21028 |
|
hpost failure; ERR: libcbs:cbs_check_chain_length:libscan error |
|
22 Oct 1999 |
hpost fails with;
FAIL PROC 9.0: scan integrity fail.
ERR: libcbs:cbs_check_chain_length:libscan error
SOLUTION SUMMARY:
This error occurs if a new system board is added to the E10000.
To resolve, run:
# autoconfig sysboardX (where X is the number of the new system board)
Reboot the SSP.
SUBMITTER: John P. Goggin
APPLIES TO: Hardware/Ultra Workstations
ATTACHMENTS: