45688 | How to find a disk in a Enterprise [TM] 450 using iostat | 12 Sep 2002 |
Status | Issued |
Description |
If disk-led-assoc is not set up use the follwing procedure to find out where the disk is located in the front of the Enterprise 450.
Find the c#t#d# of the disk giving us problems by using the format command:
# format
Searching for disks...done
AVAILABLE DISK SELECTIONS:
0. c0t0d0 <SUN4.2G cyl 3880 alt 2 hd 16 sec 135>
/pci@1f,4000/scsi@3/sd@0,0
1. c0t1d0 <SUN4.2G cyl 3880 alt 2 hd 16 sec 135>
/pci@1f,4000/scsi@3/sd@1,0
2. c2t0d0 <SUN4.2G cyl 3879 alt 2 hd 16 sec 135> <------ We will use this disk as an example
/pci@6,4000/scsi@4/sd@0,0
3. c2t1d0 <SUN4.2G cyl 3879 alt 2 hd 16 sec 135>
/pci@6,4000/scsi@4/sd@1,0
Specify disk (enter its number):
--------------------------------------------------------------------------------------------------------------------------------
When we know the c#t#d# then use iostat -En to find the serial # of this disk
# iostat -En
c0t0d0 Soft Errors: 0 Hard Errors: 0 Transport Errors: 0
Vendor: FUJITSU Product: MAB3045S SUN4.2G Revision: 1705 Serial No: 9818M30787
Size: 4.29GB <4292075520 bytes>
Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0
Illegal Request: 0 Predictive Failure Analysis: 0
c0t1d0 Soft Errors: 0 Hard Errors: 0 Transport Errors: 0
Vendor: FUJITSU Product: MAB3045S SUN4.2G Revision: 1705 Serial No: 9818M26895
Size: 4.29GB <4292075520 bytes>
Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0
Illegal Request: 0 Predictive Failure Analysis: 0
c1t6d0 Soft Errors: 2 Hard Errors: 0 Transport Errors: 0
Vendor: TOSHIBA Product: XM5701TASUN12XCD Revision: 2395 Serial No:
Size: 0.00GB <0 bytes>
Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0
Illegal Request: 2 Predictive Failure Analysis: 0
c2t0d0 Soft Errors: 1 Hard Errors: 0 Transport Errors: 0
Vendor: SEAGATE Product: ST34371W SUN4.2G Revision: 7462 Serial No: 9716E30027 <---------- Serial #
Size: 4.29GB <4290969600 bytes>
Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0
Illegal Request: 1 Predictive Failure Analysis: 0
c2t1d0 Soft Errors: 1 Hard Errors: 0 Transport Errors: 0
Vendor: QUANTUM Product: VK4550J SUN4.2G Revision: 8600 Serial No: 97146D4554
--------------------------------------------------------------------------------------------------------------------------------
From This serial number 9716E30027 write down the last 5 numbers in this case it is 30027
On every disk in a Enterprise 450 there is a number on the front bracket in this example it is 0020772-9716E30027
Notice that the last numbers match the serial number on the drive. Once you have a match you have found your disk!
___________________________________________________________________________________________
Notice: There are a few Seagate drives where the matching numbers are in the middle of the number given from iostat
Example:c0t3d0 Soft Errors: 0 Hard Errors: 0 Transport Errors: 0
Vendor: SEAGATE Product: ST34371W SUN4.2G Revision: 7462 Serial No: JDE915350PJ46U
The numbers 91535 match the numbers on the drive bracket for this disk.
INTERNAL SUMMARY:This procedure works for Solaris 2.6 and above
you can use this information in conjunction with infodoc #16735 to help set up disk-led-assoc
SUBMITTER: Brian Pryor APPLIES TO: Hardware/Ultra Enterprise/Servers, AFO Vertical Team Docs/Hardware ATTACHMENTS: