InfoDoc ID | Synopsis | Date | ||
42543 | E250 Enviromental Information | 13 Feb 2002 |
Status | Issued |
Description |
On an E250 there are 6 sensors located around the machine. They are labeled as follows:
CPU0 CPU1 MB0 MB1 PDB SCSI CPU0 AND CPU1 are for the cpu's MB0 AND MB1 are for the system board PDB is for the power distribution board SCSI is for the disk scsi backplane
In a typical "prtdiag -v" they would be viewed as such
============= Environmental Status ============
System Temperatures (Celsius):
------------------------------
CPU0 46
CPU1 44
MB0 38
MB1 36
PDB 35
SCSI 30
=================================
The warning and the critical temperature thresholds have changed from what is in the Sun Enterprise 250 Server Owner's Guide.
The new thresholds are as follows:
Ambient temperature inside the machine Warning 55 degrees C Critical 60 degrees C
Cpu module temperatures are now
Warning 63 degrees C Critical 68 degrees C
The E250 also issues a warning if the temperature reaches a low threshold.
The low temperature thresholds are as follows
Ambient 5 degrees C CPU 0 degrees C
There is no automatic shutdown when there is a low temperature condition.