SRDB ID |
|
Synopsis |
|
Date |
18561 |
|
starfire domain panics while booting "Couldn't load stub module" |
|
6 Mar 1999 |
When trying to boot Starfire domain, the following error
appears:
mod_hold_stub: Couldn't load stub module
This looks like Bug ID 4141412. But it is not always the case. We found
in some rare cases that workaround in Bug ID 4141412 is necessary but not
enough.
SOLUTION SUMMARY:
When doing "bringup" on domain, it takes several minutes while all daemons
are initialized. After doing "bringup" wait at least 5 minutes then "boot".
SUBMITTER: Bela Amade
APPLIES TO: Hardware/Ultra Enterprise/Servers/Enterprise 10000, Operating Systems/Solaris/Solaris 2.6
ATTACHMENTS:
Copyright (c) 1997-2003 Sun Microsystems, Inc.