SRDB ID   Synopsis   Date
16579   Raid Manager (RM6) GUI fails to start when run remotely   16 Nov 2000

Status Issued

Description
When trying to run the RM6 GUI remotely over the network you may get the 
error message :

------------------- TRACEBACK -------------------------
Module "X    " Message   2: file "err.c     " line 453
Module "Dsply" Message   0: file "./xdsply.c" line 102
Module "Err  " Message  -1: file "err.c     " line 1489
-------------------------------------------------------

------------------- TRACEBACK -------------------------
Module "Err  " Message   4: file "err.c     " line 1082
Module "X    " Message   2: file "err.c     " line 453
Module "Dsply" Message   0: file "./xdsply.c" line 102
Module "Err  " Message  -1: file "err.c     " line 1489
-------------------------------------------------------
FATAL ERROR     Failure during error recovery      
SOLUTION SUMMARY:
This is Raid Managers equivalent of the standard "Can't open display" error
message.

You need to check that the DISPLAY environment variable is correctly set and 
that the remote host is allowing you to access it with xhost(1).      
INTERNAL SUMMARY:
       
SUBMITTER: James A Macfarlane APPLIES TO: Storage/RAID Manager, AFO Vertical Team Docs/Storage ATTACHMENTS:


Copyright (c) 1997-2003 Sun Microsystems, Inc.