The values of dr-max-mem from eeprom and the kernel do not agree - why? |
|
19 Apr 2000 |
Symptom:
eeprom reports a different value for dr-max-mem than the running kernel.
SOLUTION SUMMARY:
Resolution:
Such a situation is possible if the value of dr-max-mem has been changed
using eeprom, but the domain has yet to be rebooted. For example, a
system is booted with DR enabled. While the domain is up and running,
eeprom dr-max-mem=0 is executed. This updates the eeprom files, but
will not be reflected in the kernel until the next reboot.
SUBMITTER: Charles Price
APPLIES TO: Hardware/Ultra Enterprise/Servers/Enterprise 10000, Operating Systems/Solaris/Solaris 2.6