InfoDoc ID | Synopsis | Date | ||
43212 | CPRE-NWS A5x00, T3/T3+, E3500 & SSA FCAL Disk Firmware/Patch Matrix Summary Rev. 3.15 | 22 Jan 2003 |
Status | Issued |
Description |
Date: January 23, 2003
(Formerly Early Notifier 14838)
Basic Patch Function(s) | ||
Solaris | Basic Patch function(s) | Patch |
---|---|---|
2.5.1 | OBP & SOC+ Fcode | 103346-xx (c) |
SSD | 104708-21 (b) | |
IB, Socal, sf & Luxadm | 105310-14 (b) | |
SES | 105324-04 (b) | |
FC100/s Fcode (Sbus) | 109400-03 (c) | |
Disc F/W (A5x00) | 109962-07 (c,f) | |
2.6 | OBP & SOC+ Fcode | 103346-xx (c) |
Kernel | 105181-33 (g,f) | |
SSD | 105356-20 | |
SES | 105357-04 (h) | |
IB, Socal, sf, & Luxadm | 105375-29 | |
Luxadm man page | 106219-03 | |
Format | 106226-03 | |
MM | 106429-02 (g) | |
ifp (PCI only) | 107280-08 | |
T3 disk and H/W F/W | 109115-12 (c) | |
T3+ disk and H/W F/W | 112276-06 (c) | |
FC100/p Fcode (PCI) | 109399-03 (c) | |
FC100/s Fcode (Sbus) | 109400-03 (c) | |
Disc F/W (A5x00) | 109962-07 (c,f) | |
7 | OBP & SOC+ Fcode | 103346-xx (c) |
Kernel | 106541-23 (f) | |
ifp (PCI only) | 107292-08 (f) | |
SSD | 106541-23 (f) | |
Socal & sf | 107469-09 | |
SES | 107472-02 (h) | |
IB & Luxadm | 107473-07 | |
ifp macros (PCI only) | 107474-01 (f) | |
fsck | 107544-03 (f) | |
Dkio.h & commands.h | 107834-04 (f) | |
adb (leadville) | 108203-05 | |
T3 disc and H/W F/W | 109115-12 (c) | |
T3+ disc and H/W F/W | 112276-06 (c) | |
fctl & fp (leadville) | 109116-04 | |
fcp (leadville) | 109117-05 | |
usoc (leadville) | 109118-02 | |
FC100/p Fcode (PCI) | 109399-03 (c) | |
FC100/s Fcode (Sbus) | 109400-03 (c) | |
Qlc 22xx (leadville) | 109787-04 (f) | |
Disc F/W (A5x00) | 109962-07 (c,f) | |
Qlc 2200 FCode PCI | 111853-01 (c,f) | |
8 | OBP & SOC+ Fcode | 103346-xx (c) |
Kernel | 108528-18 (f) | |
fctl, fc & fp (leadville) | 108982-09 | |
fcip (leadville) | 108983-08 | |
Qlc 22xx (leadville) | 108984-08 | |
T3 disc and H/W F/W | 109115-12 (c) | |
T3+ disc and H/W F/W | 112276-06 (c) | |
SE3300/3310 F/W | 113722-01 | |
FC100/p Fcode (PCI) | 109399-03 (c) | |
FC100/s Fcode (Sbus) | 109400-03 (c) | |
ifp (PCI only) | 109189-04 | |
Socal & sf | 109460-09 | |
SSD | 109524-13 | |
SES | 110614-02 | |
Luxadm | 109529-06 | |
Disc F/W (A5x00) | 109962-07 (c) | |
fctl, fc & fp (STMS) | 111095-12 (f) | |
fcip (STMS) | 111096-05 (f) | |
Qlc 22xx (STMS) | 111097-11 (f) | |
Multi-Path (STMS) | 111412-10 | |
Luxadm (STMS) | 111413-09 (f) | |
cfgadm fp | 111846-05 | |
SAN found. Kit | 111847-05 (s) | |
fopen | 111588-04 | |
Qlc 2200 FCode | 111853-01 (c,f) | |
9 (u) | fctl, fc & fp (leadville) | 113040-03 |
fcip (leadville) | 113041-02 | |
Qlc 22xx (leadville) | 113042-03 | |
T3 disc & H/W F/W | 109115-12 (c,t) | |
T3+ disc & H/W F/W | 112276-06 (c) | |
SE3300/3310 F/W | 113722-01 | |
luxadm | 113043-02 | |
Disc F/W (A5x00) | 109962-07 (t) | |
Multi-Path (STMS) | 113039-02 | |
cfgadm fp | 113044-02 | |
FC100/p FCode(PCI) | 109399-03 (c) | |
FC100/s FCode(Sbus) | 109400-03 (c) | |
Qlc 2200 Fcode | 111853-01 (c,f) | |
SVM |
113026-02 113069-04 113276-01 113282-01 |
The following table shows the Solaris operating system release and the most recent levels of software and firmware for the SPARCstorage Array (SSA).
