SRDB ID   Synopsis   Date
18036   GBICs are not seen on a E450 & E250   5 Sep 2002

Status Issued

Description
Symptom:

The FC-AL PCI card, FC100/p, Part Number 375-0040 is not seen by the Operation System. 
However the FC-AL PCI card, FC100/p can be seen at the OBP.      

Keywords: hardware, GBIC, fcal, fiber, fibre, Solaris, OBP      
SOLUTION SUMMARY:
Solution:

The FC-AL PCI card is supported in the following machines running Solaris 2.6 or later:

A20 - Ultra 450
A25 - Ultra Enterprise 450
A26 - Enterprise 250

In addition, the fcal packages must be installed from the cdrom 
part number 704-6180 (Fiber Channel PCI FC-AL software) which 
is shipped with the hardware.

Packages are:

  SUNWifp       Sun Fibre Channel Arbitrated Loop Device Driver
  
  SUNWifph      Sun Fibre Channel Arbitrated Loop Driver Header Files

  SUNWvtsfp     SunVTS IFP Controller Test

Below are outlined steps needed to install the drivers.

Insert Fiber Channel PCI FC-AL software cdrom.

        # cd /cdrom/cdrom0

        # cd Product

        # su

        # pkgadd -d .


The following packages are available:
  1  SUNWifp       Sun Fibre Channel Arbitrated Loop Device Driver
                   (sparc) 11.6,REV=1998.03.09.22.27
  2  SUNWifph      Sun Fibre Channel Arbitrated Loop Driver Header Files
                   (sparc) 11.6,REV=1998.03.09.22.27
  3  SUNWvtsfp     SunVTS IFP Controller Test
                   (sparc) 2.1.2,REV=12.98.01.30

Select all packages and install

Reboot system

For more information please reference the Installation Manual, part number 805-3682           
SUBMITTER: Dan Auga APPLIES TO: Hardware, Hardware/Disk Storage Subsystem/StorEdge Disk Array/StorEdge A5000, Operating Systems/Solaris/Solaris 2.6, AFO Vertical Team Docs/Hardware ATTACHMENTS:


Copyright (c) 1997-2003 Sun Microsystems, Inc.