InfoDoc ID   Synopsis   Date
28145   SNMP Module Installation on SunRay 1.3   4 Sep 2001

Status Issued

Description

The SunRay server software (SRSS) 1.3 provides SNMP support via Sun Management Center. (SunMC).

On SunMC Server:

Install the package SUNWutesa to get localized properties.

	# cd <CDimage>/Sun_Ray_Ent_Server_1.3/Solaris_2.6+/Product
	# pkgadd -d . SUNWutesa      

On SunRay Server:

If SunMC master agent is already installed, just install the SRSS 1.3 Software.

If SunMC master agent is not installed, run the utsunmc script.

SunMC should be installed before SRSS 1.3, during which time the link between SunRay and SunMC is properly established. If however SRSS 1.3 is installed first, you must run the following script:

/opt/SUNWut/sbin/utsunmc

INTERNAL SUMMARY:

Name: Chandu Krishnagiri

Email: Krishnagiri.Chandrasekhar@sun.com

SUBMITTER: Chandu Krishnagiri APPLIES TO: AFO Vertical Team Docs/NetAdmin, AFO Vertical Team Docs/Network1 ATTACHMENTS:


Copyright (c) 1997-2003 Sun Microsystems, Inc.