SRDB ID   Synopsis   Date
21979   E10000 error during "boot net - install" - krtld: error during initial load/link phase   9 Mar 2000

Status Issued

Description
When running "boot net - install" on an E10000 domain, error occurs: 

Rebooting with command: boot net - install
Boot device: /sbus@68,0/SUNW,qfe@1,8c30000  File and args: - install
2ec00 hostname: sc10k-a
domainname: hotline.uk.sun.com
root server: labgw1-183
root directory: /export/fcs/os/2.6_hw598_sparc/Solaris_2.6/Tools/Boot
not found: xdc_send_mondo
not found: xdc_send_mondo
not found: xdc_init_mondo
not found: xdc_init_mondo
krtld: error during initial load/link phase
Fast Instruction Access MMU Miss


SOLUTION SUMMARY:
This is a result of selecting the wrong kernel architecture for E10000 in add_install_client command.
Be sure the architecture selected is sun4u1
SUBMITTER: Cormac Hogan APPLIES TO: Hardware/Ultra Enterprise/Servers/Enterprise 10000 ATTACHMENTS:


Copyright (c) 1997-2003 Sun Microsystems, Inc.