Raid Manager (RM6) GUI fails to start when run remotely |
|
16 Nov 2000 |
When trying to run the RM6 GUI remotely over the network you may get the
error message :
------------------- TRACEBACK -------------------------
Module "X " Message 2: file "err.c " line 453
Module "Dsply" Message 0: file "./xdsply.c" line 102
Module "Err " Message -1: file "err.c " line 1489
-------------------------------------------------------
------------------- TRACEBACK -------------------------
Module "Err " Message 4: file "err.c " line 1082
Module "X " Message 2: file "err.c " line 453
Module "Dsply" Message 0: file "./xdsply.c" line 102
Module "Err " Message -1: file "err.c " line 1489
-------------------------------------------------------
FATAL ERROR Failure during error recovery
SOLUTION SUMMARY:
This is Raid Managers equivalent of the standard "Can't open display" error
message.
You need to check that the DISPLAY environment variable is correctly set and
that the remote host is allowing you to access it with xhost(1).
INTERNAL SUMMARY:
SUBMITTER: James A Macfarlane
APPLIES TO: Storage/RAID Manager, AFO Vertical Team Docs/Storage