SRDB ID |
|
Synopsis |
|
Date |
16524 |
|
E450 only shows 4 disks under prtdiag |
|
1 Jun 2000 |
When users run prtdiag -v on the Enterprise 450
fully configured with disks they can only see a max of 4 disks e.g.
Disk LED Status: OK = GREEN ERROR = YELLOW
DISK 18: [EMPTY] DISK 19: [EMPTY]
DISK 16: [EMPTY] DISK 17: [EMPTY]
DISK 14: [EMPTY] DISK 15: [EMPTY]
DISK 12: [EMPTY] DISK 13: [EMPTY]
DISK 10: [EMPTY] DISK 11: [EMPTY]
DISK 8: [EMPTY] DISK 9: [EMPTY]
DISK 6: [EMPTY] DISK 7: [EMPTY]
DISK 4: [EMPTY] DISK 5: [EMPTY]
DISK 2: [OK] DISK 3: [OK]
DISK 0: [OK] DISK 1: [OK]
SOLUTION SUMMARY:
From the OBP prompt:
ok setenv disk-led-assoc 0 x y
where x= 1 to 10 PCI slot where the lowest Ultrascsi cont is installed
where y= 1 to 10 PCI slot where the uppermost Ultrascsi cont is installed
For example, if ctrl cards are in slot 5 and 7 enter the following:
ok setenv disk-led-assoc 0 5 7
if there is only one ctrl installed in slot 5
ok setenv disk-led-assoc 0 5
ok reset
ok boot -r to take effect
Now run prtdiag -v
Disk LED Status: OK = GREEN ERROR = YELLOW
DISK 18: [OK] DISK 19: [OK]
DISK 16: [OK] DISK 17: [OK]
DISK 14: [OK] DISK 15: [OK]
DISK 12: [OK] DISK 13: [OK]
DISK 10: [OK] DISK 11: [OK]
DISK 8: [OK] DISK 9: [OK]
DISK 6: [OK] DISK 7: [OK]
DISK 4: [OK] DISK 5: [OK]
DISK 2: [OK] DISK 3: [OK]
DISK 0: [OK] DISK 1: [OK]
INTERNAL SUMMARY:
APPLIES TO: Hardware, Hardware/Ultra Enterprise/Servers/Enterprise 450, Operating Systems/Solaris/Solaris 2.x, AFO Vertical Team Docs, AFO Vertical Team Docs/Hardware
ATTACHMENTS:
Copyright (c) 1997-2003 Sun Microsystems, Inc.