InfoDoc ID   Synopsis   Date
47468   Sun Fire[TM] 12K/15K: How to Update the FPROMs on a system board   22 Oct 2002

Status Issued

Description

How to update the FPROMs on a 15K system board

All FPROMs on all system boards must be updated with the sgcpu.flash image using the flashupdate utility.

For SMS 1.1, the image is found in patch 112241-02. 
For SMS 1.2, the image is found in patch 112829-03.             

*** Please read the special instructions found in the patch installation instructions for the above SMS patches. ***

Updating the FPROMs on all the system boards in a domain (example below uses domain 'a')

On the MAIN sc (as sms-svc) run:

mc15k-sc1:sms-svc:4> flashupdate -d a -f  /opt/SUNWSMS/SMS1.2/hostobjs/sgcpu.flash
Current System Board FPROM Information
========================================
CPU at SB0, FPROM 0:
POST   5.13.1   05/31/02 16:36:00
OBP    5.13.1   05/31/02 16:36:00
Ver    5.13.1   05/31/02 16:36:00
CPU at SB0, FPROM 1:
POST   5.13.1   05/31/02 16:36:00
OBP    5.13.1   05/31/02 16:36:00
Ver    5.13.1   05/31/02 16:36:00
CPU at SB1, FPROM 0:
POST   5.13.1   05/31/02 16:36:00
OBP    5.13.1   05/31/02 16:36:00
Ver    5.13.1   05/31/02 16:36:00
CPU at SB1, FPROM 1:
POST   5.13.1   05/31/02 16:36:00
OBP    5.13.1   05/31/02 16:36:00
Ver    5.13.1   05/31/02 16:36:00
CPU at SB2, FPROM 0:
POST   5.13.1   05/31/02 16:36:00
OBP    5.13.1   05/31/02 16:36:00
Ver    5.13.1   05/31/02 16:36:00
CPU at SB2, FPROM 1:
POST   5.13.1   05/31/02 16:36:00
OBP    5.13.1   05/31/02 16:36:00
Ver    5.13.1   05/31/02 16:36:00
CPU at SB16, FPROM 0:
POST   5.13.1   05/31/02 16:36:00
OBP    5.13.1   05/31/02 16:36:00
Ver    5.13.1   05/31/02 16:36:00
CPU at SB16, FPROM 1:
POST   5.13.1   05/31/02 16:36:00
OBP    5.13.1   05/31/02 16:36:00
Ver    5.13.1   05/31/02 16:36:00

Flash Image Information
==========================
POST   5.13.1   05/31/02 16:36:00
OBP    5.13.1   05/31/02 16:36:00
Ver    5.13.1   05/31/02 16:36:00
Do you wish to update the FPROM (yes/no)? y                        

NOTE: You can update the flash PROMs on the system boards, the I/O boards, and the system controller while the Solaris[TM] Operating Environment is active in the domains. You must reboot the domain for the firmware update to take effect.

If you would like to update only ONE system board on the platform, then you specify the board location as follows:

mc15k-sc1:sms-svc:6> flashupdate -f /opt/SUNWSMS/SMS1.2/hostobjs/sgcpu.flash sb0

Current System Board FPROM Information
========================================
CPU at SB0, FPROM 0:
POST   5.13.1   05/31/02 16:36:00
OBP    5.13.1   05/31/02 16:36:00
Ver    5.13.1   05/31/02 16:36:00
CPU at SB0, FPROM 1:
POST   5.13.1   05/31/02 16:36:00
OBP    5.13.1   05/31/02 16:36:00
Ver    5.13.1   05/31/02 16:36:00

Flash Image Information
==========================
POST   5.13.1   05/31/02 16:36:00
OBP    5.13.1   05/31/02 16:36:00
Ver    5.13.1   05/31/02 16:36:00

Do you wish to update the FPROM (yes/no)? y                        

INTERNAL SUMMARY:

SUBMITTER: Elizabeth Fee APPLIES TO: AFO Vertical Team Docs/HAS, Hardware/Sun Fire /15000 ATTACHMENTS: