Symptom: 
eeprom reports a different value for dr-max-mem than the running kernel. 
SOLUTION SUMMARY:
Resolution: 
Such a situation is possible if the value of dr-max-mem has been changed 
using eeprom, but the domain has yet to be rebooted. For example, a
system is booted with DR enabled. While the domain is up and running, 
eeprom dr-max-mem=0 is executed. This updates the eeprom files, but
will not be reflected in the kernel until the next reboot. 
SUBMITTER: Charles Price APPLIES TO: Hardware/Ultra Enterprise/Servers/Enterprise 10000, Operating Systems/Solaris/Solaris 2.6 ATTACHMENTS: