 03/13/2001 16:49
OBP 5.11.4 03/13/2001 16:49
Info 5.11.4 03/13/2001 16:49
/partition0/domain0/SB2/bbcGroup0/sysbdflash:
POST 5.11.4 03/13/2001 16:49
OBP 5.11.4 03/13/2001 16:49
Info 5.11.4 03/13/2001 16:49
/partition0/domain0/SB2/bbcGroup1/sysbdflash:
POST 5.11.4 03/13/2001 16:49
OBP 5.11.4 03/13/2001 16:49
Info 5.11.4 03/13/2001 16:49
s12sca:SC>
- How to get the MAC address of the platform ?
----------------------------------------------
s12sca:SC> showplatform -p mac
MAC Address HostID
----------------- --------
Domain A 08:00:20:d8:a8:f7 80d8a8f7
Domain B 08:00:20:d8:a8:f8 80d8a8f8
Domain C ff:ff:ff:ff:ff:ff ffffffff
Domain D ff:ff:ff:ff:ff:ff ffffffff
SSC0 08:00:20:d8:a8:fb 80d8a8fb
SSC1 08:00:20:d8:a8:fc 80d8a8fc
System Serial Number: 106M216D
- How to get the image of all boards installed on your platform ?
-----------------------------------------------------------------
s12sca:SC> showboards
Slot Pwr Component Type State Status Domain
---- -- ------------- ---- ----- -----
/N0/SB0 On CPU Board Active Passed A
/N0/SB2 On CPU Board Active Passed A
/N0/IB6 On PCI I/O Board Active Passed A
IB8 On PCI I/O Board Available Not tested Isolated
s12sca:SC>
- How to get the image of all domains configured on your platform ?
-------------------------------------------------------------------
showplatform
s12sca:SC> showp
Domain Solaris Nodename Domain Status Keyswitch
-------- ------------------ ----------------------- -------------
A s12d1 Active - Solaris on
B - Powered Off off
C - Powered Off off
D - Powered Off off
The system controller is configured to be on a network.
Network settings: static
Hostname: s12sca
IP Address: 129.157.218.173
Netmask: 255.255.255.0
Gateway: 129.157.218.1
DNS Domain:
Primary DNS Server:
Secondary DNS Server:
Loghost for Platform:
Loghost for Domain A:
Loghost for Domain B:
Loghost for Domain C:
Loghost for Domain D:
SNMP Agent: disabled
Chassis Description: Serengeti Control Room
Chassis Contact: Equipe EMEA Technical Center
Chassis Location: Velizy - SaintEx 2
ACL for Domain A: SB0 SB2 SB4 IB6 IB8
ACL for Domain B: SB0 SB2 SB4 IB6 IB8
ACL for Domain C: SB0 SB2 SB4 IB6 IB8
ACL for Domain D: SB0 SB2 SB4 IB6 IB8
SC POST diag Level: quick
Chassis is in single partition mode.
s12sca:SC>
- How to get the partition configuration ?
------------------------------------------
showplatform
s12sca:SC> showplatform -p partition
Chassis is in single partition mode.
s12sca:SC>
- How to get the memory configuration on all domains configured ?
-----------------------------------------------------------------
showboards
s12sca:SC> showboards -p memory
Memory
------
Domain A: Memory = 4096MB
Domain B: Memory = 0MB
Domain C: Memory = 0MB
Domain D: Memory = 0MB
s12sca:SC>
- How to get info of your boards environment (temperature, voltage, current) ?
------------------------------------------------------------------------------
showenvironment
s12sca:SC> showenvironment
Slot Device Sensor Value Units Age Status
---- --------- --------- ------ --------- ------- ------
SSC0 SBBC 0 Temp. 0 44 Degrees C 3 sec OK
SSC0 CBH 0 Temp. 0 51 Degrees C 3 sec OK
SSC0 Board 0 Temp. 0 31 Degrees C 4 sec OK
SSC0 Board 0 Temp. 1 31 Degrees C 4 sec OK
SSC0 Board 0 Temp. 2 31 Degrees C 4 sec OK
SSC0 Board 0 1.5 VDC 0 1.50 Volts DC 4 sec OK
SSC0 Board 0 3.3 VDC 0 3.37 Volts DC 4 sec OK
SSC0 Board 0 5 VDC 0 5.01 Volts DC 4 sec OK
/N0/SB0 Board 0 1.5 VDC 0 1.50 Volts DC 1 sec OK
/N0/SB0 Board 0 3.3 VDC 0 3.33 Volts DC 1 sec OK
/N0/SB0 SDC 0 Temp. 0 69 Degrees C 1 sec OK
/N0/SB0 AR 0 Temp. 0 54 Degrees C 1 sec OK
/N0/SB0 DX 0 Temp. 0 64 Degrees C 1 sec OK
/N0/SB0 DX 1 Temp. 0 68 Degrees C 1 sec OK
/N0/SB0 DX 2 Temp. 0 65 Degrees C 1 sec OK
/N0/SB0 DX 3 Temp. 0 67 Degrees C 1 sec OK
/N0/SB0 SBBC 0 Temp. 0 56 Degrees C 1 sec OK
/N0/SB0 Board 1 Temp. 0 22 Degrees C 1 sec OK
/N0/SB0 Board 1 Temp. 1 21 Degrees C 1 sec OK
/N0/SB0 SBBC 1 Temp. 0 59 Degrees C 1 sec OK
/N0/SB0 Board 1 Temp. 2 28 Degrees C 1 sec OK
/N0/SB0 Board 1 Temp. 3 28 Degrees C 1 sec OK
/N0/SB0 Cheetah 2 Temp. 0 62 Degrees C 1 sec OK
/N0/SB0 Cheetah 2 1.8 VDC 0 1.71 Volts DC 2 sec OK
/N0/SB0 Cheetah 3 Temp. 0 56 Degrees C 2 sec OK
/N0/SB0 Cheetah 3 1.8 VDC 1 1.71 Volts DC 2 sec OK
/N0/IB6 Board 0 1.5 VDC 0 1.51 Volts DC 7 sec OK
/N0/IB6 Board 0 3.3 VDC 0 3.35 Volts DC 7 sec OK
/N0/IB6 Board 0 5 VDC 0 4.95 Volts DC 7 sec OK
/N0/IB6 Board 0 12 VDC 0 12.11 Volts DC 7 sec OK
/N0/IB6 Board 0 Temp. 0 31 Degrees C 7 sec OK
/N0/IB6 Board 0 Temp. 1 31 Degrees C 7 sec OK
/N0/IB6 SDC 0 Temp. 0 73 Degrees C 7 sec OK
/N0/IB6 AR 0 Temp. 0 45 Degrees C 7 sec OK
/N0/IB6 DX 0 Temp. 0 54 Degrees C 7 sec OK
/N0/IB6 DX 1 Temp. 0 51 Degrees C 7 sec OK
/N0/IB6 SBBC 0 Temp. 0 52 Degrees C 7 sec OK
/N0/IB6 IOASIC 0 Temp. 0 58 Degrees C 7 sec OK
/N0/IB6 IOASIC 1 Temp. 1 44 Degrees C 7 sec OK
/N0/SB2 Board 0 1.5 VDC 0 1.51 Volts DC 2 sec OK
/N0/SB2 Board 0 3.3 VDC 0 3.31 Volts DC 2 sec OK
/N0/SB2 SDC 0 Temp. 0 72 Degrees C 2 sec OK
/N0/SB2 AR 0 Temp. 0 64 Degrees C 2 sec OK
/N0/SB2 DX 0 Temp. 0 65 Degrees C 2 sec OK
/N0/SB2 DX 1 Temp. 0 66 Degrees C 2 sec OK
/N0/SB2 DX 2 Temp. 0 68 Degrees C 2 sec OK
/N0/SB2 DX 3 Temp. 0 64 Degrees C 2 sec OK
/N0/SB2 SBBC 0 Temp. 0 56 Degrees C 2 sec OK
/N0/SB2 Board 1 Temp. 0 21 Degrees C 2 sec OK
/N0/SB2 Board 1 Temp. 1 21 Degrees C 2 sec OK
/N0/SB2 SBBC 1 Temp. 0 51 Degrees C 2 sec OK
/N0/SB2 Board 1 Temp. 2 26 Degrees C 2 sec OK
/N0/SB2 Board 1 Temp. 3 26 Degrees C 2 sec OK
/N0/SB2 Cheetah 2 Temp. 0 57 Degrees C 2 sec OK
/N0/SB2 Cheetah 2 1.8 VDC 0 1.71 Volts DC 2 sec OK
/N0/SB2 Cheetah 3 Temp. 0 55 Degrees C 2 sec OK
/N0/SB2 Cheetah 3 1.8 VDC 1 1.72 Volts DC 2 sec OK
RP0 Board 0 1.5 VDC 0 1.49 Volts DC 5 sec OK
RP0 Board 0 3.3 VDC 0 3.35 Volts DC 5 sec OK
RP0 Board 0 Temp. 0 29 Degrees C 5 sec OK
RP0 Board 0 Temp. 1 29 Degrees C 5 sec OK
RP0 SDC 0 Temp. 0 65 Degrees C 6 sec OK
RP0 AR 0 Temp. 0 62 Degrees C 6 sec OK
RP0 DX 0 Temp. 0 57 Degrees C 6 sec OK
RP0 DX 1 Temp. 0 49 Degrees C 6 sec OK
RP2 Board 0 1.5 VDC 0 1.50 Volts DC 6 sec OK
RP2 Board 0 3.3 VDC 0 3.39 Volts DC 6 sec OK
RP2 Board 0 Temp. 0 29 Degrees C 6 sec OK
RP2 Board 0 Temp. 1 29 Degrees C 6 sec OK
RP2 SDC 0 Temp. 0 70 Degrees C 6 sec OK
RP2 AR 0 Temp. 0 60 Degrees C 6 sec OK
RP2 DX 0 Temp. 0 60 Degrees C 6 sec OK
RP2 DX 1 Temp. 0 53 Degrees C 6 sec OK
PS0 48 VDC 0 Current 0 5.87 Amps 1 sec OK
PS0 48 VDC 0 Temp. 0 27 Degrees C 1 sec OK
PS0 48 VDC 1 Current 0 0.20 Amps 1 sec OK
PS0 48 VDC 1 48 VDC 0 55.02 Volts DC 1 sec OK
PS0 48 VDC 0 48 VDC 0 56.07 Volts DC 1 sec OK
PS1 48 VDC 0 Current 0 0.00 Amps 8 sec OK
PS1 48 VDC 0 Temp. 0 28 Degrees C 8 sec OK
PS1 48 VDC 1 Current 0 0.74 Amps 8 sec OK
PS1 48 VDC 1 48 VDC 0 55.02 Volts DC 8 sec OK
PS1 48 VDC 0 48 VDC 0 56.33 Volts DC 8 sec OK
PS2 48 VDC 0 Current 0 5.32 Amps 8 sec OK
PS2 48 VDC 0 Temp. 0 30 Degrees C 8 sec OK
PS2 48 VDC 1 Current 0 0.22 Amps 8 sec OK
PS2 48 VDC 1 48 VDC 0 55.02 Volts DC 8 sec OK
PS2 48 VDC 0 48 VDC 0 56.33 Volts DC 8 sec OK
IB8 Board 0 1.5 VDC 0 1.51 Volts DC 3 sec OK
IB8 Board 0 3.3 VDC 0 3.35 Volts DC 3 sec OK
IB8 Board 0 5 VDC 0 4.98 Volts DC 3 sec OK
IB8 Board 0 12 VDC 0 12.11 Volts DC 3 sec OK
IB8 Board 0 Temp. 0 29 Degrees C 3 sec OK
IB8 Board 0 Temp. 1 31 Degrees C 3 sec OK
IB8 SDC 0 Temp. 0 62 Degrees C 3 sec OK
IB8 AR 0 Temp. 0 51 Degrees C 3 sec OK
IB8 DX 0 Temp. 0 58 Degrees C 3 sec OK
IB8 DX 1 Temp. 0 53 Degrees C 3 sec OK
IB8 SBBC 0 Temp. 0 56 Degrees C 3 sec OK
IB8 IOASIC 0 Temp. 0 55 Degrees C 4 sec OK
IB8 IOASIC 1 Temp. 1 49 Degrees C 4 sec OK
s12sca:SC>
- How to list the connections on the SC ?
-----------------------------------------
connections
s12sca:SC> connections
ID Hostname Idle Time Connected On Connected To
--- ------------------------ --------- -------------- --------------
1 localhost 01:46 Mar 23 15:44 Platform
4 129.157.218.24 00:14 Mar 23 17:19 Platform
6 129.157.178.163 - Mar 23 17:22 Platform
s12sca:SC>
INTERNAL SUMMARY:
Transferred from sunsolve.france, "French Documents" collection.
DOCUMENT ID : 1185
SYNOPSIS : Serengeti: System Controler Application (ScApp) How To's
SUBMITTER : lguichar@france
CREATION DATE : 16/11/00
LAST MODIFIER : lboschet@france
LAST MODIFICATION DATE : 23/03/01
SUBMITTER: George Bolduc
APPLIES TO: Hardware/Sun Fire
ATTACHMENTS:
Copyright (c) 1997-2003 Sun Microsystems, Inc.