Description

To redirect input/output to ttya you must be able to get to

the lom prompt through the alarm card. At the lom prompt you

can use the bootmode command to set defaults, or go to the OK

prompt and set input and output device to ttya.

For more information on using the bootmode command,

see infodoc 47563.

To go to the OK prompt from the lom prompt, type

lom> console

ok> setenv input-device ttya

ok> setenv output-device ttya

If you pull the alarm card to try to force the output to

ttya the system will fail post and power down.

To connect to the alarm card, use cable part number 530-1871

and adapter part number 530-2889.