SRDB ID   Synopsis   Date
18561   starfire domain panics while booting "Couldn't load stub module"   6 Mar 1999

Status Issued

Description
When trying to boot Starfire domain, the following error
appears:

mod_hold_stub: Couldn't load stub module 

This looks like Bug ID 4141412. But it is not always the case. We found
in some rare cases that workaround in Bug ID 4141412 is necessary but not
enough.
SOLUTION SUMMARY:
When doing "bringup" on domain, it takes several minutes while all daemons
are initialized. After doing  "bringup" wait at least 5 minutes then "boot". 
SUBMITTER: Bela Amade APPLIES TO: Hardware/Ultra Enterprise/Servers/Enterprise 10000, Operating Systems/Solaris/Solaris 2.6 ATTACHMENTS: