InfoDoc ID | Synopsis | Date | ||
49125 | Netra [TM] 20 LOMlite2 Firmware Update | 9 Jan 2003 |
Status | Issued |
Description |
LOMlite2 Firmware Update
The Netra 20 systems are currently supplied with LOMlite 2 firmware revision 4.4. The firmware must be upgraded to revision 4.5 to enable:
Reporting of the DC PSU status
Correct functionality of a modem when connected to the LOMlite2 serial port
To update the Lights Out Management firmware you must obtain the latest revision of patch 110208 (revision 11 or later) from SunSolve.
The firmware update procedure is described below.
Adding LOMlite2 Patch 110208
Ensure you have the latest revision of Patch 110208 from SunSolve (revision -11 or later).
The LOMlite2 software will not function unless this patch is added.
Confirm the base LOMlite2 firmware version. Type #. to change to the lom> prompt, then run version .
#.
lom> version
LOM version: v4.4-LW2+
LOM checksum: 387e
LOM firmware part# 258-7939-12
Microcontroller: H8S/2148
LOM firmware build Aug 30 2001 18:02:40
Configuration rev. v1.2
lom> console
The LOM firmware version must not be earlier than 4.5.
Type console at the lom> prompt to return to the # prompt.
Confirm that the device node is present (via PROM 4.2.4):
# prtconf -V
OBP 4.2.4 2001/06/13 10:10
# prtconf | grep SUNW,lomv
SUNW,lomv (driver not attached)
Copy the patch to a temporary directory ( /var/tmp ).
Confirm that the patch is present:
# cd /var/tmp
# ls
110208-11.zip
Extract the patch:
# unzip 110208-11.zip
Apply the patch.
# patchadd 110208-11
# reboot
Confirm that the patch has been loaded:
# modinfo | grep lomv
To upgrade the firmware, type:
# lom -G default
When prompted, type C to continue.
This process takes several minutes. Do not turn off the system while the update is progressing.
Press Return to redisplay the Unix prompt.
If the system displays the ok prompt, type go to return to the Unix prompt.
Check the functionality by running the lom -a command:
# lom -a
PSUs:
1 OK
Fans:
1 OK speed 90%
2 OK speed 86%
3 OK speed 75%
LOMlite configuration settings:
serial escape character=#
serial event reporting=default
Event reporting level=fatal, warning & information
Serial security=enabled
Disable watchdog on break=enabled
Automatic return to console=disabled
alarm3 mode=user controlled
firmware version=4.5
firmware checksum=1164
product revision=1.4
product ID=Netra T4
.
<truncated>
.
LOMlite led states:
1 on Power
2 off Fault
3 off Supply A
4 off Supply B
5 on PSU ok
6 off PSU fail
#
The software is now installed and the system is ready for use.
INTERNAL SUMMARY:
SUBMITTER: Ronald Neese APPLIES TO: AFO Vertical Team Docs/Hardware, Hardware/Netra/Netra 20 ATTACHMENTS: