InfoDoc ID | Synopsis | Date | ||
49130 | How to set up RSC console on Sun Fire System | 6 Dec 2002 |
Status | Issued |
Description |
This is applicable on the Sun Fire[TM] 280r, 480, and 880
When using RSC, the system administrator has the option to redirect the console to RSC. This allows the RSC user to enter and exit the system console mode from the RSC shell. If an administrator is using the commands from the current RSC user's guides this can be misleading.
In the current RSC user's guides (2.0,2.1,2.2) the OBP commands to redirect the console to RSC are shown as:
ok diag-output-to rsc
ok setenv input-device rsc
ok setenv output-device rsc
These older commands will not work in redirecting the console to RSC. The following must be used in order for the redirection to take effect:
ok setenv diag-out-console true
ok input-device rsc-console
ok output-device rsc-console
These commands will take effect after the next server reset.
If you are wanting to redirect the console server back to TTYA , you can do the following:
ok setenv diag-out-console false
ok setenv input-device keyboard
ok setenv output-device screen
If the RSC console is the console and RSC has not been fully configured, the RSC card can be pulled from the machine in order to temporarily reset the output to the TTYA port. Once OBP has been started, the parameters will need to be reset appropriately to go to another device until the RSC card has been configured.
INTERNAL SUMMARY:
SUBMITTER: Barian Williams APPLIES TO: AFO Vertical Team Docs/Hardware, Hardware/Sun Fire /280R, Hardware/Sun Fire /V880, Hardware/Sun Fire /V480 ATTACHMENTS: