SRDB ID   Synopsis   Date
21794   Netra t1 Servers may have second ethernet port disabled   25 Apr 2001

Status Issued

Description
By manufacturing default, the Sun Netra t1 Server OBP env parameter
pcib-probe-list was set to 1,2 which means that only devices 1 and 2 
on the bus are probed and enabled. Thus, only the ebus and the first
ethernet device are enabled.  The second ethernet port device, 3, be-
comes disabled by default. This only occurred in early shipments of 
Netra t1 Servers and was corrected for all subsequent shipments from 
Aug/11/99.

The above mentioned problem can be identified on a Sun Netra t1 Server
from the OK prompt, by typing 'show-devs', if the following error is
displayed:

          Unable to find `/pci@1f,0/pci@1,1/network@3,1'           
SOLUTION SUMMARY:
Correct the disabled second ethernet device, by following the 
recommendation as shown below:

    1. Log in as/su to root

    2. Type the following three lines:

    #eeprom pcib-probe-list=1,2,3
    #eeprom output-device=ttya
    #eeprom input-device=ttya

    3. Reboot
    
              
INTERNAL SUMMARY:
See Field Information notice # I0515-1 for more detail.      
SUBMITTER: Nasser Addi APPLIES TO: Hardware/Disk Storage Subsystem/Telecom Storage, Operating Systems/Solaris/Solaris 2.x, AFO Vertical Team Docs/Network1 ATTACHMENTS: