SRDB ID   Synopsis   Date
22647   netcon_server fails to start after upgrade to SSP 3.1.1: syslog: VerExec: ERR: VerExecApp.cc, 261: netcon_server error   15 Feb 2001

Status Issued

Description

After upgrading a 3.1 SSP to SSP 3.1.1, netcon_server fails to start with the following error message:

syslog: VerExec: ERR: VerExecApp.cc, 261: netcon_server error:

ps -ef | grep netcon shows no netcon and no netcon_server

SOLUTION SUMMARY:

This problem can be resolved by one of two methods:

Method 1

Check that the OS version in

$SSPVAR/.ssp_private/domain_config

file is 5.x not 2.x

Method 2

Create the following link from 2 to 5 in:

/opt/SUNWssp/release/Ultra-Enterprise-10000

ln -s 5 2

drwxr-xr-x 3 root bin 512 Sep 27 09:50 .

drwxr-xr-x 3 root bin 512 Sep 20 1999 ..

lrwxrwxrwx 1 root other 1 Sep 27 09:50 2 -> 5

drwxr-xr-x 5 root bin 512 Sep 20 1999 5

INTERNAL SUMMARY:

SUBMITTER: Dennis McDonald APPLIES TO: Hardware/Ultra Enterprise/Servers/Enterprise 10000, AFO Vertical Team Docs/HAS ATTACHMENTS:


Copyright (c) 1997-2003 Sun Microsystems, Inc.