Minimum Recommended Levels of Software/Firmware -SPARCstorage Array (SSA) | |||
Solaris | Patch | Firmware | SOC Fcode |
---|---|---|---|
2.5.1 (b) |
104708-21 105310-14 (m) |
3.12 | 1.18, 1.33, 1.52 (a) |
2.6 |
105181-33 (g) 105356-20 105375-29 (m) 106219-03 106429-02 (g) |
3.12 | 1.18, 1.33, 1.52 (a) |
7 |
106541-23 (f) 107473-07 (m) 107834-04 (f) |
3.12 | 1.18, 1.33, 1.52 (a) |
8 |
109524-13 109529-06 (m) |
3.12 | 1.18, 1.33, 1.52 (a) |
9 |
|
3.12 | 1.18, 1.33, 1.52 (a) |
The following table shows the Solaris operating system release and the most recent levels of software and firmware for the A5X00/E3500 and T3.
Minimum Recommended Levels of Software/Firmware - StorEdge Array A5X00/E3500 and T3 | ||||||||||
Solaris |
A5x00/E3500 & T3 Patches |
A5x00 IB F/W |
SOC+HA FC100/S |
I/O SysBd |
QLC21xx FC100/P |
QLC22xx (n,p) |
FC-AL Disc F/W |
T3/T3+ Boot |
T3 Loop |
T3 EProm(q) |
---|---|---|---|---|---|---|---|---|---|---|
2.5.1 |
103346-xx(c) 104708-21(b) 105310-14(b) 105324-04(b) 109400-03(c) 109962-07(c,f) |
1.09 | 1.13(c) | 1.8.26(c) | N/A | N/A |
See Tables 1 & 2 (d) |
N/A | N/A | N/A |
2.6 |
103346-xx(c) 105181-33(g) 105356-20 105357-04(h) 105375-29 106219-03 106226-03 106429-02(g) 107280-08 109115-12(c) 112276-06(c) 109399-03(c) 109400-03(c) 109962-07(c,f) |
1.09 | 1.13(c) | 1.8.26(c) | 1.9(c) | N/A |
See Tables 1 & 2 (d) |
1.18.3/ 2.1.3 |
5.02 | 210(q) |
7 |
103346-xx(c) 106541-23(f) 107292-08(f) 106541-23(f) 107469-09 107472-02(h) 107473-07 107474-01(f) 107544-03(f) 107834-04(f) 108203-05 109115-12(c) 112276-06(c) 109116-04 109117-05 109118-02 109399-03(c) 109400-03(c) 109787-04(f) 109962-07(c,f) 111853-01(c,f) |
1.09 | 1.13(c) | 1.8.26(c) | 1.9(c) | 1.13 |
See Tables 1 & 2 (d) |
1.18.3/ 2.1.3 |
5.02 | 210(q) |
8 |
103346-xx(c) 108528-18(f) 108982-09 108983-08 108984-08 109115-12(c) 112276-06(c) 113722-01 109399-03(c) 109400-03(c) 109189-04 109460-09 109524-13 110614-02 109529-06 109962-07(c) 111095-12(f) 111096-05(f) 111097-11(f) 111412-10 111413-09(f) 111846-05 111847-05 111588-04 111853-01(c,f) |
1.09 | 1.13(c) | 1.8.26(c) | 1.9(c) | 1.13 |
See Tables 1 & 2 (d) |
1.18.3/ 2.1.3 |
5.02 | 210(q) |
9 (u) |
113040-03 113041-02 113042-03 109115-12 112276-06 113722-01 113043-02 109962-07(t) 113039-02 113044-02 109399-03(c) 109400-03(c) 111853-01(c,f) 113026-02 113069-04 113276-01 113282-01 |
1.09 | 1.13(c) | 1.8.26(c) | 1.9(c) | 1.13 |
See Tables 1 & 2 (d) |
1.18.3/ 2.1.3 |
5.02 | 210(q) |
The following table shows the Solaris release and the most recent levels of Component Manager, disk management software (for the SSA, A5x00 and T3), and STORtools releases.
Component Manager, Storage Management, NWS Agent and STORtools Software Matrix | ||||||||||
Solaris | SUNW/VRTS Vm (e,r) |
Solstice DiskSuite |
STORtools |
Component Manager(j) |
NWS/RAS Agent |
|||||
---|---|---|---|---|---|---|---|---|---|---|
Vm(e) | Patches(e) | SDS | Patches | STOR | Patches | CM | Patches | NWS/RAS | Patches | |
2.5.1(b) | 2.4(b) | 105208-04 | 4.0 |
102580-18 103421-01 |
3.2 | 108617-xx | N/A | N/A |
2.0 2.1 |
None None |
2.5 | 105463-10 | 4.1 | 104172-24 | |||||||
2.6 | 106606-04 | |||||||||
3.0.4 | 110260-05 | |||||||||
2.6 | 2.4(b) | 105208-04 | 4.1 | 104172-24 |
3.3 |
109090-xx 106219-03 |
1.0 2.0 2.1 2.2 |
108368-01(k) 108390-01(k) 108882-01 108888-01 108944-01(l) None None |
2.0 2.1 |
None 111893-04 |
2.5 | 105463-10 | 4.2 | 106627-17 | |||||||
2.6 | 106606-04 | |||||||||
3.0.4 | 110261-05 | |||||||||
3.1 | 110253-04 | |||||||||
3.1.1 |
110451-06 111122-05 |
|||||||||
3.2 |
111907-06 111904-06 |
|||||||||
7 | 3.0.4 | 110262-05 | 4.2 | 106627-17 |
3.3 |
109090-xx 107473-07 |
1.0 2.0 2.1 2.2 |
108368-01(k) 108391-01(k) 108882-01 108888-01 108944-01(l) None None |
2.0 2.1 |
None 111893-04 |
3.1 | 110254-04 | |||||||||
3.1.1 |
110452-06 111122-05 |
|||||||||
3.2 |
111908-05 111904-06 |
|||||||||
8 | 3.0.4 | 110263-05 | 4.2.1 | 108693-12 |
3.3 4.0.1 4.1 4.2 |
109090-xx 109529-06 111413-09(f) None(r) 111774-01(r) None |
2.0 2.1 2.2 |
108882-01 108888-01 108944-01(l) None None |
2.0 2.1 |
None 111893-04 |
3.1 | 110255-04 | |||||||||
3.1.1 |
111118-07 111122-05 |
|||||||||
3.2 |
111909-06 111904-06 |
|||||||||
9 | 3.0.4 | 110032-02 |
|
|
3.3 4.0.1 4.1 4.2 |
None None(r) None(r) None |
|
|
2.0 2.1 |
None None |
3.1 | None | |||||||||
3.1.1 | None | |||||||||
3.2s9 | 112385-04 |
TABLE 1 (Seagate) | ||
Vendor Part Number |
A5x00 F/W, Patch, Size |
T3 F/W, Patch, Size |
---|---|---|
9 Gbyte Disc | ||
ST19171FC | 7F7x, 109962-07, 1.6"(f) | N/A |
ST39102FC | 1129, 109962-07, 1"(f) | N/A |
ST39103FC | 114B, 109962-07, 1"(f) | N/A |
18 Gbyte Disc | ||
ST118273FC | 9954, 109962-07, 1.6"(f) | N/A |
ST118202FC | N/A | EA29, 109115-12, 112276-06 1.6" |
ST318203FC | 114A, 109962-07, 1"(f) | D94A, 109115-12, 112276-06 1" |
ST318304FC | 0826, 109962-07, 1"(f) | A726, 109115-12, 112276-06 1" |
36 Gbyte Disc | ||
ST136403FC | 114A, 109962-07, 1.6"(f) | D94A, 109115-12, 112276-06 1.6" |
ST336704FC | 0826, 109962-07, 1"(f) | A726, 109115-12, 112276-06 1" |
ST336605FC | 0538, 109962-07, 1"(f) | A438, 109115-12, 112276-06 1" |
72 Gbyte Disc | ||
ST173404FC | N/A | A727, 109115-12, 112276-06 1.6" |
ST373405FC | 0538, 109962-07, 1"(f) | A438, 109115-12, 112276-06 1" |
TABLE 2 (IBM) | ||
Vendor Part Number |
T3 F/W, Patch, Size |
|
---|---|---|
18 Gbyte Disc | ||
DDYF-T18350 | F62Y, None, 1" | |
36 Gbyte Disc | ||
DDYF-T36950 | F62Y, None, 1" |
NOTES:
(a) The 1.18 FCode does not support booting from the SSA. (b) A5x00 is not supported prior to Solaris 2.5.1 (8/97) with maintenance update (MU). Minimum support is Solaris 2.5.1 (8/97) with MU, SEVM2.4 with 105208-03 or SVM 4.1 with 104172-08... Ensure the MU is installed when installing all versions of Solaris 2.5.1 to be used with the A5x00.INTERNAL SUMMARY:
(c) The patches 103346, 109115, 109399, 109400, 109962 and 111853 do not appear in showrev -p. To see the disc firmware revision levels, you may use "luxadm inquiry /dev/rdsk/c[#-#]t*s2 | grep Rev"... The FCode revision level for the SOC+ I/O System Board and the SOC+HA Sbus cards can be checked by "prtconf -vp | grep FCode"... or you can look at the output of the explorer script 2.2.3 or later, for both... (d) See Table(s) 1 & 2. (e) Prior to VRTS 3.0.2, all patches are for SEVM only, the Sun branded version of VRTS. The T3 is not supported prior to 3.0.2... (f) Check the README files for dependencies on other patches... MPxIO/STMS requires Solaris 8, 04/01 or above.....and no, it's not planned to be integrated into a future Solaris 8 update...The product MPxIO has been renamed STMS, StorEdge Traffic Management System... Also, patch 111293 (latest) may be required for Solaris 8 and 9. (g) 105181 is dependent upon 106429-02 or later.... Also, some SSA patches have now been moved into the Kernel patch... (h) Not required for the T3... (j) Does not support the SSA... (k) A5x00 support only... (l) NT patch... (m) This patch is necessary for those who use the LUXADM commands on the SSA... (n) At this time, we have four (4) FC controllers: (1) Amber, 2200 single channel output, 1.13, x6799A (2) Crystal+, 2202 dual channel output, 1.13, x6727A (3) Crystal2A, 2302 2Gb dual channel output, 1.13, x6768A (4) Diamond, 2202 Compact PCI dual channel output, 1.13, x6748A (p) Min requirements are: 2.7 11/99 and leadville patches, or 2.8 6/00 and leadville patches... (q) T3+ has no Eprom code... (r) Obsolete - Use StorTools 4.2. (s) This patch is required by the Brocade switch. (t) This patch should still apply to the Solaris 9 OS even though the Readme does not show such support. (u) Patches 108528-18 and 111293 (latest) show up as Solaris 8 only patches. They may also be required for Solaris 9.
(e) In addition, see http://storage.east/ck/vmtable.html for more VRTS patch details.
Contact Mike Hosrom with questions and updates.