InfoDoc ID   Synopsis   Date
27428   Sun Fire (3800-6800) System Controller Application (ScApp) How To's   14 Aug 2001

Status Issued

Description
                               
Commands used from the System Controller Application (ScApp) and their outputs
=============================================================================

- How to access to the ScApp shell ?
- How to access to a Domain Console ?
- How to get and quit the 'expert' mode ?
- How to quit the 'expert' mode ?
- How to use commands ?
- How to get help ?
- How to get the SCapp version and SC uptime ?
- How to get Processor Module info ?
- How to get firmware version info ?
- How to get the  MAC address of the platform ?
- How to get the image of all boards installed on your platform ?
- How to get the image of all domains configured on your platform ?
- How to get the partition configuration ?
- How to get the memory configuration on all domains configured ?
- How to get info of your boards environment (temperature, voltage, current) ?
- How to list the connections on the SC ?

- How to access to the ScApp shell via telnet ?
-----------------------------------------------

Once the SC is booted, telnet to the SC.

s12sca is the hostname of the System Controller on a Sun Fire 4800 server

tempete:lboschet> telnet s12sca
Trying 129.157.218.173...
Connected to s12sca.
Escape character is '^]'.


System Controller 's12sca':

    Type  0  for Platform Shell

    Type  1  for domain A console
    Type  2  for domain B console
    Type  3  for domain C console
    Type  4  for domain D console

    Input: 0

Platform Shell

s12sca:SC> 

- How to access to a Domain Console ?
-------------------------------------

console domain_name

s12sca:SC> console a

Connected to Domain A

s12d1 console login: 

disconnect from the domain console:

s12d1 console login:            <=== CTRL + ] if connected by network
telnet> send brk                     or ~. if connected by serial line.

Domain Shell for Domain A - s12d1

s12sca:A> disconnect
Connection closed.
s12sca:SC> 

- How to get to the 'expert' mode ?
--------------------------------

You must contact CTE for instructions to enter expert mode.


- How to use commands ?
-----------------------

All commands can be abbreviated if there are not ambiguous with another one.

Example:

s12sca:SC> showboards           -- Command
s12sca:SC> showb                -- Abbreviated command

If command is ambiguous you'll get the following message:

s12sca:SC> show
show: Command is ambiguous, type "help" for a list of commands.
s12sca:SC> 

Some of the commands can be used only in expert mode, example below:

s12sca:SC> i2c
i2c: Command not found, type "help" for a list of commands.
s12sca:SC> 

- How to get help ?
-------------------

s12sca:SC> help                 -- Display the commands

s12sca:SC> ?                    -- Display the commands 

s12sca:SC> help [command]       -- Displays the help of a specific command


- How to get the SCapp version and SC uptime ?
----------------------------------------------

showsc 

s12sca:SC> showsc

SC: SSC0  

SC date: Fri Mar 23 17:29:28 GMT+01:00 2001
SC uptime: 1 hour 45 minutes 40 seconds 

ScApp version: 5.11.4
RTOS version: 17

s12sca:SC> 

- How to get Processor Module info ?
------------------------------------

showboards 

s12sca:SC> showboards -p cpu

CPUs
----
/partition0/domain0/SB0/bbcGroup1/cpuCD/cpusafariagent0: 
        part_no=0x919c version=5 manufacturer=0x07d
        devid=0x1040ffe1848 (lot=0x040ffe bin=1 wafer=6 col=2 row=8)
        speed=750
        e$ (8MB):
                J6400: 4MB, part# 370-4125-01-35, serial# 0911U7
                J6300: 4MB, part# 370-4125-01-35, serial# 0911VB
        DRAM DIMM Group 0 (1024MB):
                J15300: 256MB, part# 501-5401-06-01, serial# 402382
                J15400: 256MB, part# 501-5401-06-01, serial# 402381
                J15500: 256MB, part# 501-5401-06-01, serial# 402380
                J15600: 256MB, part# 501-5401-06-01, serial# 402379
        DRAM DIMM Group 1 (Empty):
/partition0/domain0/SB0/bbcGroup1/cpuCD/cpusafariagent1: 
        part_no=0x919c version=5 manufacturer=0x07d
        devid=0x103ed26350a (lot=0x03ed26 bin=1 wafer=13 col=8 row=10)
        speed=750
        e$ (8MB):
                J7400: 4MB, part# 370-4125-01-35, serial# 09124X
                J7300: 4MB, part# 370-4125-01-35, serial# 0911ZW
        DRAM DIMM Group 0 (1024MB):
                J16300: 256MB, part# 501-5401-06-01, serial# 402378
                J16400: 256MB, part# 501-5401-06-01, serial# 402377
                J16500: 256MB, part# 501-5401-06-01, serial# 402376
                J16600: 256MB, part# 501-5401-06-01, serial# 402375
        DRAM DIMM Group 1 (Empty):
/partition0/domain0/SB2/bbcGroup1/cpuCD/cpusafariagent0: 
        part_no=0x919c version=5 manufacturer=0x07d
        devid=0x103ed260869 (lot=0x03ed26 bin=1 wafer=2 col=3 row=9)
        speed=750
        e$ (8MB):
                J6400: 4MB, part# 370-4125-01-35, serial# 0911HV
                J6300: 4MB, part# 370-4125-01-35, serial# 0911DY
        DRAM DIMM Group 0 (1024MB):
                J15300: 256MB, part# 501-5401-06-01, serial# 402101
                J15400: 256MB, part# 501-5401-06-01, serial# 402107
                J15500: 256MB, part# 501-5401-06-01, serial# 402106
                J15600: 256MB, part# 501-5401-06-01, serial# 402105
        DRAM DIMM Group 1 (Empty):
/partition0/domain0/SB2/bbcGroup1/cpuCD/cpusafariagent1: 
        part_no=0x919c version=5 manufacturer=0x07d
        devid=0x103ed261863 (lot=0x03ed26 bin=1 wafer=6 col=3 row=3)
        speed=750
        e$ (8MB):
                J7400: 4MB, part# 370-4125-01-35, serial# 0911NK
                J7300: 4MB, part# 370-4125-01-35, serial# 0911M8
        DRAM DIMM Group 0 (1024MB):
                J16300: 256MB, part# 501-5401-06-01, serial# 402104
                J16400: 256MB, part# 501-5401-06-01, serial# 402103
                J16500: 256MB, part# 501-5401-06-01, serial# 402102
                J16600: 256MB, part# 501-5401-06-01, serial# 402047
        DRAM DIMM Group 1 (Empty):
s12sca:SC> 

- How to get firmware version info ?
------------------------------------

showboards

s12sca:SC> showboards -p proms

Proms
-----
/SSC0/javaosflash: 
        ScApp  5.11.4  03/13/2001 16:54
        Info   5.11.4  03/13/2001 16:54

/IB8/bbcGroup0/sysbdflash: 
        iPOST  5.11.4  03/13/2001 16:49
        Info   5.11.4  03/13/2001 16:50

/partition0/domain0/IB6/bbcGroup0/sysbdflash: 
        iPOST  5.11.4  03/13/2001 16:49
        Info   5.11.4  03/13/2001 16:50

/partition0/domain0/SB0/bbcGroup0/sysbdflash: 
        POST   5.11.4  03/13/2001 16:49
        OBP    5.11.4  03/13/2001 16:49
        Info   5.11.4  03/13/2001 16:49

/partition0/domain0/SB0/bbcGroup1/sysbdflash: 
        POST   5.11.4  03/13/2001 16:49
        OBP    5.11.4  03/13/2001 16:49
        Info   5.11.4  03/13/2001 16:49

/partition0/domain0/SB2/bbcGroup0/sysbdflash: 
        POST   5.11.4  03/13/2001 16:49
        OBP    5.11.4  03/13/2001 16:49
        Info   5.11.4  03/13/2001 16:49

/partition0/domain0/SB2/bbcGroup1/sysbdflash: 
        POST   5.11.4  03/13/2001 16:49
        OBP    5.11.4  03/13/2001 16:49
        Info   5.11.4  03/13/2001 16:49

s12sca:SC> 

- How to get the  MAC address of the platform ?
----------------------------------------------

s12sca:SC> showplatform -p mac

              MAC Address          HostID  
              -----------------    --------
Domain A      08:00:20:d8:a8:f7    80d8a8f7
Domain B      08:00:20:d8:a8:f8    80d8a8f8
Domain C      ff:ff:ff:ff:ff:ff    ffffffff
Domain D      ff:ff:ff:ff:ff:ff    ffffffff
SSC0          08:00:20:d8:a8:fb    80d8a8fb
SSC1          08:00:20:d8:a8:fc    80d8a8fc

System Serial Number: 106M216D

- How to get the image of all boards installed on your platform ?
-----------------------------------------------------------------

s12sca:SC> showboards

Slot     Pwr Component Type                 State      Status     Domain
----     --  -------------                  ----       -----      -----
/N0/SB0  On  CPU Board                      Active     Passed     A
/N0/SB2  On  CPU Board                      Active     Passed     A
/N0/IB6  On  PCI I/O Board                  Active     Passed     A
IB8      On  PCI I/O Board                  Available  Not tested Isolated

s12sca:SC> 

- How to get the image of all domains configured on your platform ?
-------------------------------------------------------------------

showplatform

s12sca:SC> showp

Domain    Solaris Nodename    Domain Status            Keyswitch      
--------  ------------------  -----------------------  -------------  
A         s12d1               Active - Solaris         on                  
B         -                   Powered Off              off                 
C         -                   Powered Off              off                 
D         -                   Powered Off              off                 

The system controller is configured to be on a network.
Network settings: static
Hostname: s12sca
IP Address: 129.157.218.173
Netmask: 255.255.255.0
Gateway: 129.157.218.1
DNS Domain: 
Primary DNS Server: 
Secondary DNS Server: 

Loghost for Platform:  
Loghost for Domain A:  
Loghost for Domain B:  
Loghost for Domain C:  
Loghost for Domain D:  

SNMP Agent: disabled
Chassis Description: Serengeti Control Room
Chassis Contact: Equipe EMEA Technical Center
Chassis Location: Velizy - SaintEx 2

ACL for Domain A: SB0 SB2 SB4 IB6 IB8 
ACL for Domain B: SB0 SB2 SB4 IB6 IB8 
ACL for Domain C: SB0 SB2 SB4 IB6 IB8 
ACL for Domain D: SB0 SB2 SB4 IB6 IB8 

SC POST diag Level: quick

Chassis is in single partition mode.

s12sca:SC> 

- How to get the partition configuration ?
------------------------------------------

showplatform

s12sca:SC> showplatform -p partition 

Chassis is in single partition mode.

s12sca:SC> 

- How to get the memory configuration on all domains configured ?
-----------------------------------------------------------------

showboards

s12sca:SC> showboards -p memory

Memory
------
Domain A: Memory = 4096MB
Domain B: Memory = 0MB
Domain C: Memory = 0MB
Domain D: Memory = 0MB

s12sca:SC> 

- How to get info of your boards environment (temperature, voltage, current) ?
------------------------------------------------------------------------------

showenvironment

s12sca:SC> showenvironment               

Slot Device    Sensor    Value  Units     Age     Status
---- --------- --------- ------ --------- ------- ------
SSC0 SBBC 0    Temp. 0    44    Degrees C   3 sec OK
SSC0 CBH 0     Temp. 0    51    Degrees C   3 sec OK
SSC0 Board 0   Temp. 0    31    Degrees C   4 sec OK
SSC0 Board 0   Temp. 1    31    Degrees C   4 sec OK
SSC0 Board 0   Temp. 2    31    Degrees C   4 sec OK
SSC0 Board 0   1.5 VDC 0   1.50 Volts DC    4 sec OK
SSC0 Board 0   3.3 VDC 0   3.37 Volts DC    4 sec OK
SSC0 Board 0   5 VDC 0     5.01 Volts DC    4 sec OK
/N0/SB0 Board 0   1.5 VDC 0   1.50 Volts DC    1 sec OK
/N0/SB0 Board 0   3.3 VDC 0   3.33 Volts DC    1 sec OK
/N0/SB0 SDC 0     Temp. 0    69    Degrees C   1 sec OK
/N0/SB0 AR 0      Temp. 0    54    Degrees C   1 sec OK
/N0/SB0 DX 0      Temp. 0    64    Degrees C   1 sec OK
/N0/SB0 DX 1      Temp. 0    68    Degrees C   1 sec OK
/N0/SB0 DX 2      Temp. 0    65    Degrees C   1 sec OK
/N0/SB0 DX 3      Temp. 0    67    Degrees C   1 sec OK
/N0/SB0 SBBC 0    Temp. 0    56    Degrees C   1 sec OK
/N0/SB0 Board 1   Temp. 0    22    Degrees C   1 sec OK
/N0/SB0 Board 1   Temp. 1    21    Degrees C   1 sec OK
/N0/SB0 SBBC 1    Temp. 0    59    Degrees C   1 sec OK
/N0/SB0 Board 1   Temp. 2    28    Degrees C   1 sec OK
/N0/SB0 Board 1   Temp. 3    28    Degrees C   1 sec OK
/N0/SB0 Cheetah 2 Temp. 0    62    Degrees C   1 sec OK
/N0/SB0 Cheetah 2 1.8 VDC 0   1.71 Volts DC    2 sec OK
/N0/SB0 Cheetah 3 Temp. 0    56    Degrees C   2 sec OK
/N0/SB0 Cheetah 3 1.8 VDC 1   1.71 Volts DC    2 sec OK
/N0/IB6 Board 0   1.5 VDC 0   1.51 Volts DC    7 sec OK
/N0/IB6 Board 0   3.3 VDC 0   3.35 Volts DC    7 sec OK
/N0/IB6 Board 0   5 VDC 0     4.95 Volts DC    7 sec OK
/N0/IB6 Board 0   12 VDC 0   12.11 Volts DC    7 sec OK
/N0/IB6 Board 0   Temp. 0    31    Degrees C   7 sec OK
/N0/IB6 Board 0   Temp. 1    31    Degrees C   7 sec OK
/N0/IB6 SDC 0     Temp. 0    73    Degrees C   7 sec OK
/N0/IB6 AR 0      Temp. 0    45    Degrees C   7 sec OK
/N0/IB6 DX 0      Temp. 0    54    Degrees C   7 sec OK
/N0/IB6 DX 1      Temp. 0    51    Degrees C   7 sec OK
/N0/IB6 SBBC 0    Temp. 0    52    Degrees C   7 sec OK
/N0/IB6 IOASIC 0  Temp. 0    58    Degrees C   7 sec OK
/N0/IB6 IOASIC 1  Temp. 1    44    Degrees C   7 sec OK
/N0/SB2 Board 0   1.5 VDC 0   1.51 Volts DC    2 sec OK
/N0/SB2 Board 0   3.3 VDC 0   3.31 Volts DC    2 sec OK
/N0/SB2 SDC 0     Temp. 0    72    Degrees C   2 sec OK
/N0/SB2 AR 0      Temp. 0    64    Degrees C   2 sec OK
/N0/SB2 DX 0      Temp. 0    65    Degrees C   2 sec OK
/N0/SB2 DX 1      Temp. 0    66    Degrees C   2 sec OK
/N0/SB2 DX 2      Temp. 0    68    Degrees C   2 sec OK
/N0/SB2 DX 3      Temp. 0    64    Degrees C   2 sec OK
/N0/SB2 SBBC 0    Temp. 0    56    Degrees C   2 sec OK
/N0/SB2 Board 1   Temp. 0    21    Degrees C   2 sec OK
/N0/SB2 Board 1   Temp. 1    21    Degrees C   2 sec OK
/N0/SB2 SBBC 1    Temp. 0    51    Degrees C   2 sec OK
/N0/SB2 Board 1   Temp. 2    26    Degrees C   2 sec OK
/N0/SB2 Board 1   Temp. 3    26    Degrees C   2 sec OK
/N0/SB2 Cheetah 2 Temp. 0    57    Degrees C   2 sec OK
/N0/SB2 Cheetah 2 1.8 VDC 0   1.71 Volts DC    2 sec OK
/N0/SB2 Cheetah 3 Temp. 0    55    Degrees C   2 sec OK
/N0/SB2 Cheetah 3 1.8 VDC 1   1.72 Volts DC    2 sec OK
RP0  Board 0   1.5 VDC 0   1.49 Volts DC    5 sec OK
RP0  Board 0   3.3 VDC 0   3.35 Volts DC    5 sec OK
RP0  Board 0   Temp. 0    29    Degrees C   5 sec OK
RP0  Board 0   Temp. 1    29    Degrees C   5 sec OK
RP0  SDC 0     Temp. 0    65    Degrees C   6 sec OK
RP0  AR 0      Temp. 0    62    Degrees C   6 sec OK
RP0  DX 0      Temp. 0    57    Degrees C   6 sec OK
RP0  DX 1      Temp. 0    49    Degrees C   6 sec OK
RP2  Board 0   1.5 VDC 0   1.50 Volts DC    6 sec OK
RP2  Board 0   3.3 VDC 0   3.39 Volts DC    6 sec OK
RP2  Board 0   Temp. 0    29    Degrees C   6 sec OK
RP2  Board 0   Temp. 1    29    Degrees C   6 sec OK
RP2  SDC 0     Temp. 0    70    Degrees C   6 sec OK
RP2  AR 0      Temp. 0    60    Degrees C   6 sec OK
RP2  DX 0      Temp. 0    60    Degrees C   6 sec OK
RP2  DX 1      Temp. 0    53    Degrees C   6 sec OK
PS0  48 VDC 0  Current 0   5.87 Amps        1 sec OK
PS0  48 VDC 0  Temp. 0    27    Degrees C   1 sec OK
PS0  48 VDC 1  Current 0   0.20 Amps        1 sec OK
PS0  48 VDC 1  48 VDC 0   55.02 Volts DC    1 sec OK
PS0  48 VDC 0  48 VDC 0   56.07 Volts DC    1 sec OK
PS1  48 VDC 0  Current 0   0.00 Amps        8 sec OK
PS1  48 VDC 0  Temp. 0    28    Degrees C   8 sec OK
PS1  48 VDC 1  Current 0   0.74 Amps        8 sec OK
PS1  48 VDC 1  48 VDC 0   55.02 Volts DC    8 sec OK
PS1  48 VDC 0  48 VDC 0   56.33 Volts DC    8 sec OK
PS2  48 VDC 0  Current 0   5.32 Amps        8 sec OK
PS2  48 VDC 0  Temp. 0    30    Degrees C   8 sec OK
PS2  48 VDC 1  Current 0   0.22 Amps        8 sec OK
PS2  48 VDC 1  48 VDC 0   55.02 Volts DC    8 sec OK
PS2  48 VDC 0  48 VDC 0   56.33 Volts DC    8 sec OK
IB8  Board 0   1.5 VDC 0   1.51 Volts DC    3 sec OK
IB8  Board 0   3.3 VDC 0   3.35 Volts DC    3 sec OK
IB8  Board 0   5 VDC 0     4.98 Volts DC    3 sec OK
IB8  Board 0   12 VDC 0   12.11 Volts DC    3 sec OK
IB8  Board 0   Temp. 0    29    Degrees C   3 sec OK
IB8  Board 0   Temp. 1    31    Degrees C   3 sec OK
IB8  SDC 0     Temp. 0    62    Degrees C   3 sec OK
IB8  AR 0      Temp. 0    51    Degrees C   3 sec OK
IB8  DX 0      Temp. 0    58    Degrees C   3 sec OK
IB8  DX 1      Temp. 0    53    Degrees C   3 sec OK
IB8  SBBC 0    Temp. 0    56    Degrees C   3 sec OK
IB8  IOASIC 0  Temp. 0    55    Degrees C   4 sec OK
IB8  IOASIC 1  Temp. 1    49    Degrees C   4 sec OK
s12sca:SC> 

- How to list the connections on the SC ?
-----------------------------------------

connections

s12sca:SC> connections

ID  Hostname                 Idle Time Connected On   Connected To   
--- ------------------------ --------- -------------- -------------- 
  1 localhost                01:46     Mar 23 15:44   Platform       
  4 129.157.218.24           00:14     Mar 23 17:19   Platform       
  6 129.157.178.163          -         Mar 23 17:22   Platform       

s12sca:SC> 

            
INTERNAL SUMMARY:
Transferred from sunsolve.france, "French Documents" collection.

DOCUMENT ID : 1185
SYNOPSIS : Serengeti: System Controler Application (ScApp) How To's
SUBMITTER : lguichar@france
CREATION DATE : 16/11/00
LAST MODIFIER : lboschet@france
LAST MODIFICATION DATE : 23/03/01            
SUBMITTER: George Bolduc APPLIES TO: Hardware/Sun Fire ATTACHMENTS:


Copyright (c) 1997-2003 Sun Microsystems, Inc.