InfoDoc ID | Synopsis | Date | ||
47634 | Getting input/output to ttya on a Netra [TM] 20 | 18 Oct 2002 |
Status | Issued |
Description |
To redirect input/output to ttya you must be able to get to
the lom prompt through the alarm card. At the lom prompt you
can use the bootmode command to set defaults, or go to the OK
prompt and set input and output device to ttya.
For more information on using the bootmode command,
see infodoc 47563.
To go to the OK prompt from the lom prompt, type
lom> console
ok> setenv input-device ttya
ok> setenv output-device ttya
If you pull the alarm card to try to force the output to
ttya the system will fail post and power down.
To connect to the alarm card, use cable part number 530-1871
and adapter part number 530-2889.
INTERNAL SUMMARY:
SUBMITTER: Timothy Heisick APPLIES TO: AFO Vertical Team Docs/Hardware, Hardware/Netra/Netra 20 ATTACHMENTS: