SRDB ID   Synopsis   Date
23181   Sun StorEdge[TM] T3: Symptom:cu Switched Disks in a T300 but Doesn't Remember Their Order   14 Nov 2002

Status Issued

Description

T3array (T300)

cu switched disks in a T300, but doesn't remember their order, as a result the configured T300 will not boot

SOLUTION SUMMARY:

If the disks of a configured T300 have been moved around, the T300 pSOSystem will not boot. the user will be dropped to the EPROM level, which is similar to the OBP level in a server/workstation. At this level, the user will have a ">" prompt.

1. type "boot -s" this command will cause the private area to be rebuilt and will remap the drive positions

2. the T300 will then boot normally.

INTERNAL SUMMARY:

Internal Section

James Beck

Storage/East Technical Support Engineer

james.beck@east.sun.com

SUBMITTER: James Beck APPLIES TO: Hardware/Disk Storage Subsystem/StorEdge Disk Array/StorEdge T3 ATTACHMENTS:


Copyright (c) 1997-2003 Sun Microsystems, Inc.