SRDB ID | Synopsis | Date | ||
22647 | netcon_server fails to start after upgrade to SSP 3.1.1: syslog: VerExec: ERR: VerExecApp.cc, 261: netcon_server error | 15 Feb 2001 |
Status | Issued |
Description |
After upgrading a 3.1 SSP to SSP 3.1.1, netcon_server fails to start with the following error message:
syslog: VerExec: ERR: VerExecApp.cc, 261: netcon_server error:
ps -ef | grep netcon shows no netcon and no netcon_server
SOLUTION SUMMARY:
This problem can be resolved by one of two methods:
Method 1
Check that the OS version in
$SSPVAR/.ssp_private/domain_config
file is 5.x not 2.x
Method 2
Create the following link from 2 to 5 in:
/opt/SUNWssp/release/Ultra-Enterprise-10000
ln -s 5 2
drwxr-xr-x 3 root bin 512 Sep 27 09:50 .
drwxr-xr-x 3 root bin 512 Sep 20 1999 ..
lrwxrwxrwx 1 root other 1 Sep 27 09:50 2 -> 5
drwxr-xr-x 5 root bin 512 Sep 20 1999 5
INTERNAL SUMMARY:
SUBMITTER: Dennis McDonald APPLIES TO: Hardware/Ultra Enterprise/Servers/Enterprise 10000, AFO Vertical Team Docs/HAS ATTACHMENTS: