43208 | StorEdge[TM] 9900 WWN to port location. | 27 Feb 2002 |
Status | Issued |
Description |
How to identify the physical port of an StorEdge[TM] 9900 from the World Wide Number as for example in the following messages.
Jan 14 15:10:09 hostname jnic: [ID 714618 kern.notice] jnic1: Port 0211EF (WWN 500060E802C67600:500060E802C67600) available.
Jan 14 15:10:09 hostname jnic: [ID 713730 kern.notice] jnic1: Port 0214E8 (WWN 500060E802C67601:500060E802C67601) available.
Jan 14 15:10:10 hostname jnic: [ID 984565 kern.notice] jnic1: Port 0411EF (WWN 500060E802C4EF00:500060E802C4EF00) available.
Jan 14 15:10:10 hostname jnic: [ID 983677 kern.notice] jnic1: Port 0414E8 (WWN 500060E802C4EF01:500060E802C4EF01) available.
500060E8WWXXXXYZ 500060E8 HDS assigned WWN WW = 01 7700 02 9900 (always 02 for Sun StorEdge[TM] 9900) XXXX = Serial number of box expressed in hexadecimal Y = 0 Cluster 1 (Left hand side) 1 Cluster 2 (Right hand side) Z = 0 Port A = 1 Port B = 2 Port C = 3 Port D = 4 Port E = 5 Port F = 6 Port G = 7 Port H = 8 Port J (Note there is no Port I) = 9 Port K = A Port L = B Port M = C Port N = D Port O = E Port P = F Port Q example: WWN 500060E802C67601 500060E802 HDS assigned number + model (constant for Sun StorEdge[TM] 9900) C676 = 50806(decimal) 0 = Cluster 1 (Left Hand Side) 1 = Port B
INTERNAL SUMMARY:
SUBMITTER: George Bolduc APPLIES TO: Hardware/Disk Storage Subsystem/StorEdge Disk Array/StorEdge 9900 ATTACHMENTS: