SRDB ID |
|
Synopsis |
|
Date |
15613 |
|
Mixing SunSwift and DWIS/S cards on Ultra2 |
|
2 Mar 1998 |
Ultra 2 with 2 DWIS/S cards (2-1062A pn, it is a Sbus intlgnt scsi host
adpt DFF and 1 1018A PN, is a ASSY, Sunfastetherner, FWSCSI, install)
panics system with:
Jun 16 11:44:37 infinity unix: WARNING: /sbus@1f,0/QLGC,isp@3,10000 (isp1):
Jun 16 11:44:37 infinity unix: Fatal error, resetting interface
Jun 16 11:44:38 infinity unix: isp1: State dump from isp registers and driver:
Jun 16 11:44:38 infinity unix: isp1: mailboxes(0-5): 0x4000, 0x0, 0x0, 0x1, 0x10, 0xf
Jun 16 11:44:38 infinity unix: isp1: hccr= 0x1, bus_sema= 0x0
Jun 16 11:44:38 infinity unix: isp1: bus: isr= 0xa, icr= 0x0, conf0= 0x2, conf1= 0x7
Jun 16 11:44:38 infinity unix: isp1: cdma: count= 0, addr= 0xfc00a418, status= 0x2, conf= 0x0
Jun 16 11:44:38 infinity unix: isp1: dma: count= 0, addr= 0x0, status= 0x2, conf= 0x0
Jun 16 11:44:38 infinity unix: isp1: risc: R0-R7= 0x0, 0x3870, 0x3870, 0x3872, 0x0, 0x0, 0x30 0x1e
Jun 16 11:44:38 infinity unix: isp1: risc: R8-R15= 0x3ba2, 0x4bd, 0x470, 0x1000, 0x0, 0x3240, 0x10 0x3200
Jun 16 11:44:38 infinity unix: isp1: risc: PSR= 0xd208, IVR= 0x10c3, PCR=0x1001, RAR0=0x30, RAR1=0x3d20
Jun 16 11:44:38 infinity unix: isp1: risc: LCR= 0x1, PC= 0x1793, MTR=0xffff, EMB=0x0, SP=0x3cfe
Jun 16 11:44:38 infinity unix: isp1: request(in/out)= 16/16, response(in/out)= 15/15
Jun 16 11:44:38 infinity unix: isp1: request_ptr(current, base)= 0x50440418 (0x50440018)
Jun 16 11:44:38 infinity unix: isp1: response_ptr(current, base)= 0x504443d8 (0x50444018)
Jun 16 11:44:38 infinity unix: isp1: dvma request_ptr= 0xfc00a018 - 0xfc00e018
Jun 16 11:44:38 infinity unix: isp1: dvma response_ptr= 0xfc00e018 - 0xfc012018
Jun 16 11:44:38 infinity unix: isp1: period/offset: 25/12 25/12 25/12 25/12 25/12 25/12 25/12 25/12
Jun 16 11:44:38 infinity unix: isp1: period/offset: 25/12 25/12 25/12 25/12 25/12 25/12 25/12 25/12
In addition customer had attached to system board 1 DLT 7000 was purchased by
the customer from ATL and 1 FDDI card.
Symptoms are identical to bugid# 4014135:
Bug Id: 4014135
Product: hardware
Category: hardware
Subcategory: controller
Bug/Rfe/Eou: bug
State: dispatched
Development Status:
Synopsis: Mixing SunSwift and DWIS/S cards on Ultra2 causes DWIS/S interface
to reset.
The workaround according to this bug is to remove SunSwift card until
solution is provided. Previous customer was loaned a FSBE card so that he
is able to use the system.
SOLUTION SUMMARY:
The solution is twofold.
1. Change the configuration of the Dwiss boards as follows:
Position 0: SunSwift card (100BaseT/scsi wide single ended)
Position 1: FDDI card
Position 2: Scsi Wide Differential
Position 3: Scsi Wide Differential
2. Add the following to the /etc/system file:
set hme:hme_64bit_enable=0
set fas:fas_enable_sbus64=0
and reboot system with boot -r
NOTE: Be very careful not to bend any board pins as the boards are
moved around, as you might damaged the pins and then get a
hardware parity error.
INTERNAL SUMMARY:
SUBMITTER: Martha A Hernandez-Mayen
APPLIES TO: Hardware/Ultra Workstations, Operating Systems/Solaris/Solaris 2.5.1
ATTACHMENTS: